background image

 

                        

 

I

 is the ON/OFF key for radio and CD

and it is only available in the status of power on. The

first pressing 

 is turning on the radio

the second pressing

 “

 will turn off the radio and turn on

the CD at the same time

and the third pressing“

 

will turn off the radio and CD simultaneous

Ⅱ、

LCD will show present frequency and volume of the radio after turning on the radio

Ⅲ、

In the working of radio, the present radio frequency

 

can be changed by pressing

 “

MIN

”and “

HOUR

Ⅳ、

Pressing the key

 “

SET

 will take out the memorized radio frequency

Pressing the key

SET

  continually will take out the memorized radio frequency from  channels  will be saved at present

channel by pressing this key continually

If none of the channel

 LCD will display “---”

Ⅴ、

Press the key

 “

MEM

 ”

 could memorize the present radio frequency

 Pressing the key

 “

MEM

 continually will memorize the present radio frequency in different channel

 The channel of max is

10

Name of channel is 0-9

Ⅵ、

The volume can be changed by pressing key 

SET

VOL+

”and“

OPEN

11

Operation of Pump

The Button 

, operates pump 1

The Button  

PUMP2

operates  pump 2

The button 

PUMP3

operates pump 3

When Circulation cleaning and heating (including preheating) turn on, circulation pump will be

working automatically.

12

Operation of lasting circulation cleaning

Press the key 

 at any time to turn on or off the lasting circulation cleaning, work mode is like the

preset circulation cleaning.  The surfing pumps and blower work for 30 seconds at every 30 minutes. Ozonizer
works for 15 minutes at every 105 minutes, and repeat in this program.

 Once any surfing pumps or blower pump be start, the ozonizer without working.  The ozonizer can not

work if the circulation pump is without working.

 

IMPORTANT

: Please ensure that the ozone function is not in use whilst bathing in the spa.

13

Operation of spa lights

Press the

 “

” button to 

control the ON/OFF of the LED lights and the Fiber optic lights.

14

Setting the constant Temperature Settings

1

)、

Pressing the

 “

 button 

will start the constant temperature heating.

2

With the setting above, the circulation pump will work automatically.

3

)、

If the temperature is set at 3

5℃,

 when the water temperature reaches or exceeds 3

6℃,

 the heater

9

Содержание SPA-8218

Страница 1: ...HOT TUB Model SPA 8218 OPERATING INSTRUCTION 1 ...

Страница 2: ...t On off MEM Radio channel Memory Lock Surfing pump 1 On off SET Radio channel read Close Surfing pump2 On off Lasting Circulation Cleaning On off Surfing pump3 circulation pump On off Set Circulation Cleaning Time Heating On off Set Pre heating Set Temperature Note The functions listed with blue letters only works on the condition of on off II Function Summary 1 Max with 6 KW heating system set p...

Страница 3: ...massage pumps the heater will stop automatically but if you switch off one pc from the three pcs massage pumps the heater will resume working automatically 20 Configuration for 6kw heater when the heater start and switch on two pcs massage pumps the heater will stop automatically but if you switch off one pc from the three pcs massage pumps the heater will resume working automatically 21 Massage p...

Страница 4: ...automatically after 6 seconds without pressing any buttons 4 Set pre circulation cleaning In the pre set mode circulation will be automatic once per day The display will show clearly whether circulation is in action or not See following Fig 5 6 AM AM Fig 5 Circulation cleaning off Fig 6 Circulation cleaning on When setting the Circulation cleaning the display must be in the Power off status and th...

Страница 5: ...his procedure continue to the next setting 4 If all settings have been correctly set Press for confirmation the system will quit this mode automatically press key to clear settings and exit Notice 1 All the setting of Circulation cleaning must be set on Power OFF status 2 Circulation PUMP and OZONE are not working while setting the circulation cleaning 5 Set preheating if required Only one pre hea...

Страница 6: ...eat On 图 8 Pre heat Off Pre heating is set when the spa is in the Power off status and the LCD display shows 1 Set preheating 2 Time setting for Preheating 3 Continual time of preheating 4 Preset temperature 5 Finished 6 ...

Страница 7: ...ll show SET on the LCD panel Press button to change the setting temperature The range of temperature setting is 15 40 5 When everything is set correctly press the to confirm the system will quit the pre heating setting mode Notice 1 All setting of preheating must be in Power OFF mode just turn on the spa the LCD will display 2 Please note that it shows on or off on the LCD on means preheating is t...

Страница 8: ...ne works at every 15 minutes During the preheating the Circulation cleaning will be turned off automatically once the preset time is finished or Pressing the key can stop directly 8 Operation to Power ON OFF Pressing the key from power off status to enter the power on status To pressing the in the status of power on to enter the power off status The LCD screen shows the on or off See following Fig...

Страница 9: ...OL and OPEN 11 Operation of Pump The Button operates pump 1 The Button PUMP2 operates pump 2 The button PUMP3 operates pump 3 When Circulation cleaning and heating including preheating turn on circulation pump will be working automatically 12 Operation of lasting circulation cleaning Press the key at any time to turn on or off the lasting circulation cleaning work mode is like the preset circulati...

Страница 10: ...IV Electric parameters 1 Performance index Rated voltage 220V 380V 50Hz Maximum working current 60 A 220V 240V Voltage resistance 1250V 1 minute without penetration Isolative resistance 10MΩ Water resistance grade IPX5 Electric shock resistance first grade 2 Output loading index Heater 220 240VAC 3KW 1 Water pump 220 240VAC 2 2KW 3 Water pump 220 240VAC 750W 2 Air pump 220 240VAC 700W 1 Spa light ...

Страница 11: ...fying that parts are installed in the correct zone and that equipotential bonding is carried out WAR NING 1 DANGER RISK OF ELECTRIC SHOCK Connect only to a circuit protected by a Ground Fault Circuit lnterrupter 2 Grounding is required The unit should be installed by a qualified service representative and ground 3 FOR YOUR SAFETY This product should be installed by a professional service technicia...

Страница 12: ...onater 2 change a fuse 3 check if the cable of the main power is connected with the main box or not Displaied E1 FF in control panel 1 temperature detector be cut off or shortcirculate 2 plug of the temperature detector be nundated by water 1 Connect the temperature detector 2 Change a new temperature detector being incapable of activate water pump and water pump icon flashing 1 water not achieve ...

Страница 13: ...13 ...

Страница 14: ...14 ...

Страница 15: ...15 ...

Отзывы: