background image

20.

21.

www.gtpower.co.nz

www.gtpower.co.nz

GT7005EFi

Replacing the Battery

Replacement battery should be within the fol-

lowing specifications:

Voltage:

 ≤ 12V  

Capacity:

 ≤ 9~18AH

Dimensions:

 ≤ 181 x 76 x 167mm (LxWxH)

When the engine is running, the battery will 

charge by the charging system on the gener-

ator. If the battery has been stored for a long 

period, it will need to be charged prior to use. 

If using an alternative charging system, the 

charging current should be less than 0.15c 

Amperes (c: battery rated capacity).

Rubber Tape

Battery

1. Unhook the rubber tape.
2. Remove the black cable from the battery 

negative (-) terminal, and then remove the 

red cable from the battery positive (+) ter-

minal.

3. Remove the battery from the battery tray 

and replace with a new one.

4. Reconnect red cable to battery positive (+)

  terminal, and reconnect black cable to bat-

tery negative (-) terminal. 

5. Hook the rubber tape. 

Replacing the Fuse

If the engine can’t be started due to low 

speed of the starter motor, check charging 

fuse or battery voltage. If starter motor does 

not actuate during electric starting, check the 

starting fuse:

1. Remove fuse holder located near battery.
2. Hold and twist the two ends of the fuse 

holder.

3. If the fuse has blown, replace it.
4. Replace the fuse into the holder.

Fuse Specifications

 

Starting fuse: 4A, 250V/120V
Charging fuse: 2A, 250V/125V

Cleaning the Fuel Tank Filter

1. Remove the fuel cap and filter.
2. Clean the filter with solvent.
3. Wipe the filter and insert it.

Содержание GT7005EFi

Страница 1: ...GT7005EFi...

Страница 2: ...a market leading provider of innovative power equipment solutions to a wide range of industries across New Zealand and Australia Key product categories are welding equipment air compressors power gen...

Страница 3: ...Specifications 7 Safety Labels 8 Generator Controls Features 9 Control Panel 9 Control Functions 10 Before Starting the Generator 11 Starting the Generator 14 Generator Use 15 Stopping the Generator 1...

Страница 4: ...damp Never expose the generator to rain snow water spray or standing water while in use Protect the generator from all hazardous weather conditions Moisture or ice can cause a short circuit or other...

Страница 5: ...e fuel as a cleaning agent Store any fuel containers in a well venti lated area away from any combustibles or source of ignition Check for fuel leaks after refuelling Never operate the engine if a fue...

Страница 6: ...nstall one support with two bolts using a 10mm spanner 5 Install the second wheel and support refer to steps 2 and 4 above Assembling the Generator Unpacking the Generator WARNING Always have assistan...

Страница 7: ...L GENERATOR Model GT7005EFi Voltage 230V Frequency 50Hz Current 28 3A Rated Output Power 6 5kVA Maximum Output Power 7 0kVA OTHER SPECIFICATIONS Continuous Running Time 5 5 hours Working Ambient Tempe...

Страница 8: ...8 www gtpower co nz GT7005EFi B C E D Safety Labels The safety labels have specific positions and must be replaced if they are unreadable damaged or missing Fig 1 Safety Labels D E A B C A...

Страница 9: ...Starter Grip Recoil 9 Air Cleaner 10 Choke Lever 11 Muffler 12 Fuel Switch Control Panel 13 Economy Switch 14 Engine Switch 15 Circuit Breaker Switches 16 Operation Indicator Lights 17 Circuit Breaker...

Страница 10: ...flow of fuel OFF Stops fuel flowing to the carburetor ON Allows fuel to flow to the carburetor Closed Choke Lever Closed Fuel Switch ON OFF Starter Grip Recoil 8 Pull the starter grip to manually sta...

Страница 11: ...ll need to be restarted Press and hold the RESET button for one second until the overload indicator light red is off and output indicator light green is on When the generator is not over loaded the RE...

Страница 12: ...o 10 ethyl alcohol unleaded is acceptable Methyl Tertiary Butyl Ether MTBE and unleaded fuel blend max 15 MTBE by volume are approved Avoid getting dirt or water into the fuel tank ALWAYS turn fuel sw...

Страница 13: ...tery positive terminal 2 Connect black wire to battery negative terminal 3 Hook battery belt If a replacement battery is required it should be purchased with the following specifica tions Voltage 12V...

Страница 14: ...llow all safety and warn ing label instructions Electric Starting 1 Turn fuel switch to ON position and wait for 30 seconds for fuel to fill the carbureter Fuel Switch ON OFF 2 Move choke lever to CLO...

Страница 15: ...n The generator must be isolated from mains power via a transfer switch and must comply with the relevant laws and electrical codes WARNING For continuous operation do not ex ceed the rated ouput powe...

Страница 16: ...cator light red doesn t switch off and the output indicator light green doesn t switch on stop the en gine and check the generator Oil Alert System The oil alert system is designed to prevent engine d...

Страница 17: ...ong hours of operation Engine Oil Check Change Change Change Change Air Cleaner Element Check Clean 1 Check Replace Spark Plug Check Adjust Replace Spark Arrester Check Check Check Replace Valve Clear...

Страница 18: ...d federal laws and regulations NOTE Used oil should be put into a sealed container and transported to a service station or recycler Do not throw oil into the trash pour it on the ground or pour it dow...

Страница 19: ...e insulation of the spark plug is cracked or chipped or the electrode is damaged replace the spark plug with a new one 4 Check the electrode gap and set it to the gap shown below 5 Measure the spark p...

Страница 20: ...able from the battery positive ter minal 3 Remove the battery from the battery tray and replace with a new one 4 Reconnect red cable to battery positive terminal and reconnect black cable to bat tery...

Страница 21: ...pe to lift 2 Ensure the generator is secured in the ve hicle WARNING Do not use the generator in the trans port vehicle Avoid direct exposure to the sun when the generator is in the transport vehicle...

Страница 22: ...At this point the piston is coming up on its compression stroke and both the intake and exhaust valves are closed In this position it helps to protect the engine from internal corrosion 6 Make sure t...

Страница 23: ...00 Radio 200 200 Blender 375 500 Sump Pump 1 2 HP 1050 2150 Well Pump 1 2 HP 1000 2100 Household Water Pump 1200 2700 Central Air Conditioner 10 000 BTU 1500 2200 24 000 BTU 3800 5000 32 000 BTU 5000...

Страница 24: ...the generator the owner or service technician must first read and understand this instruction manual and comply with all safety instructions Fail ure to follow all instructions may result in conditio...

Страница 25: ...25 www gtpower co nz GT7005EFi Wiring Diagram...

Страница 26: ...rranty Failure caused by incorrect operation of the prod uct lack of proper care and maintenance of the product external damage external circumstances such as contaminated fuel or poor water supply mo...

Страница 27: ...27 www gtpower co nz GT7005EFi...

Страница 28: ......

Отзывы: