1. General 

1.1 Applications 

The Pt100 is a temperature-dependent resistance 
sensor, suitable for fitting in a submersible motor. 

A Pt100 sensor allows

• continuous monitoring of the motor temperature 

and 

• protection against too high motor temperature.

The Pt100 sensor is used for temperature monitoring 
of 

• Grundfos MS 6000 motors

• Grundfos MMS 6000, 8000, 10000 and 12000 

motors.

Note:

 When fitted in an MS 6000 motor with 

defective temperature transmitter (Tempcon) and 
connected to a control unit, the Pt100 makes it 
possible to re-establish monitoring and protection of 
the motor.

1.2 Frequency converter

The Pt100 sensor allows monitoring of the 
temperature in MS 6000 motors connected to 
a frequency converter.

2. Technical data

The Pt100 sensor is supplied with an PR 5714 relay.

The technical specifications for the PR 5714 relay 
can be found in the installation and operating 
instructions supplied with the relay.

3. Installation 

3.1 MS 6000 motors with Pt100 sensor

The Pt100 sensor is placed in the special staybolt 
supplied with the Pt100 kit. The sensor will thus 
acquire approximately the same temperature as 
the motor liquid during operation.

3.1.1 MS 6000, model A

To fit the Pt100 sensor, proceed as follows:

See fig. A on page 39.

1.

Separate the motor from the pump.

2.

Check the motor liquid level.

3.

Remove one of the staybolts close to the plug, 
pos. A. Reuse the nut, pos. B.

4.

Fit the special staybolt, pos. C, with the through-
going hole pointing outwards and tighten it to 
50 Nm.

5.

Fit the motor to the pump. Tighten the bolts 
diagonally to 50 Nm.

6.

Place the sensor with the shrink-on sleeve, 
pos. D, in the hollow staybolt, pos. C.

7.

Heat the sleeve so that there is a connection 
between the staybolt thread and the sensor 
cable. 

8.

Note:

 Instead of the shrink-on sleeve, it is 

possible to use resin (part No. ID1302) with 
a hardening time of 12 hours.

9.

Check whether the sensor cable and the motor 
cable can be placed in the cable guard.
If not, fit the sensor cable on the side of the 
cable guard so that the cable is protected 
against damage when the pump is lowered into 
the borehole.

10. Fit the cable guard.

11. Fasten the sensor cable to the motor cable with 

cable clips.

3.1.2 MS 6000, model B

To fit the Pt100 sensor, proceed as follows: 

See fig. B on page 39.

1.

Slacken the four hexagon-head screws in the 
motor top.

2.

Check the motor liquid level.

3.

Remove one of the hexagon-head screws close 
to the plug, pos. A.

4.

Fit the special staybolt in the motor top, pos. C.

5.

Fit the motor to the pump. Tighten the screws 
diagonally to 50 Nm.

6.

Pull the union nut, pos. B, and the rubber 
gasket, pos. D, up behind the sensor and then 
press the sensor to the bottom of the bolt, 
pos. C.

7.

Tighten the union nut so that the sensor cable 
is secured by the rubber gasket. 

8.

Check whether the sensor cable and the motor 
cable can be placed in the cable guard.
If not, fit the sensor cable on the side of the 
cable guard so that the cable is protected 
against damage when the pump is lowered into 
the borehole.

Prior to installation, read these installation 
and operating instructions. Installation and 
operation must comply with local 
regulations and accepted codes of good 
practice.

Содержание Pt100

Страница 1: ...Pt100 GRUNDFOS INSTRUCTIONS Installation and operating instructions...

Страница 2: ...2...

Страница 3: ...tructions 4 Montage und Betriebsanleitung 8 Notice d installation et d entretien 13 Instrucciones de instalaci n y funcionamiento 17 Monterings og driftsinstruktion 21 Instrukcja monta u i eksploatacj...

Страница 4: ...n page 39 1 Separate the motor from the pump 2 Check the motor liquid level 3 Remove one of the staybolts close to the plug pos A Reuse the nut pos B 4 Fit the special staybolt pos C with the through...

Страница 5: ...ing hole is the highest point of the motor 8 Inject motor liquid into the motor 9 Fit the motor to the pump 10 Check whether the sensor cable and the motor cable can be placed in the cable guard If no...

Страница 6: ...cted to an external alarm device for alarm indication in case the stop or warning limits are exceeded 4 1 1 Operating functions of the PR 5714 relay During operation the motor temperature is indicated...

Страница 7: ...ally switched on Fault Cause 1 The temperature indication on the PR 5714 relay does not drop even if the motor has been stopped for more than 5 minutes a The Pt100 sensor is defective Check the sensor...

Страница 8: ...39 Fig A MS 6000 model A Fig B MS 6000 model B TM03 5452 3606 B D 1 2 5 7 1 4 A C TM03 5453 3606 B D 1 2 5 7 1 4 A C...

Страница 9: ...40 Fig C MMS 6000 and MMS 8000 TM03 5454 3606 B B 250 mm A 1 2 5 7 1 4...

Страница 10: ...41 Fig D MMS 10000 Fig E MMS 12000 TM03 5450 3606 B A 1 2 5 7 1 4 TM03 5450 3606 TM03 5451 3606 B A 1 2 5 7 1 4...

Страница 11: ...141 0022 Japan Phone 81 35 448 1391 Telefax 81 35 448 9619 Korea GRUNDFOS Pumps Korea Ltd 6th Floor Aju Building 679 5 Yeoksam dong Kangnam ku 135 916 Seoul Korea Phone 82 2 5317 600 Telefax 82 2 5633...

Страница 12: ...www grundfos com Being responsible is our foundation Thinking ahead makes it possible Innovation is the essence 96409388 0309 308 Repl 96409388 0908...

Отзывы: