- 4 -
SID 162
2.2 m
eaning
of
the
symbols
used
Important note
•
Performing works
2.3 t
eChniCal
data
The requirements of the following are met:
2011/65/EU, 2014/30/EU, 2014/35/EU
The product fulfils the guidelines and standards for CE labelling (page 10).
Unless otherwise noted all values are specified as “typical”.
Frequency range: ....................................................... 950 … 2150 MHz
SAT IF inputs: ......................................................................... 2 F sockets
SAT IF loop-through output: ....................................................... 1 F socket
SAT IF outputs: .................................................................. 6 + 4 F sockets
Input / output impedance: .............................................................. 75
Ω
Decoupling of the outputs: ..............................................................20 dB
Loss 1-6 fold (see page 5): .......................................................9 … 14 dB
Loop-through loss: ............................................................................8 dB
Loss 1-4 fold (see page 5) ........................................................9 … 12 dB
LNB operating voltage supply (via external connector): ....... max. 800 mA
2.4 d
esCription
The SAT IF distributor SID 162 is equipped with two SAT IF inputs, one loop-
through output and 10 SAT IF outputs. This enables to distribute two reception
areas to 4 and 6 SAT IF outputs. Using the loop-through output the reception
area 1 can be distributed to the 10 outputs. The F sockets of both reception
areas are marked with different colours.