background image

 

GTD-L654P II User Manual 

15 

Photometric   

 

Cleaning and maintenance 

It is required that the fixture should be kept clean and well maintained to ensure its reliability. Its lifespan mainly depends 

on the working environment and proper operation. Should you have any questions, please consult a technical engineer of 
GTD Lighting.   

Notes 

Damage resulted from dust, smoke, oil or improper use is not covered by warranty.   

Warning 

Disconnect the fixture from AC power, and let it cool down for at least 15 minutes before opening the housing. Make sure 
to  use  a  soft  cloth  to  clean  the  optical  components,  and  be  careful,  as  the  coating  is  easily  scratched.  Do  not  use  any 
organic solvent such as alcohol to clean the reflector mirror, dichroic color filters or housing of the fixture. 

 

If the lens is cracked or otherwise damaged, replace it immediately.   

 

If the LED lamp becomes damaged or deformed in any way it must be replaced. 

 

If the light from the LED lamp appears dim, this normally indicates that it is reaching the end of its life span and 
should be changed at once. Aged LED lamps run to the extremity of their life might explode. 

 

If  fixture  does  not  function,  check  the  fuse  on  the  power  socket  of  the  fixture.  Replace  the  fuse  of  the  same 

specification if it is blown. 

 

The fixture is equipped with thermal-protection device that will switch off the LED lamp in case of overheating. If 
this happens, please check that the fans are not blocked, and clean them if they are dirty. Check whether the fans 
are operational. If not, call a qualified technician. Troubleshoot and correct the problem before switching on the 
fixture again. Any maintenance work should only be carried out by qualified technicians. 

 

Содержание GTD-L654P II

Страница 1: ...LED PAR LIGHT GTD L654P II User s Manual Guangzhou GTD Lighting Technology Co Ltd Tel 86 20 61808296 Fax 86 20 61812282 http www gtd lighting com ...

Страница 2: ...mpanies and are hereby acknowledged All non GTD brands and product names are trademarks or registered trademarks of their respective companies GTD and all affiliated companies hereby disclaim any and all liabilities for property equipment building and electrical damages injuries to any persons and direct or indirect economic loss associated with the use or reliance of any information contained wit...

Страница 3: ...s 5 Product introduction 6 Installation 7 Clamps installation 7 Device installation 7 Power Control connection 7 Power connection 7 Control connection 8 Testing 8 Control panel 9 Menu structure 10 DMX protocol 11 Technical specification 13 Cleaning and maintenance 15 Troubleshooting 16 System wiring diagram 17 Spare parts list 17 Appendix 1 17 ...

Страница 4: ...NG Fire hazard It s essential that the fixture is properly grounded Only qualified personnel should perform electrical connections WARNING Wear protective eyewear Never look directly into the light source Only qualified and certified personnel should perform installation of this fixture and only the original rigging parts brackets included with this fixture should be used for installation Before a...

Страница 5: ...before changing any parts or accessories Make sure that the installation area can hold a minimum point load of 10 times the weight of all installed fixtures clamps cables auxiliary equipment etc Check that the cover clamps and locks are undamaged Certified safety cables must always be used when installing the fixture The fixture is only intended for installation operation and maintenance by qualif...

Страница 6: ...from the top put away the accessories and then take out the fixture wrapped in the plastic bag Packing after use 1 Switch off the fixture and wait for at least 5 minutes before disconnecting it from AC power Cool down the fixture for at least 15 minutes before packing 2 Flight case Wrap the fixture in plastic bags Hold it by the handles and then carefully place it inside the flight case along with...

Страница 7: ...uct introduction 1 LED lens 2 Head cover 3 Arm bracket 4 Cast aluminum back cover 5 Manually adjustable screw 6 Safety cable mounting position 7 Display screen 8 DMX output 9 Power output 10 DMX input 11 Power input 12 Mounting hole ...

Страница 8: ... truss Power Control connection Power connection Connection method L Live Brown wire E Earth Yellow Green bi color wire N Neutral Blue wire The voltage and frequency of the power source must be in compliance with the ones marked on the fixture Please apply series connection when many sets of fixtures are connected to the power source to avoid heavy load to the power source When the voltage is 110V...

Страница 9: ...recommended for longer distance Connect the Console s DMX OUTPUT to the first fixture s DMX INPUT then the first fixture s DMX OUTPUT to the second fixture s DMX INPUT and so on It is recommended not to connect more than 32 units on a single DMX universe On the last fixture s output connect a DMX terminator The terminator is a XLR connector with a W and 120Ω resistor between the pin 2 and pin 3 as...

