background image

En
gl

is

h (
G

B)

14

3. If connected correctly, the pump will jerk in the 

opposite direction of the direction of rotation. 
See fig. 10.

4. If the direction of rotation is wrong, interchange 

two phases. See fig. 4 or 5.

Fig. 10

Jerk direction

10. Maintenance and service

Flush the pump thoroughly with clean water before 
maintenance and service. Rinse the pump parts in 
water after dismantling. 

10.1 Yearly maintenance

Pumps running normal operation should be checked 
every 3000 operating hours or at least once a year. 
If he dry solids content of the pumped liquid is very 
high or sandy, check the pump at shorter intervals. 
Check the following points: 

Power consumption

 

See section 

4.1 Nameplate

.

Motor oil level and oil condition

When the pump is new or after replacement of 
the shaft seal, check the oil level after one week 
of operation.
Use Shell Ondina X420 oil or similar type. 
See sections 

10.2 Change of motor oil

.

Cable entry

Make sure that the cable entry is watertight and 
that the cables are not sharply bent and/or 
pinched. See section 

10.5 Service kits

.

Pump parts

Check the impeller, pump housing, etc. for 
possible wear. Replace defective parts. 
See section 

10.5 Service kits

.

Ball bearings

Check the shaft for noisy or heavy operation (turn 
the shaft by hand). Replace defective ball 
bearings.
A general overhaul of the pump is usually 
required in case of defective ball bearings or poor 
motor function. This work must be carried out by 
Grundfos or a service workshop authorised by 
Grundfos.

Grinder system/parts

In case of frequent choke-ups, check the grinder 
system for wear. When worn, the edges of the 
grinding parts are round and worn. Compare with 
a new grinder system. 

TM

02

 53

93

 28

02

Warning

Before starting work on the pump, 
make sure that the fuses have been 
removed or the mains switch has been 
switched off. Make sure that the power 
supply cannot be accidentally switched 
on.

All rotating parts must have stopped 
moving.

Warning

Except for service on the pump parts, 
all other service work must be carried 
out by Grundfos or a service workshop 
authorised by Grundfos.

Warning

When loosening the screws of the oil 
chamber, note that pressure may have 
built up in the chamber. Do not remove 
the screws until the pressure has been 
fully relieved.

Note

Used oil must be disposed of in 
accordance with local regulations. 

Note

A possible replacement of the cable 
must be carried out by Grundfos or a 
service workshop authorised by 
Grundfos.

Содержание SEG.40.09

Страница 1: ...SEG 60 Hz Installation and operating instructions GRUNDFOS INSTRUCTIONS...

Страница 2: ...he shaft seal 15 10 4 Adjustment of impeller clearance 15 10 5 Service kits 17 10 6 Contaminated pumps 17 11 Fault finding 18 12 Technical data 19 13 Disposal 19 Warning Prior to installation read the...

Страница 3: ...n auto coupling system or stand freely on the bottom of the tank 2 3 Operating conditions The Grundfos SEG range are designed for intermittent operation S3 When completely submerged the pumps can also...

Страница 4: ...g periods of storage the pump must be protected against moisture and heat After a long period of storage the pump should be inspected before it is put into operation Make sure that the impeller can ro...

Страница 5: ...atab nya Hungary 1 2 15 16 17 18 19 20 21 22 23 24 25 26 27 28 3 4 5 6 7 9 10 11 12 13 14 8 US C Pos Description Pos Description 1 FM description 14 Electrical safety 2 Type designation 15 Approval 3...

Страница 6: ...pump inlet Material Standard cast iron Max spherical impeller clearance mm Not relevant for SEG pumps 40 50 K40 K50 Pump discharge Nominal diameter of discharge port mm DIN PN 10 flange Nominal diamet...

Страница 7: ...ns with reduced physical sensory or mental capabilities must not use this product unless they are under supervision or have been instructed in the use of the product by a person responsible for their...

Страница 8: ...ide rails and finally fasten it firmly to the tank wall 6 Clean out debris from the tank before lowering the pump into the tank 7 Fit the guide claw to the discharge port of the pump 8 Slide the guide...

Страница 9: ...must be mounted on separate feet accessory In order to facilitate service on the pump fit a flexible union or coupling to the discharge pipe for easy separation If a hose is used make sure that the ho...

Страница 10: ...h which ensures all pole disconnection with a contact separation according to EN 60204 1 5 3 2 It must be possible to lock the mains switch in position 0 Type and requirements as specified in EN 60204...

Страница 11: ...d LCD 110 with electrodes In the following description level switches can be air bells float switches or electrodes depending on the pump controller selected Controllers for single phase pumps incorpo...

Страница 12: ...and check whether the impeller can rotate freely Turn the grinder head by hand 2 Check the condition of the oil in the oil chamber See also section 10 2 Change of motor oil 3 Check whether the monitor...

Страница 13: ...tation is clockwise when viewed from above When started the pump will jerk in the opposite direction of the direction of rotation If the direction of rotation is wrong interchange two phases See fig 4...

Страница 14: ...Replace defective parts See section 10 5 Service kits Ball bearings Check the shaft for noisy or heavy operation turn the shaft by hand Replace defective ball bearings A general overhaul of the pump i...

Страница 15: ...th oil screws using the packing material included in the kit See section 10 5 Service kits 10 3 Checking the shaft seal To make sure that the shaft seal is intact the oil should be checked If the oil...

Страница 16: ...tate any more 10 Slacken the adjusting nut 68 by 1 4 turn Assembly of grinder system 1 Fit grinder head 45 The dogs on the back of the grinder head must engage with the impeller holes 49 2 Tighten scr...

Страница 17: ...hed off Make sure that the power supply cannot be accidentally switched on All rotating parts must have stopped moving Service kit Description Pump type Material Product number Shaft seal kit Shaft se...

Страница 18: ...consumption due to large voltage drop Measure the voltage between two motor phases Tolerance 10 6 c Impeller blocked by impurities Increased current consumption in all three phases Clean the impeller...

Страница 19: ...s com The curves are to be considered as a guide They must not be used as guarantee curves Test curves for the supplied pump are available on request Sound pressure level The sound pressure level of t...

Страница 20: ...Appendix 20 Appendix 1 Dimensional drawings Fig 1 One pump installation on auto coupling TM02 5388 1310...

Отзывы: