background image

6

English (US)

5. Starting up the product

5.1 Setting the optional timer

Fig. 3

Timer

5.1.1 Setting the time, date, DST (Daylight 

Savings Time), and region

Fig. 4

Zone selections

DANGER

Electric shock
Death or serious personal injury
- Do not plug this timer into an 

extension cord.

- Always plug the 3-prong plug 

directly into a properly grounded 
outlet. Never attempt to defeat this 
safety feature.

- Do not use the timer to control 

devices that could have dangerous 
consequences due to inaccurate 
timing, such as sun lamps, sauna, 
heaters, and crock pots.

- Follow all local electrical codes 

during use.

There are no user serviceable parts 
inside.

Before initial use, plug the timer into 
an AC outlet for at least 30 minutes to 
charge the internal battery. If the 
display is not visible, press [RESET] 
to restart the timer and erase all 
settings and events. You may unplug 
the timer from the AC outlet for easier 
setting.

TM

07 16

82 201

8

When setting the timer, if you pause 
for more than 30 seconds, the timer 
will automatically return to normal time 
of day display.

1. Press [TIME]. A flashing 

4-digit year appears.

2. Press [+] or [-] to set the 

current year and then 
press [TIME].

3. Press [+] or [-] to set the 

month ("01"=Jan, 
"12"=Dec) and then 
press [TIME].

4. Press [+] or [-] to set the 

day of the month.

5. Press [TIME] to set 

"DST" (Daylight Saving 
Time) function.

6. Press [+] or [-] to select 

"AUTO" (AUTO DST 
adjust enabled) or "OFF" 
(DST disabled).
NOTE: DST enables the 
timer to automatically 
move ahead 1 hour on 
the second Sunday in 
March at 02:00 AM and 
then automatically adjust 
back 1 hour on the first 
Sunday in November at 
02:00 AM.

7. Press [TIME]. The hour 

digit flashes.

8. Press [+] or [-] to set the 

current hour, then press 
[TIME]. The minute digit 
flashes.

9. Press [+] or [-] to set the 

minute, then press 
[TIME].

10. Press [+] or [-] to set 

your current zone. The 
map below will determine 
what zone the timer is 
being used in. Once the 
zone is selected, the 
timer will automatically 
set the sunrise and 
sunset time.

TM

07

 16

83

 20

18

T

M

07

 16

84

 20

18

 

 

 

 

 

 

 

1. North

2. Central

3. South

Содержание UP 15 series

Страница 1: ...GRUNDFOS INSTRUCTIONS UP S 15 circulators With power cable and optional digital timer Installation and operating instructions ANSI NSF372...

Страница 2: ...be returned to the distributor or dealer of Grundfos products from which it was purchased together with proof of purchase and installation date failure date and supporting installation data Unless oth...

Страница 3: ...Ensure that the voltage and frequency of the product match the voltage and frequency of the installation site See section 7 1 Nameplate for information on the nameplate Examine the product to make sur...

Страница 4: ...ress on the pump Fig 1 Acceptable pump mounting positions WARNING Electric shock Death or serious personal injury Switch off the power supply before starting any work on the product Make sure that the...

Страница 5: ...is unplugged Close the isolating valves before removing the hex socket head screws on the pump 1 While supporting the stator motor use a 4 mm or 5 mm wrench to remove the four 4 hex socket head screw...

Страница 6: ...easier setting TM07 1682 2018 When setting the timer if you pause for more than 30 seconds the timer will automatically return to normal time of day display 1 Press TIME A flashing 4 digit year appear...

Страница 7: ...n at sunrise or sunset proceed to step 7 7 Press or to scroll to one of the 2 screens with moon and sun icons flashing and AM or PM flashing The AM plus icons screen means this event will happen at su...

Страница 8: ...undfos UP S 15 pump is designed for domestic hot water recirculation Grundfos UP S Series 15 pumps are designed for indoor use only Grundfos UP S 15 series pumps with stainless steel or bronze volutes...

Страница 9: ...of the pump 3 Remove the large screw in the middle of the nameplate 4 Insert a small flat blade screwdriver into the end of the shaft and gently turn it until the shaft moves freely See fig 2 5 Repla...

Страница 10: ...is table In a pressurized system the required inlet pressure is the minimum allowable system pressure In an open system the required inlet pressure is the minimum distance at which the pump must be lo...

Страница 11: ...3500 www grundfos us GRUNDFOS Canada 2941 Brighton Road Oakville Ontario L6H 6C9 Canada Phone 1 905 829 9533 Telefax 1 905 829 9512 www grundfos ca GRUNDFOS M xico Boulevard TLC No 15 Parque Industri...

Страница 12: ...1229 www grundfos com The name Grundfos the Grundfos logo and be think innovate are registered trademarks owned by Grundfos Holding A S or Grundfos A S Denmark All rights reserved worldwide Copyright...

Отзывы: