Model:

MCM

     

TROUBLE SHOOTING

•  DIM LCD 

     

Check battery voltage, low battery can cause a dim display. 

     

Very low temperatures can cause a slow reacting and dim display. 

•  THE MCM MENUS DO NOT CORRESPOND TO MANUAL MENUS

     

The MCM may have a later than 102 software revision, check software revision.

•  POWERED MCM BUT ERRATIC OR NO DATA DISPLAYED

     

The D type connector may not be properly plugged to the MPPT or the ribbon 

     

cable may be damaged.

•  MCM IS NOT TURNING ON 

     

Check that the MPPT is powered up, the MPPT led should be on or flashing.

     

Disconnect and reconnect the D type connector to the MPPT.

     

Check ribbon cable for signs of damage.

Product Specifications

Display

LCD 2 X16 CHARACTERS

Dimensions

110mm X 77mmX 35mm

Consumption

0.02A

Voltage Accuracy

+/- 1% FS

Current Accuracy

+/- 5% FS

Connector

D TYPE 9 PIN

Cable Length

1.2M

Warranty Conditions:

 The product is warranted to be free from defects in materials and workmanship under normal use and 

service for a period of 24 months from the date of sale. This warranty covers defective parts and workmanship provided that 

the product is shipped prepaid to the seller within 24 months of purchase of goods. This warranty is limited to the repair or 

replacement (at the manufacturers’ discretion) of parts and shipping prepaid to the original despatch destination. We regret that 

no liability can be accepted for consequential or special damages of any kind howsoever arising in connection with products 

supplied by the seller. This warranty is in lieu of all other warranties expressed or implied. No representative is authorised to 

assume for the seller any other liability in connection with the seller’s products.

Maximum Power 

Point Tracker Monitor

Operating Instructions

Please Read Before Use

Unit 2, 110 Station Road, Seven Hills ,NSW,  2147, Australia

MCM-R5

Содержание MCM

Страница 1: ... gasses Do not use the MCM if the enclosure or wires are damaged MCM Connection First install the MPPT30 2 or MPPT60 2 unit as per their own user manual Confirm that the MPPT is functional via the built in output status led it should be green Plug the MCM via the 9 pin D connector on the MPPT from panel and the system is ready to go The MCM should be on the default screen displaying battery voltag...

Страница 2: ...s to Default Values see default tables ALARM RANGE DEFAULT VALUE Over Temp Alarm 30C 75C 70C BUV Alarm 10V 50V 11V Ampere Hour Alarm 50AH 1000AH 200AH PARAMETER RANGE DEFAULT VALUE LVD 10V 50V 10V DDS 1 HOUR 16 HOURS 6 HOURS Load Control ON OFF OFF Use left side UP and right side DOWN buttons to navigate between or within screens and increment or decre ment selected adjustable parameters Use cente...

Страница 3: ...ENABLE 7H OTemp ENABLE 45C BUV ENABLE 21V AHA ENABLE 200 AH RESET ON BLACK DISPLAY ONLY BLUE COMMENT NOT DISPLAYED RED SELECTABLE OR ADJUSTABLE MCM Menu Diagram Vb 27 3V Temp 25C Ib 10A I 15A AHb 5500 3700 Hours 120H System Set Up GSL V102 DEFAULT SCREEN Maximum Power Point Tracker Monitor Operating Instructions Please Read Before Use MCM R5 ...

Страница 4: ...N Cable Length 1 2M Warranty Conditions The product is warranted to be free from defects in materials and workmanship under normal use and service for a period of 24 months from the date of sale This warranty covers defective parts and workmanship provided that the product is shipped prepaid to the seller within 24 months of purchase of goods This warranty is limited to the repair or replacement a...

Отзывы: