background image

TM058227

Fig.

Correct pipe sizing for connection to the pump inlet or
outlet

3.2.4 Installation examples

We recommend that you follow the installation examples.
Valves are not supplied with the pump.

3.2.4.1 Suction from a tank

This installation example shows JP PM, but it applies to all variants
of the JP range.
  

1

2

4

3

3

6

5

7

TM072435

Pos. Description

1

Highest tapping point.

2

Isolating valve.

3

Pipe support.

4

Pressure manager.

5

Drain to sewer.

6

Strainer. A foot valve is optional. We recommend using a
foot valve together with JP PM.

7

5 ° angle.

3.2.4.2 Suction from a well

This installation example shows the JP PM, but it applies to all
variants of the JP range.
  

6

1

7

2

4

3

3

5

TM072434

Pos. Description

1

Highest tapping point.

2

Isolating valve.

3

Pipe support.

4

Pressure manager.

5

5 ° angle.

6

Foot valve with strainer. The foot valve is optional. We
recommend using a foot valve together with JP PM.

7

Pump cover.

3.3 Electrical connection

WARNING
Electric shock

Death or serious personal injury

Switch off the power supply before you start any work
on the product. Make sure that the power supply
cannot be switched on accidentally.

WARNING
Electric shock

Death or serious personal injury

The product is supplied with a grounding conductor
and grounding-type attachment plug. To reduce the
risk of electric shock, be certain that the product is
connected only to a properly grounded, grounding-type
receptacle (protective earth).

WARNING
Electric shock

Death or serious personal injury

If national legislation requires a residual-current device
(RCD) or equivalent in the electrical installation, this
must be type A or better.

WARNING
Electric shock

Death or serious personal injury

If the product is used for cleaning or maintenance of
swimming pools, garden ponds or similar places, make
sure that the product is supplied through a residual-
current device (RCD) with a rated residual operating
current not exceeding 30 mA.

All electrical connections must be carried out by qualified
persons in accordance with local regulations.

8

English (GB)

Содержание JP 3-42

Страница 1: ...JP and JP Booster Installation and operating instructions GRUNDFOS INSTRUCTIONS...

Страница 2: ...his document before you install the product Installation and operation must comply with local regulations and accepted codes of good practice 1 1 Target group These installation and operating instruct...

Страница 3: ...40 55 C 50 Hz 60 Hz JP 3 42 ON 20 min OFF 40 min ON 20 min OFF 40 min JP 4 47 ON 15 min OFF 45 min ON 10 min OFF 50 min JP 4 54 ON 20 min OFF 40 min ON 20 min OFF 40 min JP 5 48 ON 20 min OFF 40 min...

Страница 4: ...esigned for the maximum pump pressure The maximum inlet pressure depends on the head at the actual duty point The sum of the inlet pressure and the head must not exceed the maximum system pressure We...

Страница 5: ...Electrical connection WARNING Electric shock Death or serious personal injury Switch off the power supply before you start any work on the product Make sure that the power supply cannot be switched on...

Страница 6: ...correct terminal in the external main switch Wiring a plug 1 Strip the cable 2 Loosen the two screws holding the cable clamp and pull the cable through 3 Thread each individual wire to the correct ter...

Страница 7: ...ependent motor protection If the pump is running without water is blocked or otherwise overloaded the built in thermal switch will cut out When the motor has cooled sufficiently it will restart automa...

Страница 8: ...leakage from the shaft seal of up to 10 ml per day or 8 to 10 drops per hour may occur Under normal conditions the leaking liquid will evaporate As a result no leakage will be detected When the pump...

Страница 9: ...water CAUTION Impurities in the water Minor or moderate personal injury Do not use the product for drinking water The AISI 316 variant of the JP pump is especially suitable for pool cleaning applicat...

Страница 10: ...us personal injury Make sure that the product has only been used for water If the product has been used for pumping aggressive liquids flush the system with clean water before you start work on the pr...

Страница 11: ...72420 Related information 7 Taking the product out of operation 7 2 Draining JP PT H To drain JP Booster with a horizontal pressure tank do as follows 1 Drain the pump by removing the drain plug 2 Uns...

Страница 12: ...at a high pressure Remedy Clean the pipe or open the isolating valves if any Cause The pump is not filled with water Remedy Prime the pump Cause The inlet pipe is blocked by impurities Remedy Clean t...

Страница 13: ...e sure that the built in circuit breaker of the pump is switched off Cause The motor protection of the pump has tripped due to overload Remedy Make sure the motor or pump is not blocked Cause The pump...

Страница 14: ...P 5 48 1 0 bar 0 10 MPa 9 4 Miscellaneous data Cut in pressure Preset cut in pressure start pressure JP PM 1 5 bar JP PT V 2 2 bar JP PT H 2 2 bar Min max storage temperature 20 70 C 10 Disposing of t...

Страница 15: ...9 3 3 22 4 24 4 1 24 4 2 24 5 25 5 1 JP 25 5 2 JP Booster 26 5 3 26 5 4 26 5 5 26 6 27 6 1 27 6 2 27 6 3 27 7 27 7 1 JP JP PT V 28 7 2 JP PT H 28 7 3 28 7 4 28 8 28 8 1 29 8 2 29 8 3 29 8 4 29 8 5 e 3...

Страница 16: ...1 1 2 3 JP Booster 1 Grundfos JP Booster 1 1 3 3 1 3 1 2 3 1 1 3 1 2 55 C 40 C 40 55 C 20 40 S3 40 55 C 50 Hz 60 Hz JP 3 42 20 40 20 40 JP 4 47 15 45 10 50 JP 4 54 20 40 20 40 JP 5 48 20 40 30 30 3 1...

Страница 17: ...F G TM072477 JP PT H JP mm JP PT H mm F 47 265 G 110 230 3 2 2 JP 2 1 1x 2x 1 1 TM072418 2 4 1 2 3 TM072419 4 TM072480 3 2 3 1 10 m 4 m 1 2 3 4 5 5 TM064532 3 2 3 1 3 2 3 2 20 BG...

Страница 18: ...rea Ltd 6th Floor Aju Building 679 5 Yeoksam dong Kangnam ku 135 916 Seoul Korea Tel 82 2 5317 600 Fax 82 2 5633 725 Latvia SIA GRUNDFOS Pumps Latvia Deglava biznesa centrs Augusta Deglava iel 60 LV 1...

Страница 19: ...emarks displayed in this material including but not limited to Grundfos the Grundfos logo and be think innovate are registered trademarks owned by The Grundfos Group All rights reserved 2018 Grundfos...

Отзывы: