background image

5

Connecting the Range Adjustment Control Board:

Step 9:

 Connect the YELLOW wire from the WAND CABLE to the YELLOW wire from the Range Adjustment 

control board using one of the WIRE NUTS provided. 

Step 10

: Connect the BLACK wire from the Range Adjustment control board to the BLACK BATTERY 

CONNECTOR wire (provided), along with the SHIELD wire from the WAND CABLE (see Step 13 below).

Step 11

: Secure the RANGE ADJUSTMENT CONTROL BOARD inside the gate opener control box. The 

control box has slots on both sides of the top battery compartment for extra control boards, or you can use the 
optional mounting hole.

IMPORTANT:

 DO NOT let exposed wiring or components on the control board make contact with other exposed 

wiring or components.

Potentiometer (POT)

Range Adjustment

Control Board

Wire Nut

Wire Nut

Optional Mounting Hole

YELLOW wire

from SENSOR Cable

YELLOW

BLACK

BLACK BATTERY 

CONNECTOR wire provided

MIN

MAX

Power supply connection: 

Step 12:

  Connect the RED and BLACK control board wires from the opener to the DOUBLE SPADE 

CONNECTORS (provided) as shown on the next page. 

Step 13:

 Using a WIRE NUT, connect the SHIELD wire from the WAND CABLE (along with the BLACK 

wire from the Range Adjustment board) to the BLACK BATTERY CONNECTION wire provided. Using the 
remaining WIRE NUT connect the RED wire from the WAND CABLE to the RED BATTERY CONNECTION 
wire provided.

Step 14:

 Connect these wires to the DOUBLE SPADE CONNECTORS as shown. 

IMPORTANT:

 Be sure to connect both RED leads to the 

same

 DOUBLE SPADE CONNECTOR and both 

BLACK leads to the 

other

 DOUBLE SPADE CONNECTOR. 

You will connect the DOUBLE SPADE 

CONNECTORS to the battery in the next step.

The Range Adjustment Control Board 

can be mounted in slots on either side of 

top battery compartment 

OR

 the mount-

ing hole beneath battery compartment. 

PRO-SW3000/3200XL, PRO-SW4000/4200XL

& PRO-SW2000/2002XL Control Box

The Range Adjustment Control Board 

can be mounted in the slot at the bottom 

OR

 the slot at the bottom right. Both are 

located beneath the circuit board.

PRO-SW1000/2000 & PRO-SL1000/2000

Control Box

Содержание FM139

Страница 1: ...dren WARNING WARNING WAND with 50 100 or 150 feet of Direct Burial Cable Range Adjustment Board Warning Signs 2 Wire Nuts 3 Battery Connection Wires 2 Double Spade Connectors 2 Ty Wraps 4 Wire Clamp WARNING GATE OPENING SENSOR IN USE The Automatic Gate Opener is activated when a vehicle comes within range of the sensor buried along side the driveway and could possibly be activated by a child on a ...

Страница 2: ...est priorities is to provide outstanding technical service to our customers Therefore if you have any questions or require any technical assistance visit www gtopro com or call our toll free line 800 543 1236 for technical support The EXIT WAND you have purchased is designed with some of the most advanced technology available In layman s terms the wand detects a change in the earths magnetic field...

Страница 3: ...n at no charge to the customer if returned freight prepaid to GTO Inc 3121 Hartsfield Road Tallahassee Florida USA 32303 IMPORTANT Call 800 543 1236 for a Return Goods Authorization RGA num ber before returning accessory to factory Products received at the factory without an RGA number will not be accepted Replacement or repaired parts are covered by this warranty for the remainder of the one 1 ye...

Страница 4: ...Identification on cover DOUBLE SPADE CONNECTOR a wire connector which allows the connection of two wires to be connect ed to a single terminal see Parts Identification on cover How the EXIT WAND works When a metal object such as a car truck or motorcycle in motion disturbs the MAGNETIC FIELD around the WAND a signal is sent to the automatic gate opener s control board signaling it to open the gate...

Страница 5: ... from activating the wand due to physical vibrations For Optimum Performance Locate the WAND as far as possible away from power transformers power lines underground gas line and telephone lines Locate the WAND away from general moving traffic to prevent unwanted activation Remember that the WAND detects MAGNETIC DISTURBANCES caused by a vehicle s mass and velocity It is recommended that you run th...

Страница 6: ...trol box to prevent it from being accidently pulled out Step 2 If you are installing the WAND on a PRO SW1000 2000 or PRO SL1000 2000 gate opener use a screwdriver or steel punch to carefully remove the thin plastic knockout disk see illustrations at right at the bottom of the control box If you have a dual gate opener system drill a 7 8 diameter hole at the bottom of the control box and install t...

Страница 7: ...XIT OPEN terminal on the opener control board Connect the BLACK wire from the SENSOR CABLE to one of the COMMON terminals on the opener control board BLUE BLACK RECR GRN BLK RED EXIT SAFETY EDGE CYCLE COMMON LINK Mighty Mule 350 Control Board Connect the BLUE wire from the SENSOR CABLE to the EXIT terminal on the opener control board Connect the BLACK wire from the SENSOR CABLE to one of the COMMO...

Страница 8: ...tion Step 12 Connect the RED and BLACK control board wires from the opener to the DOUBLE SPADE CONNECTORS provided as shown on the next page Step 13 Using a WIRE NUT connect the SHIELD wire from the WAND CABLE along with the BLACK wire from the Range Adjustment board to the BLACK BATTERY CONNECTION wire provided Using the remaining WIRE NUT connect the RED wire from the WAND CABLE to the RED BATTE...

Страница 9: ...ncluded WARNING GATE OPENING SENSOR IN USE The Automatic Gate Opener is activated when a vehicle comes within range of the sensor buried along side the driveway and could possibly be activated by a child on a bicycle tricycle or other metal play equipment 8 5 4 38 REWWARN01 Powering Up the WAND IMPORTANT When the WAND is first powered up it must be undis turbed for 60 seconds to perform the self t...

Страница 10: ...n o Connect the BLUE wire from the WAND to the FREE EXIT ENTRY of the gate opener o Connect the BLACK wire from the WAND to the COMMON GND of the gate opener Range POT board connection o Connect the YELLOW wire from the WAND to the YELLOW wire from the Range Adjustment Board o Connect the BLACK wire from the Range Adjustment Board to a negative input voltage o Turn the POT clockwise to increase ra...

Страница 11: ...4 44 5 mm diameter x 16 5 42 cm long Adjustable range 3 12 feet typical installation Very low power consumption ideal for battery application Troubleshooting Make sure all connections are correct If the WAND is not working 1 Make sure the Range Adjustment is set at maximum range 2 Disconnect the power battery to the WAND 3 Reconnect the power to the WAND and make sure that no metal object or vehic...

Страница 12: ...s or wired keypad It can be programmed to use up to 25 different personal identification number PIN codes This used in combination with the GTO PRO automatic gate lock see automatic gate lock adds an additional layer of security for your property Entry Transmitter RB741 The GTO PRO entry transmitter includes a visor clip and has adjustable code settings This is the standard transmitter included in...