 FFI SCR Replacement Kit Instructions

1. Introduction

Read these Instructions before Installation and Operation

FFI SCR Replacement Control Kit

The FFI SCR Replacement Control Kit is a service replacement package for the discontinued woods SCR 
control boards installed on Farm Fans dryers from 1990 to 2007.

The FFI SCR Replacement Kit supersedes previous SCR kits and contains the necessary parts for 
replacing the following SCR control boards:

1. 415-3621-0 SCR CONTROL 1 HP-WOODS W/54

2. 415-4563-3 SCR CONTROL 1/3 HP-WOODS W/54

3. 415-3019-7 SCR CONTROL 3/4 HP-WOODS

4. 415-2302-8 SCR CONTROL 3/4 HP-WOODS W/54

5. SCR-003 SCR CONTROL KIT WOODS

6. 056-1580-2 SCR MOTOR CONTROL-WOODS

Beginning in 1990, the woods SCR board was installed on all new CMS-H, CMS-J and M-Series dryers. 
As of July, 1992, the woods SCR board was installed on all new CF/AB and CF/SA series dryers.

SCR All HP with Vari-Trol (D04-0551)

SCR All HP without Vari-Trol (D04-0552)

CAUTION

To reduce the risk of electrical shock or damage to electrical components, turn
OFF and lock out the main power supply before performing any service or
maintenance work on the dryer.

Part #

Description

Qty

U/M

098-1026-8

Wrapper, Nylon TY - 3-5/8"

1

EA

D03-0013-BRK DIN Rail Mount Single Comp 3.9"

1

EA

D03-0854

Minarik SCR Drive

1

EA

FH-6999

Insulator, 16 Gauge Insulator Crimp

1

EA

HH-1462

Nut, 16 Gauge Wire

2

EA

PNEG-1712

FFI SCR Replacement Kit

1

EA

WR-16BLK

Wire, 16 Gauge Stranded MTW Black

4

FT

WR-18RED

Wire, 18 Gauge Red Stranded 
120-1032-8

3

FT

WR-18WHT

Wire, 18 Gauge White Stranded

3

FT

WR-18YLW

Wire, 18 Gauge Yellow Stranded

3

FT

GT3-0971

24 Volt Power Supply

1

70-0064

3 Amp Time Delay Fuse

2

E300-1003

5 Amp Fuse TD

2

GT3-1065

8 Amp Fuse MDA

2

Part #

Description

Qty

U/M

098-1026-8

Wrapper, Nylon TY - 3-5/8"

1

EA

D03-0013-BRK DIN Rail Mount Single Comp 3.9"

1

EA

D03-0854

Minarik SCR Drive

1

EA

FH-6999

Insulator, 16 Gauge Insulator Crimp

1

EA

HH-1462

Nut, 16 Gauge Wire

2

EA

PNEG-1712

FFI SCR Replacement Kit

1

EA

WR-16BLK

Wire, 16 Gauge Stranded MTW Black

4

FT

WR-18RED

Wire, 18 Gauge Red Stranded 
120-1032-8

3

FT

WR-18WHT

Wire, 18 Gauge White Stranded

3

FT

WR-18YLW

Wire, 18 Gauge Yellow Stranded

3

FT

D03-0805

Touch Control, 12 VDC Power Supply

1

EA

70-0064

3 Amp Time Delay Fuse

2

E300-1003

5 Amp Fuse TD

2

GT3-1065

8 Amp Fuse MDA

2

Содержание FFI SCR

Страница 1: ...PNEG 1712 FFI SCR Replacement Kit Installation Manual PNEG 1712 Date 05 22 15...

Страница 2: ...nt Kit Instructions All information illustrations photos and specifications in this manual are based on the latest information available at the time of publication The right is reserved to make change...

Страница 3: ...hese Instructions before Installation and Operation 4 Chapter 2 Installation 6 Replacing the Woods Board 6 Vari Trol Power Supply 7 Non Vari Trol Power Supply 8 Chapter 3 Setup Parameters 9 Maximum Po...

Страница 4: ...lock out the main power supply before performing any service or maintenance work on the dryer Part Description Qty U M 098 1026 8 Wrapper Nylon TY 3 5 8 1 EA D03 0013 BRK DIN Rail Mount Single Comp 3...

Страница 5: ...1 Introduction PNEG 1712 FFI SCR Replacement Kit Instructions 5 Figure 1A FFI SCR Replacement Board Figure 1B Woods SCR Board Discontinued...

Страница 6: ...iented as shown in Figure 1A on Page 5 Note that additional holes must be drilled into the mounting surface using a 9 64 drill bit 3 Mount the DIN Rail D03 0013 BRK next to the new SCR board if possib...

Страница 7: ...l S1 3 Connect L1 to wire 27 4 Connect N to wire 2 5 Connect G to ground NOTE It is very important on Vari Trol systems to remove the jumper if present on the back of the Honeywell moisture controller...

Страница 8: ...on Vari Trol Power Supply Install power supply on DIN Rail 1 Connect 12 VDC to SCR terminal S3 2 Connect 12 VDC to SCR terminal S1 3 Connect L1 to wire 27 4 Connect N to wire 2 5 Connect G to ground F...

Страница 9: ...ly M Series dryers were designed to operate with a 175 VDC armature voltage Consult the factory if there is any question regarding these early models Minimum Potentiometer Adjustment Set the SCR speed...

Страница 10: ...3 Setup Parameters 10 PNEG 1712 FFI SCR Replacement Kit Instructions Vari Trol Calibration OUT HI will need to be set to 80 Refer to Figure 3A for instructions Figure 3A...

Страница 11: ...ODUCTS GSI shall not be liable for any direct indirect incidental or consequential damages including without limitation loss of anticipated profits or benefits The sole and exclusive remedy is set for...

Страница 12: ...be carefully followed in all cases Authorities having jurisdiction should be consulted before installations are made 1004 E Illinois St Assumption IL 62510 0020 Phone 1 217 226 4421 Fax 1 217 226 4420...

Отзывы: