background image

Page 1 of 4
©2013 GSW Water Heating

                                     

                                

                                                               

NRGSS00908 12-13

Polaris® High-Efficiency 

Residential Gas Water Heater 

The perfect choice for combi systems

www.gsw-wh.com

Polaris® has a high grade 444 stainless steel tank with brass connections for years of dependable, trouble-free 
service - no anode required.  A submerged combustion chamber with spiral flue provides up to 96% thermal 
efficiency and ultra-low standby heat loss of approximately 1%.

SEALED COMBUSTION WITH WOVEN FIBRE PREMIX BURNER

•  Metal fibre burner is designed for clean combustion in high-intensity blue flame mode. Manufactured of refractory steel 

that resists corrosion. Excellent resistance to thermal and mechanical shock, even at extreme temperatures. Uniform 
combustion provides excellent heat transfer.  

WHISPER QUIET OPERATION

•  Ultra quiet blower and burner minimize noise. Requires 120 volt 60Hz power supply.  Draws 

less than 5 Amps.

POWER/DIRECT VENT USING 2” OR 3” PLASTIC PIPE

•  Direct vents up to 120’ using ULC S636 PVC or CPVC pipe either Thru-the-Wall or Thru-the-

Roof.  Optional concentric vent kit available for use Thru-the-Roof or Wall.

PLUG AND PLAY TECHNOLOGY

•  No special adjustments are required at initial start up. Connect air inlet, exhaust outlet, 

water, electricity, and gas, set the temperature and the system functions properly.

SELF-DIAGNOSTIC CONTROL SYSTEM

•  Three external LED lights indicate operational status of water heater. Microprocessor 

monitors nine critical functions.  An LED troubleshooting light, visible through view port, 
signals heater operation status.

FULL SERVICEABILITY FROM THE FRONT

•  Removal of two front-located access panels exposes all serviceable components.  Modular 

components are easily removed.

ENERGY STAR® QUALIFIED

•  PR100-34-2NV model meets ENERGY STAR® requirements

OTHER FEATURES

•  Thermister Temperature Sensor 
•  24-Volt Thermostat Control
•  Hot Surface Ignition
•  Full Flow Brass Drain Valve
•  Zero Clearance to Combustibles
•  Factory Installed T&P Valve 
•  Factory Provided Condensate Trap
•  Multiple 1” Brass Tank Connections

WARRANTY

•  10 year limited tank warranty
•  1 year parts

Содержание Polaris PR100-34-2NV

Страница 1: ...C PIPE Direct vents up to 120 using ULC S636 PVC or CPVC pipe either Thru the Wall or Thru the Roof Optional concentric vent kit available for use Thru the Roof or Wall PLUG AND PLAY TECHNOLOGY No special adjustments are required at initial start up Connect air inlet exhaust outlet water electricity and gas set the temperature and the system functions properly SELF DIAGNOSTIC CONTROL SYSTEM Three ...

Страница 2: ...wer pushes hot combustion gases through the spiral coil which scrubs theremaining heat from the hot gases 6 As combustion gas exits the bottom of the spiral coil it is barely warm to the touch Up to 96 of the heat from the flame is transferred to the water 7 Combustion gases are vented through ULC S636 plastic pipe 8 Condensation formed by cooled combustion air is captured by a condensate trap and...

Страница 3: ...air handler Air from the home is warmed as it is blown across the coil Warmed air is returned to the home through air ducts With up to 199 000 BTUs Polaris can heat most homes large or small RADIANT HYDRONIC HEAT Polaris works great for homeowners who prefer radiant hydronic heat With radiant floor hydronic systems potable hot water is circulated through tubes under the floor The floor absorbs hea...

Страница 4: ...low NOx less than 40 ng j in the blue flame mode and shall be manufactured of refractory steel resistant to thermal and mechanical shock The gas valve shall be a Honeywell CV1 r1 series gas valve with a matching 45 900 series venturi manifold using a 1 1 air gas ratio The combustion system shall be factory adjusted and require no field adjustment on startup The tank shall be constructed of 444 sta...