English (GB)
3
1.1.2 Other important notes
2. Installing the product
2.1 Location
The pump can be installed in a well or pond for
permanent or portable use in vertical position.
Fig. 1
Location of KPC pump
2.1.1 Minimum space for the float switch
The pumps require 5 cm free space between the
float switch and the wall. The free space ensures
free movability of the float switch.
KPC 300 A
Fig. 2
Minimum pit dimensions for KPC 300 A
KPC 600 A
Fig. 3
Minimum pit dimensions for KPC 600 A
A blue or grey circle with a white graphical
symbol indicates that an action must be
taken.
If these instructions are not observed, it
may result in malfunction or damage to the
equipment.
Tips and advice that make the work easier.
Observe local regulations setting limits for
manual lifting or handling.
CAUTION
Crushing of feet
Minor or moderate personal injury
- Use safety shoes when handling the
pump.
Make sure that there are minimum 3 m
free cable above the liquid level. This limits
the maximum installation depth to 7 m for
pumps with a 10 m cable and to 2 m for
pumps with a 5 m cable.
T
M
06
80
29
47
16
Max. 40 °C / Min. 0 °C
Max. 7 m
Max. 3 m
< KPC 300A: 10 mm
< KPC 600A: 10 mm
On
Min. 5 cm
T
M
02
91
00
05
1
3
TM
02
91
01
05
13