1 Introduction                                                                                 

 

1.

 

1 Description of Commonly Used Symbols 

 

Some or all of the following symbols may be used in this manual and may 

appear in your application process. Therefore, all users should read the 

form carefully and thoroughly. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Symbol & Description

 

Symbol

 

Description

 

 

Caution, danger

 

 

Danger electric shock

 

 

Alternating current (AC)

 

 

Direct current (DC)

 

 

Protective ground

 

 

Recycle

 

 

Do not dispose with ordinary trash

 

 

1. 2 Safety Instructions 

 

1. Read this manual carefully and thoroughly before operation the UPS and 

save this manual properly for future reference. 

2. Do not tear up or shatter the alarm table on the UPS and pay attention to 

it. 

3. Please do not overload the UPS. 

4. The UPS contains large capacity batteries. The case of the UPS must not 

be opened by untrained personnel. Otherwise, it may cause electric 

shock. 

5. Do not short the positive and negative electrodes of battery. Otherwise, it 

may cause electric shock or fire. 

6. Do not plunge or insert any objects into the air vents and other inlets. 

7. Do not store or use the device in the following environment: 

Where there is inflammable gas, corrosive agents or heavy dust 

Where the temperature is very high or low (above 40

 

or below 0

or the humidity is very high(more than 90%) 

Under direct sunlight or close to heating facilities 

Place of strong vibrations 

8. In the event of fire occurring in the vicinity, please use dry powder fire 

extinguishers .The use of liquid fire extinguishing agents may cause 

electric shock. 

Содержание ZS110

Страница 1: ...1 USER MANUAL On Line UPS Model ZS110 1000VA 2000VA 3000VA Uninterruptible Power Supply System 2...

Страница 2: ...Please do not overload the UPS 4 The UPS contains large capacity batteries The case of the UPS must not be opened by untrained personnel Otherwise it may cause electric shock 5 Do not short the posit...

Страница 3: ...pe Model Remark 1kVA ZS110 1K With a 1A internal charger and 3 build in batteries of 12V 7AH 2kVA ZS110 2K With a 1A internal charger and 6 build in batteries of 12V 7AH Standard 3kVA ZS110 3K With a...

Страница 4: ...to precise regulated sine wave AC power In Battery mode it receives energy from the battery through the DC DC converter 2 Product Description 5 Bypass It is very important in the UPS system In the eve...

Страница 5: ...ssary to wait until the UPS fully dried inside out before proceeding to installation and use Otherwise they may be a risk of electric shock 4 Place the UPS near the utility power source outlet which s...

Страница 6: ...ng the battery pack 3 Connect the external battery cable to the battery terminal DO NOT connect the battery socket of the UPS first Otherwise it may cause electric shock Connect the red wire to the te...

Страница 7: ...connection of communication Intelligent Slot It is designed for installing the dry contact card SNMP card and 485 card You can choose for one of them to installed a dry contact card You can utilize m...

Страница 8: ...n Mode UPS Operation Mode contains normal mode battery mode and bypass mode Under the three modes the page showing output voltage and output frequency is the main display page If users need more infor...

Страница 9: ...nected one by one l It recommended that the capacity of the generator should double than UPS 18 5 2 2 Battery Mode When operating in the battery mode the display of main page on the front panel is sho...

Страница 10: ...percent page actual load page input information page and the maximum temperature page Notes When operating in bypass mode the backup function of the UPS is not available and the power used by the load...

Страница 11: ...ly for more than 1 second to 22 power off the UPS If it bas been set up to work in bypass mode by software the bypass indicator will be turned on to indicate that the UPS is working in bypass mode In...

Страница 12: ...nt the UPS must be turned off and disconnected from utility power 2 Metal objects such as rings and watches should be removed 3 Use the screwdriver with insulated handle Tools and other metal objects...

Страница 13: ...f it does not work Please contact the distributor or service center F09 on constantly Beep continuously The charger of the UPS is defective Please contact the distributor or Service center A01 Blink o...

Страница 14: ...er to bypass 0ms Normal mode Battery mode Transfer time 4ms Normal mode Bypass mode Output Crest factor 3 1 Batteries voltage 36VDC 72VDC 96VDC Battery Quantity 3 none 6 none 8 none Battery Type Seale...

Страница 15: ...cessories No Machine 1 Intelligent monitor software CD 1 User Manual 1 Standard Model Serial communication cable 1 Machine 1 Intelligent monitor software CD 1 User Manual 1 External Battery Cable 1 Lo...

Отзывы: