5. Fault finding chart

6. Disposal

This product or parts of it must be disposed of in 
an environmentally sound way:

1.

Use the public or private waste collection 
service.

2.

If this is not possible, contact the nearest 
Grundfos company or service workshop.

Before any dismantling, make sure that the electricity supply has been switched off and 
that it cannot be accidentally switched on.

Fault

Cause

1. The temperature indication on the PR 5714 relay 

does not drop even if the motor has been stopped 
for more than 5 minutes.

a) The Pt100 sensor is defective.

Check the sensor cable. 
The resistance values below apply to a standard 
sensor cable: 
White lead to white lead: 0-10 

Ω

 – OK.

Red lead to red lead: 0-10 

Ω

 – OK.

White lead to red lead: 100-150 

Ω

 – OK.

b) The PR 5714 relay is defective.

2. The PR 5714 relay does not indicate a 

temperature within the range of 0-100°C.

a) The Pt100 sensor is defective.
b) The PR 5714 relay is defective.

Subject to alterations.

Содержание Pt100

Страница 1: ...Pt100 GRUNDFOS INSTRUCTIONS Installation and operating instructions...

Страница 2: ...2...

Страница 3: ...tructions 4 Montage und Betriebsanleitung 8 Notice d installation et d entretien 13 Instrucciones de instalaci n y funcionamiento 17 Monterings og driftsinstruktion 21 Instrukcja monta u i eksploatacj...

Страница 4: ...n page 39 1 Separate the motor from the pump 2 Check the motor liquid level 3 Remove one of the staybolts close to the plug pos A Reuse the nut pos B 4 Fit the special staybolt pos C with the through...

Страница 5: ...ing hole is the highest point of the motor 8 Inject motor liquid into the motor 9 Fit the motor to the pump 10 Check whether the sensor cable and the motor cable can be placed in the cable guard If no...

Страница 6: ...cted to an external alarm device for alarm indication in case the stop or warning limits are exceeded 4 1 1 Operating functions of the PR 5714 relay During operation the motor temperature is indicated...

Страница 7: ...ally switched on Fault Cause 1 The temperature indication on the PR 5714 relay does not drop even if the motor has been stopped for more than 5 minutes a The Pt100 sensor is defective Check the sensor...

Страница 8: ...39 Fig A MS 6000 model A Fig B MS 6000 model B TM03 5452 3606 B D 1 2 5 7 1 4 A C TM03 5453 3606 B D 1 2 5 7 1 4 A C...

Страница 9: ...40 Fig C MMS 6000 and MMS 8000 TM03 5454 3606 B B 250 mm A 1 2 5 7 1 4...

Страница 10: ...41 Fig D MMS 10000 Fig E MMS 12000 TM03 5450 3606 B A 1 2 5 7 1 4 TM03 5450 3606 TM03 5451 3606 B A 1 2 5 7 1 4...

Страница 11: ...141 0022 Japan Phone 81 35 448 1391 Telefax 81 35 448 9619 Korea GRUNDFOS Pumps Korea Ltd 6th Floor Aju Building 679 5 Yeoksam dong Kangnam ku 135 916 Seoul Korea Phone 82 2 5317 600 Telefax 82 2 5633...

Страница 12: ...www grundfos com Being responsible is our foundation Thinking ahead makes it possible Innovation is the essence 96409388 0309 308 Repl 96409388 0908...

Отзывы: