GTE Industrieelektronik GmbH
V3.2UK 2/19
KMG-2000-G
Page 6 of 26
4. Measurement of a Force Sequence
4.1 Carrying Out The Force Measurement
•
Switch on (actuate any button as desired)
After switching on, the “start” display appears for
5 seconds:
During this time the language selection or the
options menu can be selected.
After 5 seconds the device is ready to carry out
force measurements.
The current status of the measured-value
memory is displayed top left, e.g.:
2. Normal measurement
3. Individual measurement
If the current normal measurement No.2 is to be cancelled, then by pressing button F2 it
is possible to switch ahead to normal measurement No.4.
There will then be 3 indivi-dual
measurements available once more
.
•
Initialise measuring
A measuring operation is activated by pressing
button F3. The device is now ready to take meas-
urements. The measuring operation is started if a
force > 20 N is exerted on the test surface. The
force/time measuring operation then runs (for a
measuring period of 5 seconds).
•
Carry out measuring operation
Hold the test area centrically (inner circle) to the
measuring points stipulated in the European draft
standards. The measuring points are specifically
prescribed in relation to the relevant type of gate
construction. (see Appendix).
Once the trigger threshold of 20 N has been
passed, the force is measured over a period of 5
seconds. During this time the message “Measure-
ment - Please wait” is displayed.
StM: 2 SiM:3
Options
F1
New StM
F2
Activate
F3
KMG-2000-G GTE
Options
F1
Language
F2
Exit
F3
StM: 2 SiM:3
Options
F1
New StM
F2
Start: F > 20N
Measurement
Please wait