background image

2.3 Scope of delivery, JP Booster

The box contains the following items:

1 Grundfos JP Booster

1 quick guide

1 safety instructions booklet.

3. Installing the product

3.1 Location

The product can be installed both indoors and outdoors. Use a
suitable cover to protect the product from direct sunlight, rain or
snow.

Please observe the following:

Install the product in a well-ventilated location to ensure cooling
of its components.

Install the product to enable easy inspection, maintenance and
service.

We recommend that you place the product as close to the
liquid to be pumped as possible.

We recommend that you install the product near a drain or in a
drip tray connected to a drain in order to lead away possible
condensation from cold surfaces.

Related information

3.1.2 Ambient temperature during operation

3.1.1 Installation of the product in a frosty environment

Protect the product from freezing if it is to be installed outdoors
where frost may occur.

3.1.2 Ambient temperature during operation

The ambient temperature must not exceed 55 °C.

Ambient temperature

Up to 40
°C

The pump can run continuous operation.

40 to 55
°C

The overheating protection ensures that the pump
runs intermittent operation when the air temperature
is too high to cool the motor efficiently.
Example of intermittent cycle: the pump runs for 20
minutes and stops for 40 minutes before it starts
again. See the table below.

Intermittent operation (S3 mode)

40-55 °C

50 Hz

60 Hz

JP 3-42

ON: 20 min
OFF: 40 min

ON: 20 min
OFF: 40 min

JP 4-47

ON: 15 min
OFF: 45 min

ON: 10 min
OFF: 50 min

JP 4-54

ON: 20 min
OFF: 40 min

ON: 20 min
OFF: 40 min

JP 5-48

ON: 20 min
OFF: 40 min

ON: 30 min
OFF: 30 min

Related information

3.1 Location

3.1.3 Minimum space

Ensure sufficient space for service and maintenance and for motor
cooling.

We recommend a clearance of 0.5 m on three sides of the
product.

The motor is fan cooled, so do not block the fan cover.

If you install the product with one side against a wall, make
sure that the nameplate is visible.

3.2 Mechanical installation

WARNING
Electric shock 

Death or serious personal injury

Switch off the power supply before you start any work
on the product.Make sure that the power supply cannot
be switched on accidentally.

CAUTION
Crushing of feet 

Minor or moderate personal injury

Wear safety shoes when handling the product.

CAUTION
Impurities in the water

Minor or moderate personal injury

Before the pump is used for supplying drinking water,
flush the pump thoroughly with clean water.

3.2.1 Mounting the product

Place the product in a horizontal position with a maximum
inclination angle of ± 5 °. The base plate must be facing
downwards.

Fasten the product to a solid horizontal foundation by means of
screws through the holes in the base plate.

F

G

TM072334

Fig.

Foundation of a JP pump

F

G

TM072477

Fig.

Foundation of JP PT-H Booster

JP pump

[mm]

JP PT-H Booster

[mm]

F

47

265

G

110

230

3.2.2 Attaching the lifting handle

The handle is supplied with the JP pump. It is optional to attach the
handle on the pump, for example on permanently installed pumps.

6

English (GB)

Содержание JP 3-42

Страница 1: ...JP and JP Booster Installation and operating instructions GRUNDFOS INSTRUCTIONS...

Страница 2: ...his document before you install the product Installation and operation must comply with local regulations and accepted codes of good practice 1 1 Target group These installation and operating instruct...

Страница 3: ...40 55 C 50 Hz 60 Hz JP 3 42 ON 20 min OFF 40 min ON 20 min OFF 40 min JP 4 47 ON 15 min OFF 45 min ON 10 min OFF 50 min JP 4 54 ON 20 min OFF 40 min ON 20 min OFF 40 min JP 5 48 ON 20 min OFF 40 min...

Страница 4: ...esigned for the maximum pump pressure The maximum inlet pressure depends on the head at the actual duty point The sum of the inlet pressure and the head must not exceed the maximum system pressure We...

Страница 5: ...Electrical connection WARNING Electric shock Death or serious personal injury Switch off the power supply before you start any work on the product Make sure that the power supply cannot be switched on...

Страница 6: ...correct terminal in the external main switch Wiring a plug 1 Strip the cable 2 Loosen the two screws holding the cable clamp and pull the cable through 3 Thread each individual wire to the correct ter...

Страница 7: ...ependent motor protection If the pump is running without water is blocked or otherwise overloaded the built in thermal switch will cut out When the motor has cooled sufficiently it will restart automa...

Страница 8: ...leakage from the shaft seal of up to 10 ml per day or 8 to 10 drops per hour may occur Under normal conditions the leaking liquid will evaporate As a result no leakage will be detected When the pump...

Страница 9: ...water CAUTION Impurities in the water Minor or moderate personal injury Do not use the product for drinking water The AISI 316 variant of the JP pump is especially suitable for pool cleaning applicat...

Страница 10: ...us personal injury Make sure that the product has only been used for water If the product has been used for pumping aggressive liquids flush the system with clean water before you start work on the pr...

Страница 11: ...72420 Related information 7 Taking the product out of operation 7 2 Draining JP PT H To drain JP Booster with a horizontal pressure tank do as follows 1 Drain the pump by removing the drain plug 2 Uns...

Страница 12: ...at a high pressure Remedy Clean the pipe or open the isolating valves if any Cause The pump is not filled with water Remedy Prime the pump Cause The inlet pipe is blocked by impurities Remedy Clean t...

Страница 13: ...e sure that the built in circuit breaker of the pump is switched off Cause The motor protection of the pump has tripped due to overload Remedy Make sure the motor or pump is not blocked Cause The pump...

Страница 14: ...P 5 48 1 0 bar 0 10 MPa 9 4 Miscellaneous data Cut in pressure Preset cut in pressure start pressure JP PM 1 5 bar JP PT V 2 2 bar JP PT H 2 2 bar Min max storage temperature 20 70 C 10 Disposing of t...

Страница 15: ...9 3 3 22 4 24 4 1 24 4 2 24 5 25 5 1 JP 25 5 2 JP Booster 26 5 3 26 5 4 26 5 5 26 6 27 6 1 27 6 2 27 6 3 27 7 27 7 1 JP JP PT V 28 7 2 JP PT H 28 7 3 28 7 4 28 8 28 8 1 29 8 2 29 8 3 29 8 4 29 8 5 e 3...

Страница 16: ...1 1 2 3 JP Booster 1 Grundfos JP Booster 1 1 3 3 1 3 1 2 3 1 1 3 1 2 55 C 40 C 40 55 C 20 40 S3 40 55 C 50 Hz 60 Hz JP 3 42 20 40 20 40 JP 4 47 15 45 10 50 JP 4 54 20 40 20 40 JP 5 48 20 40 30 30 3 1...

Страница 17: ...F G TM072477 JP PT H JP mm JP PT H mm F 47 265 G 110 230 3 2 2 JP 2 1 1x 2x 1 1 TM072418 2 4 1 2 3 TM072419 4 TM072480 3 2 3 1 10 m 4 m 1 2 3 4 5 5 TM064532 3 2 3 1 3 2 3 2 20 BG...