GSK983Ta-H/ GSK983Ta-V Turning CNC System Connection Manual
15
13. Connection Method for Brake and System Power-on Control
N
Emergency Stop Control
Z Axis Brake Control
+24V
0V
GS2000T-CA1 Servo CN1
Interface Connection
GSK983Ta-H/V
CNC system
KA0
L
DC24V
AC220V
GS2000T-CA1
Servo Drive
Unit CN1 Plug Leading-out Signal Terminals
GS2000T-CA1
X Axis Servo Drive
Unit CN1 Plug
Servo Drive
Unit
brake output-
HOLD-
KA0
SB1
SB2
KA0
CN1-
42
HOLD
-
CN1-
34
ZSL
CN1-
43
HOLD+
CN1-39
COM+
System
Power
Box
+24
V
X Axis Brake
Control
X Axis Zero
Speed Clamping
Power-on Control
0V
KA1
KA0
Servo drive
unit
zero speed clamping input
Servo Drive
Unit
brake
Power 24V
ZSL
HOLD+
COM+
AC
24V
KA1
0V
+24V
1
2
GSK SJT Servo
Motor Brake Plug
KA
2
Emergency
Stop
Chain
KA
2
KA
2
To I/O unit
X38.4 Emergency stop input
Connect with 0V or 24V
:
When X38.COM is24V
,
0V here
;
When X38.COM is 0V,24V here
。
E
System Power-on Control