SPECIFICATIONS

Polaris® High-Efficiency 

Residential Gas Water Heater 

The perfect choice for combi systems

  PR100-34-2NV 

34 

100,000 

96 

129 

48-1/2 

22 

2 OR 3 

15-3/4 

40-1/2 

41 

6-1/8 

150

  PR130-34-2NV 

34 

130,000 

96 

168 

48-1/2 

22 

2 OR 3 

15-3/4 

40-1/2 

41 

6-1/8 

150

  PR150-34-2NV 

34 

150,000 

95 

192 

48-1/2 

22 

2 OR 3 

15-3/4 

40-1/2 

41 

6-1/8 

150 

  PR130-50-2NV 

50 

130,000 

95 

166 

62-1/2 

22 

2 OR 3 

15-3/4 

54-1/2 

55 

6-1/8 

176

For propane, substitute “P” for “N” in the model number.  3” Concentric Vent Part #6911089 or 2” Concentric Vent Part #6911088.  Specifications are 

subject to change without notice in accordance with our policy of continuous improvement. Input, output and recovery may vary depending upon 

air inlet and exhaust outlet installations.  Length and number of bends in inlet and outlet pipes may reduce input and output.  Consult installation, 

operation and service manual for details.  Dimensions on all charts shown in inches. *1/2” gas supply line can be used for up to 150,000 BTU units, units 

over 150,000 BTUs require a 3/4” gas supply line.

Residential gas-fired water heater(s) shall be a direct/power vent Polaris model ________ as manufactured by American Water Heaters and shall have a 10-year 

limited tank warranty and a 1-year limited parts warranty, as outlined in the written warranty.  Units shall be designed to burn ________(natural/propane) gas and 

be CSA International certified to the latest edition of ANSI standard Z21.10.3/CSA 4.3.  Water heater(s) shall have a nominal storage capacity of ______ gallons and 

a recovery rate of _____ GPH @ 90°F/50°C rise with a rated input of ______ BTU/Hr.  Water heater(s) shall be condensing type with a minimum thermal efficiency 

of 95-96%, power vented with ULC S636 pipe.  Water heater(s) shall have combined vent capabilities of up to 120’ to the exhaust outlet with up to 120’ to the air 

inlet.  Water heater(s) shall have a low noise combustion system with a woven fibre steel burner capable of low NOx (less than 40 ng/j) in the blue flame mode and 

shall be manufactured of refractory steel, resistant to thermal and mechanical shock.  The gas valve shall be a Honeywell CV1-r1 series gas valve with a matching 

45.900 series venturi manifold using a 1:1 air/gas ratio.  The combustion system shall be factory adjusted and require no field adjustment on startup.   The tank 

shall be constructed of 444 stainless steel with a submerged combustion chamber and rated for 150 PSI working pressure and 300 PSI test pressure.  The tank 

shall be surrounded by two inches of non-CFC foam insulation covered by an enamel coated metal jacket.  Operating controls shall have a 24-volt integrated 

control circuit, an immersed thermistor temperature sensor, a recycling energy cut-off switch, external temperature adjustment, and shall have LED lights that 

continuously indicate the operational status of the water heater(s).  A microprocessor shall automatically monitor nine critical operating functions and signal the 

status of each.  A factory installed temperature and pressure relief valve shall be provided on all models.  A factory provided water thermostatic tempering valve 

shall be provided with all models. 

TEMP. 

CONTROL 

KNOB 

HEATING 

SYSTEM 

OUTLET 

HEATING 

SYSTEM 

RETURN 

GAS 

SUPPLY 

COLD 

WATER 

INLET 

AIR 

INLET 

EXHAUST 

OUTLET 
CONDENSATE 

DRAIN 

CONNECTION 

AIR 

INLET 

HOT WATER  

OUTLET 

GAS 

CONN. 

HEATING 

SYSTEM 

TAPS 

EXHAUST 

OUTLET 

COLD 

INLET 

T&P 

VALVE 

16-5/8” 

3-1/2” DIA. 

CONCENTRIC VENT KIT 

(OPTIONAL) 

6-1/4” 

5-3/4” 

2” EXHAUST 

OUTLET 

2” AIR 

INLET 

HOT WATER  OUTLET 

HOT WATER  OUTLET 

TOP VIEW 

LEFT VIEW 

FRONT VIEW 

TEMP. 

CONTROL 

KNOB 

HEATING 

SYSTEM 

OUTLET 

HEATING 

SYSTEM 

RETURN 

GAS 

SUPPLY 

COLD 

WATER 

INLET 

AIR 

INLET 

EXHAUST 

OUTLET 
CONDENSATE 

DRAIN 

CONNECTION 

AIR 

INLET 

HOT WATER  

OUTLET 

GAS 

CONN. 

HEATING 

SYSTEM 

TAPS 

EXHAUST 

OUTLET 

COLD 

INLET 

T&P 

VALVE 

16-5/8” 

3-1/2” DIA. 

CONCENTRIC VENT KIT 

(OPTIONAL) 

6-1/4” 

5-3/4” 

2” EXHAUST 

OUTLET 

2” AIR 

INLET 

HOT WATER  OUTLET 

HOT WATER  OUTLET 

TOP VIEW 

LEFT VIEW 

FRONT VIEW 

MODEL

NUMBER

GAL

CAP.

INPUT

BTU

PER HR.

GPH

RECOVERY

90°F/50°C 

RISE

VENT

DIAMETER

T&P 

HEIGHT

E

GAS

SUPPLY*

F

THERMAL

EFFICIENCY

APPROX.

SHIP 

WEIGHT 

(LBS)

1” WATER

CONNECTIONS

C                       D

EXTERIOR

            A                      B  

INTEGRATED 

AIR FILTER

Содержание Polaris PR100-34-2NV

Страница 1: ...C PIPE Direct vents up to 120 using ULC S636 PVC or CPVC pipe either Thru the Wall or Thru the Roof Optional concentric vent kit available for use Thru the Roof or Wall PLUG AND PLAY TECHNOLOGY No special adjustments are required at initial start up Connect air inlet exhaust outlet water electricity and gas set the temperature and the system functions properly SELF DIAGNOSTIC CONTROL SYSTEM Three ...

Страница 2: ...wer pushes hot combustion gases through the spiral coil which scrubs theremaining heat from the hot gases 6 As combustion gas exits the bottom of the spiral coil it is barely warm to the touch Up to 96 of the heat from the flame is transferred to the water 7 Combustion gases are vented through ULC S636 plastic pipe 8 Condensation formed by cooled combustion air is captured by a condensate trap and...

Страница 3: ...air handler Air from the home is warmed as it is blown across the coil Warmed air is returned to the home through air ducts With up to 199 000 BTUs Polaris can heat most homes large or small RADIANT HYDRONIC HEAT Polaris works great for homeowners who prefer radiant hydronic heat With radiant floor hydronic systems potable hot water is circulated through tubes under the floor The floor absorbs hea...

Страница 4: ...low NOx less than 40 ng j in the blue flame mode and shall be manufactured of refractory steel resistant to thermal and mechanical shock The gas valve shall be a Honeywell CV1 r1 series gas valve with a matching 45 900 series venturi manifold using a 1 1 air gas ratio The combustion system shall be factory adjusted and require no field adjustment on startup The tank shall be constructed of 444 sta...