7
Typical Gate Wiring Connection:
•
Reference Leads:
o
RED
=> Input Voltage (+)
o
SHIELD
=> Ground/Common (–)
o
BLACK
=> Relay’s Common
o
BLUE
=> Relay’s Normally Open
o
YELLOW => Remote WAND [Range adjustment potentiometer (POT)]
•
Terminology Definitions:
o
‘FREE EXIT/ENTRY’ is defined as input terminals (2) that upon activation (momentarily connected together) will
cause the gate to run in the open direction only. Note: In most gate openers, one of the two terminals is the ‘COM-
MON/GND’.
•
Power supply connection:
o
DC power supply: (11-36 Vdc)
ß
Connect the positive (+) lead of the power supply to the RED wire.
ß
Connect the negative (-) lead of the power supply to the SHIELD wire.
o
AC power supply: (8-26 Vac)
ß
Connect the power supply to the RED & SHIELD wires. There is no polarity for AC power supply.
•
Relay output connection:
o
Connect the BLUE wire from the WAND to the ‘FREE EXIT/ENTRY’ of the gate opener.
o
Connect the BLACK wire from the WAND to the ‘COMMON/GND’ of the gate opener.
•
Range (POT) board connection:
o
Connect the YELLOW wire from the WAND to the YELLOW wire from the Range Adjustment Board.
o
Connect the BLACK wire from the Range Adjustment Board to a negative input voltage.
o
Turn the POT clockwise to increase range.
o
Turn the POT counter-clockwise to decrease range.
For Installation on Other Brand Gate Openers ...
If you are using the
EXIT WAND
on any other automatic gate opener brand, use the information be-
low for wiring the system. If you do not understand the instructions below, please call GTO’s Techni-
cal Support at 1-800-543-1236.
Input
Voltage (+)
Input
Voltage (–)
Relay Output
Common
Relay Output
Normally Open
Range
Adjustment
Range
Adjustment
Board
Input Voltage
11 - 36 Vdc or
8 - 26 Vac
–
+
Free Exit/Entry
Connections
SENSOR
RED
SHIELD
BLACK
BLACK
BLUE
YELLOW
YELL
OW
Generic Wiring Diagram