5. Insert the auxiliary well lock collar (75) onto the auxiliary control rod (74) and install to the bin flange
using carriage bolts (13) and serrated flange nuts (9).
Figure 3-16
Installing the auxiliary well lock collar to bin flange
9
5/16 in. serrated flange nut
74
Auxiliary control rod
13
5/16 x 3/4 in. carriage bolts
75
Auxiliary well lock collar
6. Insert the lock pin (16) through the auxiliary lock collar (75) and auxiliary control rod (74).
NOTE:
Make sure the auxiliary well gate is completely closed, drill a hole in the auxiliary control rod
(74) using the auxiliary lock collar (75) as drilling guide to insert the lock pin (16).
Figure 3-17
Installing the lock pin
16
Lock pin
75
Auxiliary well lock collar
74
Auxiliary control rod
PNEG-2108
8" and 10" Standard Duty and IW Standard Duty
31