Technical Specification

Power Supply

                      

12 DC

Current consumption    

120mA

Current consumption with load (max)

160mA

Relay Contact Rating

 5 Amps /240V ac

Moisture Resistance

 

 Indoor Use Only

Dimensions  

 

                              

W.

 135mm 

D. 

46mm 

H.

 200mm

Technical Specs - GSD Wi-Plus Controller

Power Supply

                      

12 DC

Current consumption    

110mA

Current consumption with load (max)

145mA

Relay Contact Rating

5 Amps /240V ac

Operating Temperature

- 20  C   to +60  C

Moisture Resistance   

IP 67 ( IP65 on Wi-Bio )

Dimensions  - Flush Mount

 

W.

 87mm 

D. 

21mm 

H.

 119mm

       - Surface Mount  

W.

 87mm 

D. 

35mm 

H.

 119mm

Technical Specs - Wi-Plus Door Controls

Features

Doors controlled
Users
User Groups
Time Zones
Door Groups
Reporting Facility
Challenge Facility
Logging
Input/Output Mapping
Supports Wireless & RS485 Networks
Automatic Backup Facility
Database Encryption

10

5000

16
16
16

Yes
Yes

Unlimited

CCTV & Lift control

Yes
Yes
Yes

Installation Steps

Step    Description

       Page

   1        Install the Controller using the Installation Diagrams

        4-5

   2        System Overview                                                                                  6-7

   3        Wire the Controller using the Wiring Diagrams

         8

   4        Install and wire each Door Control. Refer to the Door Control

             Manual for instructions.

   5        Connect the Controller to the PC using Network Diagrams

       9-11

   6        Restoring Factory Defaults

        11

   7        Phase 1- Setting up the GSD Controller via the PC application         12

   8        Phase 2 - Configuring the GSD Controller via the PC application      13

   9        Phase 3 - Defaulting Door Controls                                                    14

  10       Phase 4 - Enrolling Door Controls 

      15-16

  11       Phase 5 - Configuring Users 

        17

  12       Phase 6 - Configuring Access Levels              

        18

  13       Phase 7 - Downloading Configuration

        18

  14       Enrolling User Fingerprints

        19

  15       Correct Finger Placement techniques                                             20-23

Installation Steps

Содержание Wi-Plus Controller

Страница 1: ...website www globalsecurity ie 4 Installation Instructions 12 Network Diagrams Wiring Diagrams 19 Fingerprint Enrollment Operating Instructions YOUR SECURITY IS OUR PRIORITY Installation Manual V2 08...

Страница 2: ...s Wireless RS485 Networks Automatic Backup Facility Database Encryption 10 5000 16 16 16 Yes Yes Unlimited CCTV Lift control Yes Yes Yes Installation Steps Step Description Page 1 Install the Controll...

Страница 3: ...ng the rear enclosure to the wall To remove front cover lift tab up and unhook door To re attach front cover hook door over top pip and rotate into position and push tab down to secure 4 Installation...

Страница 4: ...rk to Controllers Max number of Controllers 3 Max Cable Length 1 4 km Controller 1 Controller 2 3 Door Control 4 7 System Overview Note If using a single Controller an RS232 cable may be used Max cabl...

Страница 5: ...ors will be opened 8 Wiring Diagrams IP4 IP3 0V IP2 IP1 V 0V VOUT OP3 OP4 A B COM 1 2 3 4 OFF ON IP4 IP3 0V IP2 IP1 Inputs TCP_IP 3V Lithium V 0V Power In 12V Outputs OP1 RLY 1 0V 9 Network Diagrams f...

Страница 6: ...Address 2 Set SW2 ON Note Address 3 Set SW3 ON only The Controller Address is set by configuring the Dip switches as shown below Configuring GSD Controller Communications OFF ON 1 2 3 4 IP4 IP3 0V IP2...

Страница 7: ...d choosing the com port that the serial cable is connected to from the drop down list in the communications section E The Controller icon will change colour from gray off line to green on line to show...

Страница 8: ...e 4 Enrolling Door Controls Note For Wired 485 Door Controls right click on the Controller on the right hand side of the application and select Manually Assign Address from the drop down menu Once all...

Страница 9: ...ill be denied for all cards and PINs on that Door Control Example To Enable PIN codes only on a Wi PIN Prox Set the Timed Action Card or PIN to Inactive and set the Timed Action PIN Only to All day Ev...

Страница 10: ...nd drag it to the Doors in Current Group to add it to the Door Group Repeat for adding doors as desired Step Description After all users access levels and door control settings have been finalised a f...

Страница 11: ...inger Placement 20 Finger Placement Wi BIO Note Good Quality image Fingerprint core is center of sensor window Note Ensure that the core of finger is centered on the sensor window during the enrollmen...

Страница 12: ...Correct Finger Placement 22 Finger Placement Wi BIO Incorrect Finger Placement 23 Finger Placement Wi BIO...

Отзывы: