8" and 10" Commercial Vertical Bin Unload Auger
8. Shut Down
Normal Shut Down
1. Make certain that bin well and unloading tubes are empty before stopping the unit.
2. Disconnect and lock out the power source before leaving the work area.
Emergency Shut Down
1. Know how to shut down the auger in case of an emergency.
2. Disconnect and lock out the power source.
3. Close bin well control gates.
4. Clear out as much grain from the auger and hopper as you can.
NOTE:
Never restart when under a full load. Starting unit under load may result in damage to the
machine. Such damage is considered abuse of the equipment.
5. Reconnect and unlock the power source.
6. Gradually clear the auger until there is no grain or obstructions.
Lock Out
1. Always stop and disconnect the power source whenever the operator must leave the work area or
for maintenance of the machinery.
2. Make sure no one can operate the unload auger while the operator is not in the work area.
NOTE:
Use the type of main power disconnect switch that is capable of being locked only in the
off position.
Storage Preparation
1. Close all wells to discharge tube.
2. Be sure the unload tube is empty.
3. Make sure power source is disconnected and locked out.
4. Check to see that all fasteners are secure.