background image

 

3 Installation                                                                                         

 

3. 1 Unpacking Inspection 

 

1. Open the packing box of UPS and take it out, visually examine the unit 

for transit damage. 

2. Check against the accessory lists that the accessories of the UPS are 

present. (Refer to Table 9-1). 

3. Make sure the model is what you wanted from the nameplate on the rear 

panel 

4. If the UPS arrives damaged, or there is any missing accessory or other 

question above, please contact the distributor immediately. 

 
 

3. 2 Installation Notes 

 

1. When locating the UPS, make sure there is no hazardous objects such as 

water, inflammable gas, corrosive agents and so on around the UPS, and 

that the installation environment meets the specifications. 

2. The UPS should not be placed on a side. The air inlet port at the front 

panel and the outlet port on the rear panel and two side panels should not 

be blocked so as to ensure good ventilation. 

3. In case if the UPS is unpacked, installed and used at very low 

temperatures, condensations of water drops may appear. It is necessary 

to wait until the UPS fully dried inside out before proceeding to 

installation and use. Otherwise, they may be a risk of electric shock. 

4. Place the UPS near the utility power source outlet which supplies power 

to the UPS. In any emergency, switch off the main input socket, cut off 

the battery voltage input. All power sockets must be connected with 

ground protection. 

 
 
 

 

10 

3. 3 Cable Connection 

 

3.3.1 Connecting Input and Output Cables 

1. Input cable connection 

If the UPS is connected via the power cable, please use a proper socket 

with over current protection, and pay attention to the capacity of the 

socket: over 10A for ZS110-1K(-KS), over 16A for ZS110-2K(-KS) and 

ZS110-3K(-KS). A side of input wiring has been fixed with the UPS, and 

the other side is just need to plug into the input socket. The wiring 

configuration is shown in the following diagram.

                                                                                         

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Figure 3-1 Connection Method of Input   

 

2. Output cable connection   

The output of ZS110-1K(-KS)/ ZS110-2K(-KS)/ ZS110-3K(-KS) all 

available to uses sockets. The total output power shall not exceed 

1kVA/0.8kW, 2kVA/1.6 kW

3kVA/2.4 kW. Simply plug the load power 

cable to the output sockets of UPS to complete connection as shown in 

the following diagram. 

 
 
 
 

Содержание ZS110

Страница 1: ...1 USER MANUAL On Line UPS Model ZS110 1000VA 2000VA 3000VA Uninterruptible Power Supply System 2...

Страница 2: ...Please do not overload the UPS 4 The UPS contains large capacity batteries The case of the UPS must not be opened by untrained personnel Otherwise it may cause electric shock 5 Do not short the posit...

Страница 3: ...pe Model Remark 1kVA ZS110 1K With a 1A internal charger and 3 build in batteries of 12V 7AH 2kVA ZS110 2K With a 1A internal charger and 6 build in batteries of 12V 7AH Standard 3kVA ZS110 3K With a...

Страница 4: ...to precise regulated sine wave AC power In Battery mode it receives energy from the battery through the DC DC converter 2 Product Description 5 Bypass It is very important in the UPS system In the eve...

Страница 5: ...ssary to wait until the UPS fully dried inside out before proceeding to installation and use Otherwise they may be a risk of electric shock 4 Place the UPS near the utility power source outlet which s...

Страница 6: ...ng the battery pack 3 Connect the external battery cable to the battery terminal DO NOT connect the battery socket of the UPS first Otherwise it may cause electric shock Connect the red wire to the te...

Страница 7: ...connection of communication Intelligent Slot It is designed for installing the dry contact card SNMP card and 485 card You can choose for one of them to installed a dry contact card You can utilize m...

Страница 8: ...n Mode UPS Operation Mode contains normal mode battery mode and bypass mode Under the three modes the page showing output voltage and output frequency is the main display page If users need more infor...

Страница 9: ...nected one by one l It recommended that the capacity of the generator should double than UPS 18 5 2 2 Battery Mode When operating in the battery mode the display of main page on the front panel is sho...

Страница 10: ...percent page actual load page input information page and the maximum temperature page Notes When operating in bypass mode the backup function of the UPS is not available and the power used by the load...

Страница 11: ...ly for more than 1 second to 22 power off the UPS If it bas been set up to work in bypass mode by software the bypass indicator will be turned on to indicate that the UPS is working in bypass mode In...

Страница 12: ...nt the UPS must be turned off and disconnected from utility power 2 Metal objects such as rings and watches should be removed 3 Use the screwdriver with insulated handle Tools and other metal objects...

Страница 13: ...f it does not work Please contact the distributor or service center F09 on constantly Beep continuously The charger of the UPS is defective Please contact the distributor or Service center A01 Blink o...

Страница 14: ...er to bypass 0ms Normal mode Battery mode Transfer time 4ms Normal mode Bypass mode Output Crest factor 3 1 Batteries voltage 36VDC 72VDC 96VDC Battery Quantity 3 none 6 none 8 none Battery Type Seale...

Страница 15: ...cessories No Machine 1 Intelligent monitor software CD 1 User Manual 1 Standard Model Serial communication cable 1 Machine 1 Intelligent monitor software CD 1 User Manual 1 External Battery Cable 1 Lo...

Отзывы: