PNEG-1712

FFI SCR Replacement Kit

Installation Manual

PNEG-1712

Date: 05-22-15

Содержание FFI SCR

Страница 1: ...PNEG 1712 FFI SCR Replacement Kit Installation Manual PNEG 1712 Date 05 22 15...

Страница 2: ...nt Kit Instructions All information illustrations photos and specifications in this manual are based on the latest information available at the time of publication The right is reserved to make change...

Страница 3: ...hese Instructions before Installation and Operation 4 Chapter 2 Installation 6 Replacing the Woods Board 6 Vari Trol Power Supply 7 Non Vari Trol Power Supply 8 Chapter 3 Setup Parameters 9 Maximum Po...

Страница 4: ...lock out the main power supply before performing any service or maintenance work on the dryer Part Description Qty U M 098 1026 8 Wrapper Nylon TY 3 5 8 1 EA D03 0013 BRK DIN Rail Mount Single Comp 3...

Страница 5: ...1 Introduction PNEG 1712 FFI SCR Replacement Kit Instructions 5 Figure 1A FFI SCR Replacement Board Figure 1B Woods SCR Board Discontinued...

Страница 6: ...iented as shown in Figure 1A on Page 5 Note that additional holes must be drilled into the mounting surface using a 9 64 drill bit 3 Mount the DIN Rail D03 0013 BRK next to the new SCR board if possib...

Страница 7: ...l S1 3 Connect L1 to wire 27 4 Connect N to wire 2 5 Connect G to ground NOTE It is very important on Vari Trol systems to remove the jumper if present on the back of the Honeywell moisture controller...

Страница 8: ...on Vari Trol Power Supply Install power supply on DIN Rail 1 Connect 12 VDC to SCR terminal S3 2 Connect 12 VDC to SCR terminal S1 3 Connect L1 to wire 27 4 Connect N to wire 2 5 Connect G to ground F...

Страница 9: ...ly M Series dryers were designed to operate with a 175 VDC armature voltage Consult the factory if there is any question regarding these early models Minimum Potentiometer Adjustment Set the SCR speed...

Страница 10: ...3 Setup Parameters 10 PNEG 1712 FFI SCR Replacement Kit Instructions Vari Trol Calibration OUT HI will need to be set to 80 Refer to Figure 3A for instructions Figure 3A...

Страница 11: ...ODUCTS GSI shall not be liable for any direct indirect incidental or consequential damages including without limitation loss of anticipated profits or benefits The sole and exclusive remedy is set for...

Страница 12: ...be carefully followed in all cases Authorities having jurisdiction should be consulted before installations are made 1004 E Illinois St Assumption IL 62510 0020 Phone 1 217 226 4421 Fax 1 217 226 4420...