10. List of alarms
11. Technical data
*)
The start pressure (p
start
) depends on the variant. See the nameplate.
The technical data may be limited by the pump data. See installation and operating instructions for the pump.
Indication
Alarm
Cause
"Alarm" is permanently on.
Dry running.
The pump has been running without water.
"Alarm" is flashing.
Cycling.
The pump is cycling.
Note:
Occurs only if the anti-cycling function is
enabled. See section
Data
230 V model
115 V model
Supply voltage
1 x 220-240 VAC
1 x 110-120 VAC
Maximum inductive contact load
10 A
14 A
Frequency
50/60 Hz
Maximum ambient temperature
See nameplate.
Liquid temperature
0 °C - see nameplate.
p
start
*)
PM 1 - 15
1.5 bar
PM 1 - 22
2.2 bar
Q
min.
1.0 litre/min.
Time delay during stopping
10 seconds
Maximum operating pressure
PN 10 / 10 bar / 1 MPa
Enclosure class
IP65
Dimensions
See fig.
, page