***Notice***

i.

When   setting   temperature   is   lower   than   or   equal   with   water
temperature

Even   the   Preheating   is   on,   but   the   circulation   PUMP  and

HEATER are not working

ii.

When the HEATER is “I” type frame

The power of circulation PUMP must

reach 750W

Otherwise the heater won’t work due to not enough water

pressure to drive pressure switch.

iii.

Conditions   meet   the   above   “2”

and   the   HEATER   is   still   not

working

Please short the line of water pressure switch

7

Circulation-cleaning

When the current time is as same as the presetting time, the preset is 

 and the tub is filled with

water, the circulation cleaning will start, the circulation pump works at the same.. The LCD shows the countdown

time. All the surfing pumps and blower will work for 30 seconds at every 30 minutes. The Ozone works at every
15 minutes

.

During the preheating, the Circulation cleaning will be turned off automatically once the preset time is

finished. or Pressing the

 “

key can stop directly.

8

Operation to Power ON/ OFF

Pressing the key

 “

” from “power-off” status to enter the “power-on” status. To pressing the

 in the

status of “power-on” to enter the “power-off” status. The LCD screen shows the on or off.  See following Fig.9-10

AM

OFF

   

AM

OFF

Fig.9

OFF

              Fig.10

ON

9

Temperature setting

Under the status of “Power-on” can setting temperature. 

It will add 1 centigrade by press “

” each time

the

temperature will be added continually till reach 40 centigrade(106 Fahrenheit ) by

 press “

” without stop.

Press “

” again

and the  

temperature is show  

15

℃(59  Fahrenheit) 。

The range of adjustment is

15~40

℃(59~106 Fahrenheit)。

10

Operation Radio & CD

AM

PUMP3

Fig.11

Radio frequency is 105.2 MHZ

Save the present frequency to channel 3 (Save channel) 

or Exchange the frequency form channel 3 to the present (Searching channel)

8

Содержание SPA-8218

Страница 1: ...HOT TUB Model SPA 8218 OPERATING INSTRUCTION 1 ...

Страница 2: ...t On off MEM Radio channel Memory Lock Surfing pump 1 On off SET Radio channel read Close Surfing pump2 On off Lasting Circulation Cleaning On off Surfing pump3 circulation pump On off Set Circulation Cleaning Time Heating On off Set Pre heating Set Temperature Note The functions listed with blue letters only works on the condition of on off II Function Summary 1 Max with 6 KW heating system set p...

Страница 3: ...massage pumps the heater will stop automatically but if you switch off one pc from the three pcs massage pumps the heater will resume working automatically 20 Configuration for 6kw heater when the heater start and switch on two pcs massage pumps the heater will stop automatically but if you switch off one pc from the three pcs massage pumps the heater will resume working automatically 21 Massage p...

Страница 4: ...automatically after 6 seconds without pressing any buttons 4 Set pre circulation cleaning In the pre set mode circulation will be automatic once per day The display will show clearly whether circulation is in action or not See following Fig 5 6 AM AM Fig 5 Circulation cleaning off Fig 6 Circulation cleaning on When setting the Circulation cleaning the display must be in the Power off status and th...

Страница 5: ...his procedure continue to the next setting 4 If all settings have been correctly set Press for confirmation the system will quit this mode automatically press key to clear settings and exit Notice 1 All the setting of Circulation cleaning must be set on Power OFF status 2 Circulation PUMP and OZONE are not working while setting the circulation cleaning 5 Set preheating if required Only one pre hea...

Страница 6: ...eat On 图 8 Pre heat Off Pre heating is set when the spa is in the Power off status and the LCD display shows 1 Set preheating 2 Time setting for Preheating 3 Continual time of preheating 4 Preset temperature 5 Finished 6 ...

Страница 7: ...ll show SET on the LCD panel Press button to change the setting temperature The range of temperature setting is 15 40 5 When everything is set correctly press the to confirm the system will quit the pre heating setting mode Notice 1 All setting of preheating must be in Power OFF mode just turn on the spa the LCD will display 2 Please note that it shows on or off on the LCD on means preheating is t...

Страница 8: ...ne works at every 15 minutes During the preheating the Circulation cleaning will be turned off automatically once the preset time is finished or Pressing the key can stop directly 8 Operation to Power ON OFF Pressing the key from power off status to enter the power on status To pressing the in the status of power on to enter the power off status The LCD screen shows the on or off See following Fig...

Страница 9: ...OL and OPEN 11 Operation of Pump The Button operates pump 1 The Button PUMP2 operates pump 2 The button PUMP3 operates pump 3 When Circulation cleaning and heating including preheating turn on circulation pump will be working automatically 12 Operation of lasting circulation cleaning Press the key at any time to turn on or off the lasting circulation cleaning work mode is like the preset circulati...

Страница 10: ...IV Electric parameters 1 Performance index Rated voltage 220V 380V 50Hz Maximum working current 60 A 220V 240V Voltage resistance 1250V 1 minute without penetration Isolative resistance 10MΩ Water resistance grade IPX5 Electric shock resistance first grade 2 Output loading index Heater 220 240VAC 3KW 1 Water pump 220 240VAC 2 2KW 3 Water pump 220 240VAC 750W 2 Air pump 220 240VAC 700W 1 Spa light ...

Страница 11: ...fying that parts are installed in the correct zone and that equipotential bonding is carried out WAR NING 1 DANGER RISK OF ELECTRIC SHOCK Connect only to a circuit protected by a Ground Fault Circuit lnterrupter 2 Grounding is required The unit should be installed by a qualified service representative and ground 3 FOR YOUR SAFETY This product should be installed by a professional service technicia...

Страница 12: ...onater 2 change a fuse 3 check if the cable of the main power is connected with the main box or not Displaied E1 FF in control panel 1 temperature detector be cut off or shortcirculate 2 plug of the temperature detector be nundated by water 1 Connect the temperature detector 2 Change a new temperature detector being incapable of activate water pump and water pump icon flashing 1 water not achieve ...

Страница 13: ...13 ...

Страница 14: ...14 ...

Страница 15: ...15 ...

Отзывы: