Appendix 1 Warnings 

Limitations of Smoke Detector 

The smoke detector is designed for triggering and initiating 

emergency fire equipments, but it only functions when matching with 

other equipments. Installation of this smoke detector must conform 

to electrical codes and standards in your country. 

The smoke detector cannot work without power.  It cannot work if 

power is cut off for any reason. 

The smoke detector may not sense fire that starts where smoke 

cannot reach it, such as in chimneys, in walls, on roofs, or on the 

other side of closed doors. 

The detector also may not sense a fire on another level of a building. 

Therefore, detectors should be placed on every level of a building. 

All types of smoke detector have limitations. Because fires develop 

in different ways and are often unpredictable in their growth, it is 

impossible to predict which type of detector will provide the earliest 

warning. No types of smoke detector can sense every kind of fire 

every time. Generally speaking, detectors may not warn you about 

fires caused by insufficient safety measures, violent explosions, 

leaking gas, improper storage of flammable materials like diluents 

and other safety hazards, arson or children playing with fire. The 

alarm of a smoke detector used in high velocity environment will be 

delayed due to dilution of smoke by frequent and fast airflow. What’s 

more, the smoke detector has to be maintained frequently because 

there will be more dust contamination. 

The smoke detector cannot last forever. In order to keep the detector 

working in good condition, please maintain the equipment 

continuously according to recommendations from manufacturer and 

HTTP://GSTRU.RU

E-MAIL: [email protected]

Содержание C-9105R

Страница 1: ...HTTP WWW HOMBI RU HTTP GSTRU RU E MAIL hombi hombi ru...

Страница 2: ...iple 4 V Mounting and Wiring 6 1 Ambient Conditions for Installation 6 2 Mounting Height and Position 7 3 Mounting 10 4 Wiring 14 VI Commission 15 VII Cautions 17 VIII Operation 18 1 Reading Informati...

Страница 3: ...and reasonable design attractive appearance flexible adjustment and alignment method it s easy to install and adjust The sensitivity of the detector can be set through hand held programmer in field de...

Страница 4: ...e ability 10 SMT processing technology 11 Attractive and decent appearance III Technical Specification 1 Power Voltage 15VDC 28VDC 2 Power Current Commission current 20mA Standby current 12mA Alarm cu...

Страница 5: ...ire illuminates Red LED and turns off Yellow LED Note In this case it does not mean there is a fire After the obscuration is removed the detector clears fault signal automatically Fire signal has to b...

Страница 6: ...m IV Structure and Operation Principle 1 Appearance of the detector is shown in Fig 1 Fig 1 2 Internal devices of the detector and positions to be glued are shown in Fig 2 Fig 2 To Be Glued To Be Glue...

Страница 7: ...nd judges the collected signals through its microprocessor When the detector is in normal monitoring state the intensity of infrared beam received by the receiving part is steady at a certain level Wh...

Страница 8: ...r in winter and the installer should ensure the detector not affected by these factors If the detector is installed on sustaining rack similar to metal tube make sure the sustaining rack fixed firmly...

Страница 9: ...t accessible by smoke into beam zone The following recommendations are for reference a When space height is not over 5m the detector and reflector should be mounted on the two facing walls 0 5m from t...

Страница 10: ...ht is more than 8m the roof is normally gabled without ceiling the detector and reflector should be mounted on the two facing walls about 8m from the floor ensuring that the vertical distance between...

Страница 11: ...tion Manual The Intelligent Solution 9 Detector Detector Reflector Reflector 7m 8m Fig 6 d For gable structure with space height about 8m the detector and reflector should be mounted on the two facing...

Страница 12: ...building If the detector cannot be mounted northward then place the detector on the west wall For applications where sunlight can reach the detector after reflected please consider mounting a sunshad...

Страница 13: ...the mounting distance between the detector and the reflector is less than 40m but more than 8m the detector type should be set at 53 Refer to Section VIII Operation for detailed setting methods 2 Moun...

Страница 14: ...ion bolts in d Thread the wires through cable entry ensuring the length of wires inside convenient for connection e Fix the detector base on the wall with two 6 plastic expansion bolts and flat washer...

Страница 15: ...rough the wire in hole and the knock off hole ensuring the length of wires inside convenient for connection e Fix the detector base onto the bracket with two M4 10 bolts and flat washers Mounting meth...

Страница 16: ...sion bolts are needed to fix single reflector Mounting size is shown in Fig 11a If four reflectors are needed place them seamlessly as shown in Fig 11b Unit mm Fig 11a Fig 11b 4 Wiring Connect 24VDC p...

Страница 17: ...wiring is finished to ensure the detector work stably VI Commission 1 Steps 1 Take off the protective membrane carefully on the surface of the reflector and of the detector cover Do not scratch or con...

Страница 18: ...the magnet of commission tool close to the zone where marked M until Yellow LED illuminates continuously then remove the commission tool quickly and make sure there is no obstruction on the optical pa...

Страница 19: ...ately and Yellow LED should turn off 4 Failed Detectors During testing repair the failing detectors according to directions in Section IX Troubleshooting and X Maintenance and test again If they fail...

Страница 20: ...ently get original information like sensitivity level and device type Refer to details below Enter I2 C programming mode the screen shows a 0 Press Test the screen shows the address code of the detect...

Страница 21: ...shown Press Clear the screen will show a 0 You can continue with further operation Note The hand held programmer has lock password to prevent non special personnel from modifying some important data 4...

Страница 22: ...it after power on a 24V power off b Working indicators damaged c Transient suppressor VD12 damaged d DiodeVD1 VD2 VD10 VD11 breakdown resulting in short circuit with ground e N1 N2 damaged f The flexi...

Страница 23: ...ponent with problem X Maintenance 1 If the detector gives fault signal after working for a long time first check whether the detector is damaged or not and make sure that it is fixed to the wall or ot...

Страница 24: ...ion Manual The Intelligent Solution 22 XI Accessories Accessories provided with the detector are as follows Four 6 plastic expansion bolts One bracket One IR Light Filter Two M4 10 cross recessed pan...

Страница 25: ...lding All types of smoke detector have limitations Because fires develop in different ways and are often unpredictable in their growth it is impossible to predict which type of detector will provide t...

Страница 26: ...t environments The smoke detector contains electronic parts Even though it s made to last for a long period of time any of these parts could fail at any time Therefore test your smoke detector at leas...

Страница 27: ...ch This warranty shall not apply to any product that is found to have been damaged improperly installed or used in any way not in accordance with the instructions supplied with the product Anybody inc...

Страница 28: ...UK Global System Technology PLC Lion Court Staunton Harold Hall Melbourne Road Ashby de la Zouch Leicestershire England LE65 1RT Tel 44 1283 225 478 Fax 44 1283 220 690 Email info gst uk com www gst...

Отзывы: