9
I. Tack weld the sides of the mounting plate to the product line surface and double check alignment. Also
from the inside of the chute weld a continuous bead around the 4" diameter clearance hole.
J. Re-install the auger tube an re-verify that the auger tube rotates without interference.
K. Remove the auger tube. Grind and polish the interior welds to sanitary requirements.
L. Re-assemble the sampler auger, auger tube, bearings, o-rings, drive coupling, drive unit, discharge
tee, etc.
3.5 Material Sample Transport Lines
The tubing used to transport material samples must be compatible with the operating environment and the
material sampled. The sampler has a 2" OD "Tri-Clover" type sanitary connection. Using the appropriate
compatible adapters, route the sample to allow material to flow via gravity to a convenient collection point. At that
point the sample line may be connected to a collection jar bracket or a Sample Collection System cabinet.
Make all connections airtight and make sure all interior surfaces of joints are smooth and flush. Any ragged or
raised tube ends will collect dust and debris as well as retard material flow. Air leaks can interfere with the
pressure or vacuum conveying and sampling system. Escaping sample material can contaminate surrounding
atmosphere and equipment.
3.6 Controller Location
A. Use vibration isolation pads when mounting the control enclosure or mount the controller in a vibration-
free location.
B. Unless ordered for severe duty, locate controller so it is protected from water and dust.
C. Unless an explosion-proof rated controller was specifically ordered, DO NOT locate the controller in a
hazardous area.
D. Most applications require that the sampler be in easy view of the controller.