background image

 

TD-L354P User Manual 

13 

CH2 (9ch) 

Name 

DMX value 

DMX percentage 

Function 

Default 

DMX Value 

Red 

255 

0.00% 

100.00%  No light → Full light 

0(0%) 

 

 

65535 

0.00% 

100.00%  Intensity fade, fine (LSB) 

Green 

255 

0.00% 

100.00%  No light → Full light 

0(0%) 

 

65535 

0.00% 

100.00%  Intensity fade, fine (LSB) 

Blue 

255 

0.00% 

100.00%  No light → Full light 

0(0%) 

 

 

65535 

0.00% 

100.00%  Intensity fade, fine (LSB) 

White 

255 

0.00% 

100.00%  No light → Full light 

0(0%) 

 

65535 

0.00% 

100.00%  Intensity fade, fine (LSB) 

Rainbow Function 

0.00% 

3.50% 

No function 

0(0%) 

10 

39 

3.90% 

15.30% 

Rainbow scene 1 

40 

71 

15.70% 

27.80% 

Rainbow scene 2 

72 

103 

28.20% 

40.40% 

Rainbow scene 3 

104 

135 

40.80% 

52.90% 

Rainbow scene 4 

136 

167 

53.30% 

65.50% 

Rainbow scene 5 

168 

199 

65.90% 

78.00% 

Rainbow scene 6 

200 

231 

78.40% 

90.60% 

Rainbow scene 7 

232 

255 

91.00%  100.00%  Rainbow flow from slow to fast 

Color temperature 

24 

0.00% 

9.40% 

No function 

0(0%) 

25 

35 

9.80% 

13.70% 

3200K 

36 

46 

14.10% 

18.00% 

3400K 

47 

57 

18.40% 

22.40% 

3600K 

58 

68 

22.70% 

26.70% 

3800K 

69 

79 

27.10% 

31.00% 

4000K 

80 

90 

31.40% 

35.30% 

4200K 

91 

101 

35.70% 

39.60% 

4400K 

102 

112 

40.00% 

43.90% 

4600K 

113 

123 

44.30% 

48.20% 

4800K 

124 

134 

48.60% 

52.50% 

5000K 

135 

145 

52.90% 

56.90% 

5200K 

146 

156 

57.30% 

61.20% 

5400K 

157 

167 

61.60% 

65.50% 

5600K 

168 

178 

65.90% 

69.80% 

5800K 

179 

189 

70.20% 

74.10% 

6000K 

190 

200 

74.50% 

78.40% 

6200K 

201 

211 

78.80% 

82.70% 

6400K 

212 

222 

83.10% 

87.10% 

6600K 

223 

233 

87.50% 

91.40% 

6800K 

234 

244 

91.80% 

95.70% 

7000K 

245 

255 

96.10%  100.00%  7200K 

Содержание TUNGDOU TD-L354P

Страница 1: ...LED PAR LIGHT TD L354P User s Manual Guangzhou GTD Lighting Technology Co Ltd Tel 86 20 61808296 Fax 86 20 61812282 http www gtd lighting com ...

Страница 2: ...anies and are hereby acknowledged All non GTD brands and product names are trademarks or registered trademarks of their respective companies GTD and all affiliated companies hereby disclaim any and all liabilities for property equipment building and electrical damages injuries to any persons and direct or indirect economic loss associated with the use or reliance of any information contained withi...

Страница 3: ...Product introduction 6 Installation 7 Clamps installation 7 Device installation 7 Power Control connection 7 Power connection 7 Control connection 8 Testing 8 Control panel 9 Menu structure 错误 未定义书签 DMX protocol 1 Technical specification 14 Cleaning and maintenance 16 Troubleshooting 16 System wiring diagram 17 Spare parts list 17 Appendix 1 18 ...

Страница 4: ... Fire hazard It s essential that the fixture is properly grounded Only qualified personnel should perform electrical connections WARNING Wear protective eyewear Never look directly into the light source Only qualified and certified personnel should perform installation of this fixture and only the original rigging parts brackets included with this fixture should be used for installation Before app...

Страница 5: ...ced to ensure performance of the fixture Disconnect the fixture from power before changing any parts or accessories Make sure that the installation area can hold a minimum point load of 10 times the weight of all installed fixtures clamps cables auxiliary equipment etc Check that the cover clamps and locks are undamaged Certified safety cables must always be used when installing the fixture The fi...

Страница 6: ...accessories and then take out the fixture wrapped in the plastic bag Packing after use 1 Switch off the fixture and wait for at least 5 minutes before disconnecting it from AC power Cool down the fixture for at least 15 minutes before packing 2 Flight case Wrap the fixture in plastic bags Hold it by the handles and then carefully place it inside the flight case along with all the accessories Close...

Страница 7: ...ntroduction 1 LED lens 2 Head cover 3 Arm bracket 4 Cast aluminum back cover 5 Manually adjustable screw 6 Safety cable mounting position 7 Display screen 8 DMX output 9 Power output 10 DMX input 11 Power input 12 Clamp mounting hole ...

