8. Electrical connection

The supply voltage and frequency are marked on the 
pump nameplate. The permissible voltage tolerance 
is - 10 %/+ 6 % of the rated voltage. Make sure that 
the motor is suitable for the power supply available 
at the installation site.
All pumps are supplied with 10 metres of cable and a 
free cable end.
All pumps are supplied without a control box.
The pump must be connected to one of these two 
controller types:

a control box with motor-protective circuit 
breaker, such as a Grundfos CU 100 control box

a Grundfos LC, LCD 107, LC, LCD 108 or LC, 
LCD 110 pump controller.

See fig. 4 or 5 and the installation and operating 
instructions for the selected control box or pump 
controller.
For more information about the function of the 
thermal switches, see section 

8.4 Thermal switches

.

8.1 Wiring diagrams

Fig. 4

Wiring diagram for single-phase pumps

Fig. 5

Wiring diagram for three-phase pumps

Warning

Connect the pump to an external mains 
switch which ensures all-pole 
disconnection with a contact 
separation according to EN 60204-1,  
5.3.2.

It must be possible to lock the mains 
switch in position 0. 

Type and requirements as specified in 
EN 60204-1, 5.3.2.

The electrical connection must be 
carried out in accordance with local 
regulations.

Warning

The pumps must be connected to a 
control box with a motor protection 
relay with an IEC trip class 10 or 15.

Warning

The permanent installation must be 
fitted with earth leakage circuit breaker 
(ELCB) with a tripping current < 30 mA.

Warning

Pumps installed in hazardous locations 
must be connected to a control box 
with a motor protection relay with an 
IEC trip class 10.

Warning

The cross-section of the earth lead 
must be at least 4 mm

2

, e.g. type H07 

V2-K (PVT 90 °) yellow/green.

Make sure that the earth connection is 
protected from corrosion.

Make sure that all protective equipment 
has been connected correctly.

Note

Set the motor-protective circuit breaker 
to the rated current of the pump. 
The rated current is stated on the pump 
nameplate.

TM0

2

 558

4

3

0

2

TM

02

 55

88

 36

02

150

˚

C

160

˚

C

PE

1

2

3

6

4

5

1

T3

T2

T1

L

N

PE

150

˚

C

170

˚

C

PE

1

2

3

6

4

5

3

T3

T2

T1

L1

PE

L2 L3

Содержание SEG.40.09

Страница 1: ...SEG 60 Hz Installation and operating instructions GRUNDFOS INSTRUCTIONS...

Страница 2: ...he shaft seal 15 10 4 Adjustment of impeller clearance 15 10 5 Service kits 17 10 6 Contaminated pumps 17 11 Fault finding 18 12 Technical data 19 13 Disposal 19 Warning Prior to installation read the...

Страница 3: ...n auto coupling system or stand freely on the bottom of the tank 2 3 Operating conditions The Grundfos SEG range are designed for intermittent operation S3 When completely submerged the pumps can also...

Страница 4: ...g periods of storage the pump must be protected against moisture and heat After a long period of storage the pump should be inspected before it is put into operation Make sure that the impeller can ro...

Страница 5: ...atab nya Hungary 1 2 15 16 17 18 19 20 21 22 23 24 25 26 27 28 3 4 5 6 7 9 10 11 12 13 14 8 US C Pos Description Pos Description 1 FM description 14 Electrical safety 2 Type designation 15 Approval 3...

Страница 6: ...pump inlet Material Standard cast iron Max spherical impeller clearance mm Not relevant for SEG pumps 40 50 K40 K50 Pump discharge Nominal diameter of discharge port mm DIN PN 10 flange Nominal diamet...

Страница 7: ...ns with reduced physical sensory or mental capabilities must not use this product unless they are under supervision or have been instructed in the use of the product by a person responsible for their...

Страница 8: ...ide rails and finally fasten it firmly to the tank wall 6 Clean out debris from the tank before lowering the pump into the tank 7 Fit the guide claw to the discharge port of the pump 8 Slide the guide...

Страница 9: ...must be mounted on separate feet accessory In order to facilitate service on the pump fit a flexible union or coupling to the discharge pipe for easy separation If a hose is used make sure that the ho...

Страница 10: ...h which ensures all pole disconnection with a contact separation according to EN 60204 1 5 3 2 It must be possible to lock the mains switch in position 0 Type and requirements as specified in EN 60204...

Страница 11: ...d LCD 110 with electrodes In the following description level switches can be air bells float switches or electrodes depending on the pump controller selected Controllers for single phase pumps incorpo...

Страница 12: ...and check whether the impeller can rotate freely Turn the grinder head by hand 2 Check the condition of the oil in the oil chamber See also section 10 2 Change of motor oil 3 Check whether the monitor...

Страница 13: ...tation is clockwise when viewed from above When started the pump will jerk in the opposite direction of the direction of rotation If the direction of rotation is wrong interchange two phases See fig 4...

Страница 14: ...Replace defective parts See section 10 5 Service kits Ball bearings Check the shaft for noisy or heavy operation turn the shaft by hand Replace defective ball bearings A general overhaul of the pump i...

Страница 15: ...th oil screws using the packing material included in the kit See section 10 5 Service kits 10 3 Checking the shaft seal To make sure that the shaft seal is intact the oil should be checked If the oil...

Страница 16: ...tate any more 10 Slacken the adjusting nut 68 by 1 4 turn Assembly of grinder system 1 Fit grinder head 45 The dogs on the back of the grinder head must engage with the impeller holes 49 2 Tighten scr...

Страница 17: ...hed off Make sure that the power supply cannot be accidentally switched on All rotating parts must have stopped moving Service kit Description Pump type Material Product number Shaft seal kit Shaft se...

Страница 18: ...consumption due to large voltage drop Measure the voltage between two motor phases Tolerance 10 6 c Impeller blocked by impurities Increased current consumption in all three phases Clean the impeller...

Страница 19: ...s com The curves are to be considered as a guide They must not be used as guarantee curves Test curves for the supplied pump are available on request Sound pressure level The sound pressure level of t...

Страница 20: ...Appendix 20 Appendix 1 Dimensional drawings Fig 1 One pump installation on auto coupling TM02 5388 1310...

Отзывы: