The GTO, Inc. Technical Service Department is open
Monday – Thursday 7:30
A.M
. – 5:30
P.M.
and Friday 8:00
A.M.
- 12:00
P.M.
(Eastern Time)
T
ELEPHONE
(800) 543-GATE
OR
(850) 575-0176
F
AX
(850) 575-8950 • E-mail: [email protected] • www.gtoinc.com
S
YSTEM
T
EST
S
PECIFICATIONS
Transformer:
120 Vac / 60 Hz input
18 Vac / 40 VA output
10 W solar panel: 18-22 Vdc / 600 mA per hour
Battery:
12 Vdc / 7 Ah
Wire:
16 gauge, multi stranded, direct burial
Motor:
12 Vdc 90 rpm with case hardened gears. The motor current range
is 2.5 to 10 A if the gate is in good working order.
Receiver:
5 Vdc / digital communication. ONLY GTO receivers can be
connected to these terminals.
Control board:
Microprocessor driven. Powered by 12 Vdc.
terminal. Then activate the unit and watch the voltmeter. The drop should not be more than 1 volt.
Note: A loose battery terminal will cause the same symptoms that a bad battery will cause. Terminals should
be secure and corrosion free.
Remote control range: This will vary at each installation. (see FCC disclaimer on page 23), but generally varies
from 50 ft. to 100 ft.
• Make sure that the receiver is located above metal fences.
• Moving the receiver even a few inches can change the range of operation.
• Move the receiver as far from the motor as possible to avoid the chance of electrical interference.
• Check or change the battery in the transmitter.