Страница 8: ...mp tightly Placed on the floor Hanging on the truss Power Control connection Power connection Connection method L Live Brown wire E Earth Yellow Green bi color wire N Neutral Blue wire The voltage and frequency of the power source must be in compliance with the ones marked on the fixture Please apply series connection when many sets of fixtures are connected to the power source to avoid heavy load...

Страница 9: ...s DMX OUTPUT to the first fixture s DMX INPUT then the first fixture s DMX OUTPUT to the second fixture s DMX INPUT and so on It is recommended not to connect more than 32 units on a single DMX universe On the last fixture s output connect a DMX terminator The terminator is a XLR connector with a W and 120Ω resistor between the pin 2 and pin 3 as shown below Testing Connect the fixture to AC power...

Страница 10: ... ENTER to choose a function and enter into corresponding sub menu Each menu represents a specific function of the fixture Press ENTER to select the specific function and save the changes or enter into the submenu then press UP or DOWN to change the value of the selected function increase or decrease Press MENU to return to the previous menu or exit LED indicators Power on RED power LED indicator o...

Страница 11: ...he Backlight time function EDDY ON OFF Inverted Display SET RDMX ON OFF Allow the console to change the Address DEFA ON OFF Factory reset FANS AUTO HIGH LOW Setting the Fans status Save OFF 1 99M 15M Close the LED light when no signal Ver V1 0 V9 9 Software version Fix CODE CXXX 168 Password of the fine adjustment CH_R CH_G CH_B CH_W XXX 0 255 Editing fine adjustment value STAT R xx xxx Manual con...

Страница 12: ...100 00 No light Full light 0 0 7 0 65535 0 00 100 00 Intensity fade fine LSB 8 Blue 0 255 0 00 100 00 No light Full light 0 0 9 0 65535 0 00 100 00 Intensity fade fine LSB 10 White 0 255 0 00 100 00 No light Full light 0 0 11 0 65535 0 00 100 00 Intensity fade fine LSB 12 Rainbow Function 0 9 0 00 3 50 No function 0 0 10 39 3 90 15 30 Rainbow scene 1 40 71 15 70 27 80 Rainbow scene 2 72 103 28 20 ...

Страница 13: ...program 2 80 99 31 40 38 80 Built in program 3 100 119 39 20 46 70 Built in program 4 120 139 47 10 54 50 Built in program 5 140 159 54 90 62 40 Built in program 6 160 179 62 70 70 20 Built in program 7 180 199 70 60 78 00 Built in program 8 200 219 78 40 85 90 Built in program 9 220 239 86 30 93 70 Built in program 10 240 255 94 10 100 00 Voice control DMX protocol CH2 9 channels CH2 9ch Name DMX...

Страница 14: ...0 Rainbow scene 3 104 135 40 80 52 90 Rainbow scene 4 136 167 53 30 65 50 Rainbow scene 5 168 199 65 90 78 00 Rainbow scene 6 200 231 78 40 90 60 Rainbow scene 7 232 255 91 00 100 00 Rainbow flow from slow to fast 8 Color temperature 0 24 0 00 9 40 No function 0 0 25 35 9 80 13 70 3200K 36 46 14 10 18 00 3400K 47 57 18 40 22 40 3600K 58 68 22 70 26 70 3800K 69 79 27 10 31 00 4000K 80 90 31 40 35 3...

Страница 15: ... program 10 240 255 94 10 100 00 Voice control Technical specification Optical Light source LED 3W RGBW quantity 54pcs Expected average lifetime 50000 hours Beam angle fixed 13 50 peak angle 28 10 peak angle RGBW liner color mixing each ring of LEDs individually controllable Photometric Total Output Lumen 5311 lumens Color temperature 3200K 7200K linear regulation Mixing distance 0 3m Electrical P...

Страница 16: ...0 C to 45 C Startup range 5 F to 113 F 15 C to 45 C Storage range 40 F to 140 F 40 C to 60 C Cooling Passive Humidity 98 Connections AC power 1m 3 28 ft cable with water proof plugs in out DMX data input output 2 x 1m 3 28 ft cable with 3 pin Neutrik IP65 XLR plugs in out Certification and Safety EMC EN 55103 1 2009 EN 55103 2 2009 EN 61000 3 2 2006 A2 2009 EN 61000 3 3 2013 Safety EN 60598 2 17 1...

Страница 17: ... If not call a qualified technician Troubleshoot and correct the problem before switching on the fixture again Any maintenance work should only be carried out by qualified technicians Troubleshooting Problem Possible Cause Suggested Correction No response after connected to A C power Power switch not turned on Turn on power switch Take out the fuse and check if it is blown Locate the blown fuse Re...

Страница 18: ...he drive board s current Reduce LED s brightness Excessive dusts or smudges on the effect assembly focus module and objective lens Follow the instructions stated in this user manual to clean the effect assembly focus module and objective lens Damaged or deformed effect assembly focus module or objective lens Replace the damaged or deformed components System wiring diagram Spare parts list Item P N...

Страница 19: ...TD L354P User Manual 18 Appendix 1 266mm 10 5 275mm 10 8 198mm 7 8 230mm 9 1 ...

Страница 20: ...TD L354P User Manual 19 Notes P N 1502011097A Time March 8 2019 ...

Отзывы: