- 37 -
PTDT 1000
o
utPut
data
r ate
This menu shows the output data rate defined using the COFDM settings and
the current output data rate.
Bx 4A
34363
(32502)
STUFFING
Number 1 Number 2
34363
(= "Number 1"): Maximum gross output data rate
(
32502
) (= "Number 2"): The current measured gross output data rate.
If the station filter is set correctly, this value is lower than the value of the
"Number 1". The value fluctuates, since the data rates of individual stations
are dynamically modified by the broadcasters.
—> "Number 2" is not displayed in the channel strips "
A
" or
"
B
" at the settings "
OUTROUTE 1=>ASI ASI=>MA
" or
"
2=>ASI ASI=>MB
", for the data rate of the ASI input signal
cannot be measured. The ASI input signal therefore must be built
in such a way so that the output data rate ("Number 1") is not
exceeded.
The data rates of the transport streams built by the cassette can be
measured at the setting "
OUTROUTE ASI=>ASI
" and be displayed
in the respective channel strip.
—> Is the "Number 2" higher than "Number 1" question marks "
??
" ap-
pear in the display. In this case correct the COFDM settings (pages
34 …) or the settings of the station filter (page 27).
Bx 4A
34363
(36906) ??
STUFFING
• Press the
button.
—> The "Substitute signal in the case of an incorrect input signal" –
"
FAILURE
" menu is activated.