3. Technical Data
3.1 General Data
3.1.1 Dosing flow
3.2 Data of the accessory components
3.2.1 Servomotor with reversing potentiometer
Fig. 13
Servomotor with reversing potentiometer
Permissible medium
Cl
2
Deviation of linearity
± 4 % of upper limit
Deviation of reproducibillity
± 2 % of upper limit
Control range
1:20
Connections VGS-141 (up to 10 kg/h)
DN 10, for PVC-pipe DN 10 or PE-tube 10/14
Connections VGS-143 (up to 40 kg/h)
DN 20, for PVC-pipe DN 20
Connections VGS-145 (up to 200 kg/h)
DN 40, for PVC-pipe DN 40
Materials
Polyurethan (enclosure), PVC, FEP, PTFE, FKM, Copper-nickel alloy and a special alloy
Type
Dosing flow
VGS-141
10-200 g/h
0.5 - 10.5 #/day
25-500 g/h
2-26 #/day
50-1000 g/h
3-52 #/day
100-2000 g/h
5-100 #/day
200-4000 g/h
10-200 #/day
400-8000 g/h
20-420 #/day
500-10000 g/h
30-520 #/day
VGS-143
1-20 kg/h
50-1050 #/day
2-40 kg/h
100-2100 #/day
VGS-145
3.5 - 70 kg/h
200-3700 #/day
6-120 kg/h
400-6200 #/day
10-200 kg/h
500-10500 #/day
T
M
04
09
56
40
0
9
Item
Description
1
SR, limit switch cam min.
SL, limit switch cam max.
2
Mains voltage input
3
Potentiometer input/output
4
Earth terminal
2
1,
3
4
SL
SR
1,
Mains voltage
220-240 V ± 10 %, 50/60 Hz ± 5 %,
100 % on time (standard)
110-120 V ± 10 %, 50/60 Hz ± 5 %
24 V AC ± 10 %, 50/60 Hz ± 5 %
Rated current
30 mA (at 230 V),
60 mA (at 115 V),
240 mA (at 24 V)
Limit switch - load
capacity
2 A at 250 V
Power consumption
Approx. 2 VA
Control variant
Reversingpotentiometer 1 k
Open/close signal
Actuating time
90 s for 270 ° at 50 Hz
75 s for 270 ° at 60 Hz
Adjustment angle
Max. 270 °
Degree of protection
IP65
Permissible ambient
temperature
-15 °C to 60 °C
Weight
2.6 kg