WARNING
Pressurised system
Death or serious person-
al injury
‐
The oil chamber may
be under pressure.
Loosen the screws
carefully and do not
remove them until
the pressure has
been fully relieved.
Dispose of used oil in
accordance with local
regulations.
Repairing the product
DANGER
Electric shock
Death or serious person-
al injury
‐
Before starting any
work on the product,
make sure that the
fuses have been re-
moved or the main
switch has been
switched off and
locked in position 0.
Make sure that the
power supply cannot
be switched on unin-
tentionally.
WARNING
Crushing hazard
Death or serious person-
al injury
‐
Do not stand near or
under the pump
when it is lifted.
Inspect the oil level and
condition every 3000 op-
erating hours or at least
once a year.
When the pump is new
or after the replacement
of the shaft seal, check
the oil level and water
content after one week
of operation.
Replacing the impeller
CAUTION
Sharp element
Minor or moderate per-
sonal injury
‐
Do not touch the
sharp edges of the
impeller without
wearing protective
gloves.
30