Страница 10: ...ss ENTER to choose a function and enter into corresponding sub menu Each menu represents a specific function of the fixture Press ENTER to select the specific function and save the changes or enter into the submenu then press UP or DOWN to change the value of the selected function increase or decrease Press MENU to return to the previous menu or exit LED indicators Power on RED power LED indicator...

Страница 11: ...Turn on or off the Backlight time function EDDY ON OFF Inverted Display SET RDMX ON OFF Allow the console to change the Address DEFA ON OFF Factory reset FANS AUTO HIGH LOW Setting the Fans status Save OFF 1 99M 15M Close the LED light when no signal Ver V1 0 V9 9 Software version Fix CODE CXXX 168 Password of the fine adjustment CH_R CH_G CH_B XXX 0 255 Editing fine adjustment value Edit SEPR AUT...

Страница 12: ...Intensity fade fine LSB 6 Green 0 255 0 0 100 0 No light Full light 0 0 7 0 65535 0 0 100 0 Intensity fade fine LSB 8 Blue 0 255 0 0 100 0 No light Full light 0 0 9 0 65535 0 0 100 0 Intensity fade fine LSB 10 Rainbow Function 0 9 0 0 3 5 No function 0 0 10 39 3 9 15 3 Rainbow scene 1 40 71 15 7 27 8 Rainbow scene 2 72 103 28 2 40 4 Rainbow scene 3 104 135 40 8 52 9 Rainbow scene 4 136 167 53 3 65...

Страница 13: ... to fast 128 159 50 2 62 4 Open 160 223 62 7 87 5 Random strobe from slow to fast 224 255 87 8 100 0 Open 2 Intensity 0 255 0 0 100 0 No light Full light 0 0 0 65535 0 0 100 0 Intensity fade fine LSB 3 Red 0 255 0 0 100 0 No light Full light 0 0 0 65535 0 0 100 0 Intensity fade fine LSB 4 Green 0 255 0 0 100 0 No light Full light 0 0 0 65535 0 0 100 0 Intensity fade fine LSB 5 Blue 0 255 0 0 100 0...

Страница 14: ... 157 167 61 6 65 5 5600K 168 178 65 9 69 8 5800K 179 189 70 2 74 1 6000K 190 200 74 5 78 4 6200K 201 211 78 8 82 7 6400K 212 222 83 1 87 1 6600K 223 233 87 5 91 4 6800K 234 244 91 8 95 7 7000K 245 255 96 1 100 0 7200K Technical specification Optical Light source 6W RGB 3 in 1 quantity 54pcs Expected average lifetime 50000 hours Beam angle fixed 20 50 peak angle 41 10 peak angle Photometric Total O...

Страница 15: ...mic effects Pan Tilt movement Manually adjustable Strobe 1 25Hz synchronized pulse effects Dimmer 0 100 16 bit electronic linear dimming Thermal Operating range 14 F to 113 F 10 C to 45 C Startup range 5 F to 113 F 15 C to 45 C Storage range 40 F to 140 F 40 C to 60 C Cooling Passive Humidity 98 Connections AC power 1m 3 28 ft cable with water proof plugs in out DMX data input output 2 x 1m 3 28 f...

Страница 16: ... or housing of the fixture If the lens is cracked or otherwise damaged replace it immediately If the LED lamp becomes damaged or deformed in any way it must be replaced If the light from the LED lamp appears dim this normally indicates that it is reaching the end of its life span and should be changed at once Aged LED lamps run to the extremity of their life might explode If fixture does not funct...

Страница 17: ...e of the fixture Choose the channel mode in Channel setting Channel Mode of the fixture as required by the user Malfunctioning of DMX cannon input output connectors No input output voltage to the main control board of the fixture Troubleshooting the DMX XLR signal plate of the fixture replace the main control board of the fixture LED lamp off There is no signal output to the main control board PWM...

Страница 18: ...04E Switching power supply 1412050008A 1 EDS200 5624 Appendix 1 GTD L654P wiring diagram 5 LED Drive LED Drive LCR0005C 56V 56V Signal 1 3 1 2 5 4 6 3 4 2 5 3 1 2 4 2 1 Signal 风扇 1 4 2 3 5 DMX Signal DMX Signal SDI0104A 2 1 3 Thermal 24V 1 2 24V 3 pin water proof male line 3 pin waterproof female line 6 3 1 2 3 2 1 24V 24V 56V 56V LJB0003C 2 1 Thermal 1 LED 4 6 1 2 3 3 4 2 5 6 5 Power Switching Po...

Страница 19: ...GTD L654P II User Manual 18 Notes P N 1502011025B Time December 5th 2017 ...

Отзывы: