Model:

MCM

Maximum Power 

Point Tracker Monitor

Operating Instructions

Please Read Before Use

The MCM unit unleashes the full potential of the multi award winning 

GSL MPPT Solar Battery Chargers.

Using this simple plug and play option allows a display of the solar 

system parameter as well as alarm settings.

    Safety

  Read all instructions and cautions in the manual before installing and operating the MCM

  There are no user serviceable parts inside the MCM, do not disassemble or try to repair the unit.

  Install the unit in a dry place out of direct sunlight and away from flammable liquids or gasses.

  Do not use the MCM if the enclosure or wires are damaged.

MCM Connection

First install the MPPT30-2 or MPPT60-2 unit as per their own user manual. Confirm that the MPPT is functional 

via the built in output status led, it should be green. Plug the MCM via the 9 pin D connector on the MPPT from 
panel and the system is ready to go. The MCM should be on the default screen displaying battery voltage, 
battery current, load current and temperature.
The optional MCM PC GUI software, enables detailed system information storage and display on spreadsheet 
format as well as remote monitoring and control over the internet. This optional software is available with the 
MCM v200 and higher.

MCM Unit

D9 Connector Cable

Optional:

USB Connector Cable

Unit 2, 110 Station Road, Seven Hills ,NSW,  2147, Australia

MCM-R5

Содержание MCM

Страница 1: ... gasses Do not use the MCM if the enclosure or wires are damaged MCM Connection First install the MPPT30 2 or MPPT60 2 unit as per their own user manual Confirm that the MPPT is functional via the built in output status led it should be green Plug the MCM via the 9 pin D connector on the MPPT from panel and the system is ready to go The MCM should be on the default screen displaying battery voltag...

Страница 2: ...s to Default Values see default tables ALARM RANGE DEFAULT VALUE Over Temp Alarm 30C 75C 70C BUV Alarm 10V 50V 11V Ampere Hour Alarm 50AH 1000AH 200AH PARAMETER RANGE DEFAULT VALUE LVD 10V 50V 10V DDS 1 HOUR 16 HOURS 6 HOURS Load Control ON OFF OFF Use left side UP and right side DOWN buttons to navigate between or within screens and increment or decre ment selected adjustable parameters Use cente...

Страница 3: ...ENABLE 7H OTemp ENABLE 45C BUV ENABLE 21V AHA ENABLE 200 AH RESET ON BLACK DISPLAY ONLY BLUE COMMENT NOT DISPLAYED RED SELECTABLE OR ADJUSTABLE MCM Menu Diagram Vb 27 3V Temp 25C Ib 10A I 15A AHb 5500 3700 Hours 120H System Set Up GSL V102 DEFAULT SCREEN Maximum Power Point Tracker Monitor Operating Instructions Please Read Before Use MCM R5 ...

Страница 4: ...N Cable Length 1 2M Warranty Conditions The product is warranted to be free from defects in materials and workmanship under normal use and service for a period of 24 months from the date of sale This warranty covers defective parts and workmanship provided that the product is shipped prepaid to the seller within 24 months of purchase of goods This warranty is limited to the repair or replacement a...

Отзывы: