SPECIFICATIONS
Polaris® High-Efficiency
Residential Gas Water Heater
The perfect choice for combi systems
PR100-34-2NV
34
100,000
96
129
48-1/2
22
2 OR 3
15-3/4
40-1/2
41
6-1/8
150
PR130-34-2NV
34
130,000
96
168
48-1/2
22
2 OR 3
15-3/4
40-1/2
41
6-1/8
150
PR150-34-2NV
34
150,000
95
192
48-1/2
22
2 OR 3
15-3/4
40-1/2
41
6-1/8
150
PR130-50-2NV
50
130,000
95
166
62-1/2
22
2 OR 3
15-3/4
54-1/2
55
6-1/8
176
For propane, substitute “P” for “N” in the model number. 3” Concentric Vent Part #6911089 or 2” Concentric Vent Part #6911088. Specifications are
subject to change without notice in accordance with our policy of continuous improvement. Input, output and recovery may vary depending upon
air inlet and exhaust outlet installations. Length and number of bends in inlet and outlet pipes may reduce input and output. Consult installation,
operation and service manual for details. Dimensions on all charts shown in inches. *1/2” gas supply line can be used for up to 150,000 BTU units, units
over 150,000 BTUs require a 3/4” gas supply line.
Residential gas-fired water heater(s) shall be a direct/power vent Polaris model ________ as manufactured by American Water Heaters and shall have a 10-year
limited tank warranty and a 1-year limited parts warranty, as outlined in the written warranty. Units shall be designed to burn ________(natural/propane) gas and
be CSA International certified to the latest edition of ANSI standard Z21.10.3/CSA 4.3. Water heater(s) shall have a nominal storage capacity of ______ gallons and
a recovery rate of _____ GPH @ 90°F/50°C rise with a rated input of ______ BTU/Hr. Water heater(s) shall be condensing type with a minimum thermal efficiency
of 95-96%, power vented with ULC S636 pipe. Water heater(s) shall have combined vent capabilities of up to 120’ to the exhaust outlet with up to 120’ to the air
inlet. Water heater(s) shall have a low noise combustion system with a woven fibre steel burner capable of low NOx (less than 40 ng/j) in the blue flame mode and
shall be manufactured of refractory steel, resistant to thermal and mechanical shock. The gas valve shall be a Honeywell CV1-r1 series gas valve with a matching
45.900 series venturi manifold using a 1:1 air/gas ratio. The combustion system shall be factory adjusted and require no field adjustment on startup. The tank
shall be constructed of 444 stainless steel with a submerged combustion chamber and rated for 150 PSI working pressure and 300 PSI test pressure. The tank
shall be surrounded by two inches of non-CFC foam insulation covered by an enamel coated metal jacket. Operating controls shall have a 24-volt integrated
control circuit, an immersed thermistor temperature sensor, a recycling energy cut-off switch, external temperature adjustment, and shall have LED lights that
continuously indicate the operational status of the water heater(s). A microprocessor shall automatically monitor nine critical operating functions and signal the
status of each. A factory installed temperature and pressure relief valve shall be provided on all models. A factory provided water thermostatic tempering valve
shall be provided with all models.
TEMP.
CONTROL
KNOB
HEATING
SYSTEM
OUTLET
HEATING
SYSTEM
RETURN
GAS
SUPPLY
COLD
WATER
INLET
AIR
INLET
EXHAUST
OUTLET
CONDENSATE
DRAIN
CONNECTION
E
F
F
G
AIR
INLET
HOT WATER
OUTLET
GAS
CONN.
HEATING
SYSTEM
TAPS
EXHAUST
OUTLET
COLD
INLET
T&P
VALVE
16-5/8”
3-1/2” DIA.
CONCENTRIC VENT KIT
(OPTIONAL)
6-1/4”
5-3/4”
2” EXHAUST
OUTLET
2” AIR
INLET
HOT WATER OUTLET
HOT WATER OUTLET
TOP VIEW
LEFT VIEW
FRONT VIEW
TEMP.
CONTROL
KNOB
HEATING
SYSTEM
OUTLET
HEATING
SYSTEM
RETURN
GAS
SUPPLY
COLD
WATER
INLET
AIR
INLET
EXHAUST
OUTLET
CONDENSATE
DRAIN
CONNECTION
E
F
F
G
AIR
INLET
HOT WATER
OUTLET
GAS
CONN.
HEATING
SYSTEM
TAPS
EXHAUST
OUTLET
COLD
INLET
T&P
VALVE
16-5/8”
3-1/2” DIA.
CONCENTRIC VENT KIT
(OPTIONAL)
6-1/4”
5-3/4”
2” EXHAUST
OUTLET
2” AIR
INLET
HOT WATER OUTLET
HOT WATER OUTLET
TOP VIEW
LEFT VIEW
FRONT VIEW
MODEL
NUMBER
GAL
CAP.
INPUT
BTU
PER HR.
GPH
RECOVERY
90°F/50°C
RISE
VENT
DIAMETER
T&P
HEIGHT
E
GAS
SUPPLY*
F
THERMAL
EFFICIENCY
APPROX.
SHIP
WEIGHT
(LBS)
1” WATER
CONNECTIONS
C D
EXTERIOR
A B
INTEGRATED