Important notes: 

• This MPPT should only be operated with a suitable battery connected.

• To enhance Battery and load protection the use of the MIHV or equivalent is recommended

• Before any maintenance ensure that the panels are disconnected or de-energised. 

• Use only PV Systems with open circuit voltage below 84V

• This equipment must be installed by qualified personnel only and incorrect wiring can cause 

fire, injury or death – GSL will accept no responsibility for MPPT misconnection or misuse.

• Use only 12V or 24V Lead Acid or Lithium batteries and confirm the MPPT settings,

  charge voltages and currents are correct for your battery system – if in any doubt seek 

qualifed advice!

• Use wires suitable for at least 80A, but if wire runs are over 3m then larger wires are 

recommended to limit voltage drop and losses. 

• Install the unit in a dry place out of direct sunlight and away from flammable liquids or gases.

• Battery fuse ( BF ) is always required and must be located as close to the battery as possible, 

its sizing depends on the wire size and load ratings. Typically a 80A 60VDC fuse would do.

• Before connecting the battery always check the battery and PV panel polarity.

• 

Optional Diode 

A suitably heatsinked schottky diode rated at or above 80A 60V (its anode 

connected to the + panel and cathode to the MPPT + input white wire) may be used, see wiring 

diagram. This diode will protect against panel short and block any voltage on the panel but will 

slightly decrease the battery charge current. 

WARNING

• DO NOT Disconnect battery and/or load whilst charger is operating. Disconnect charger 

from the PV first 

• IF the optional Diode is not installed then shorting the panels when the batteries are
  connected may damage the MPPT
• Lithium batteries must have a battery management system with built in under votlage 

and over voltage protection. 

• The lowest Maximum Power Point system voltages are 18V for 12V batteries or 36V for 24V batteries

  to ensure full output power

.

More information https://www.caravansplus.com.au

Содержание MPPT60-1

Страница 1: ... read these instructions before use A simple compact low cost MPPT to efficiently charge lead acid and lithium iron batteries from a wide range of photovoltaic panels 1700W Solar Battery Charger Maximum Power Point Tracker MPPT60 1 R10 PATENT APPLIED FOR 2010901565 More information https www caravansplus com au ...

Страница 2: ...14 5V 29V Sealed 14 2V 28 4V Output Voltage Lithium Iron Phosphate Batteries Maintenance 14 1V 28 2V Saturation 14 8V 29 6V Output power 1700W 60A MAX Quiescent current 0 05A Thermal protection Multilevel Type Dimensions mm 255 X 145 X 67mm Indications LED display OUTPUT STATUS Basic Wiring Instructions Disconnected Connected Panel Panel Battery Battery Optional Diode Note First start up may take ...

Страница 3: ... at dawn then the Maintenance Float Mode is entered and that mode is maintained for the remainder of the day Custom float and absorption voltages and thresholds are possible but minimum orders apply This MPPT has a built in multilevel over temperature protection to improve product reliability while maximising output power availability The maximum continuous output power is 1700W in 24V systems and...

Страница 4: ...t in a dry place out of direct sunlight and away from flammable liquids or gases Battery fuse BF is always required and must be located as close to the battery as possible its sizing depends on the wire size and load ratings Typically a 80A 60VDC fuse would do Before connecting the battery always check the battery and PV panel polarity Optional Diode A suitably heatsinked schottky diode rated at o...

Страница 5: ...hen remove 1 middle rear screw on the back panel bottom middle below fan then slide out bottom cover see Figure 1 3 Locate connector J4 see zoom window in Figure 1 4 Move link on J4 to vented position or Remove link for Lithium batteries see Figures 2 3 4 5 Slide in the cover and fit front panel carefully secure the front panel again with the 5 screws and the 1 rear screw The above procedure can b...

Страница 6: ...ase read these instructions before use 1700W Solar Battery Charger Maximum Power Point Tracker Figure 2 Left Vented Battery Setting Figure 3 Right Sealed Battery Setting Figure 4 Left Lithium Battery Setting More information https www caravansplus com au ...

Страница 7: ... reaches the float stage Q How do PV temperatures affects charge current Temperature increase brings down the PVs maximum power point voltage reducing the MPPTs current gain available In principle at 25C it is possible to achieve 30 gain but at 40C a more realistic average temperature about 20 is still available Q What happens at low PV currents The MPPT will outperform the conventional regulator ...

Страница 8: ... 32 63 48 84 64 42 32 84 64 Grid Connect Panel size no cells in grid 1x18 Cell Grid 10 8 1x48 Cell Grid 28 23 2x48 Cell Grid 56 46 3x48 Cell Grid 84 69 1x52 Cell Grid 31 25 2x52 Cell Grid 62 50 1x54 Cell Grid 32 26 2x54 Cell Grid 64 52 1x60 Cell Grid 36 29 2x60 Cell Grid 72 58 1x72 Cell Grid 44 36 1x96cgsp 65 55 For optimal performance from panel and MPPT please use the following table to determin...