- 24 -
STC 4-16 CT ME
f
ilter
200
201
202
203
204
205
209
211
210
206
In the
Filter
menu, in the selection
PASS
Services
you can remove programs/
services with table adjustment from the
data streams of the transponders as
well as modify the TS/ON IDs.
In the selection
Drop PIDs
, PIDs can
be removed (dropped) from the data
streams of the transponders or have
a new address assigned (remapped)
without adapting the tables.
—> For entering/indication of the different IDs the number format can
be set to
hexadecimal
or
decimal
in menu
System > Firmware
.
200
Select displaying the station filter.
201
Herein you can select whether only one line is displayed or all lines are
displayed.
202
Indication of the
output data rate
of the transponder:
used
= current needed output data rate
max
= maximum possible value
hold
= previously achieved peak value
203
The
TS
and
ON IDs
are displayed here. For transponders with uncom-
pressed EIT (Event Information Table), you can change the IDs here.
The first line shows the TS-ID, ON-ID is display below.
• For changes, enter the new IDs in the input fields next to the origin IDs.
—> After changes of TS / ON IDs, the NIT must also be regenerated.
204
In column
Filter
you can individually switch on or off the filter.