34

35. Insert the O-ring 72a into the motor stool 2.

Fig. 51 

O-ring

36. Unload the spring of the mechanical seal 105 

against the seal spacer 61.
Use the ejector from Grundfos FB Pump tool kit 
(pos. 2, fig. 55)
Applies to open spring mechanical seal only.

37. Fit the pump housing 6.

Adjust the pump housing 6 via discharge branch 
by using a spirit level.

Fig. 52 

Adjusting pump housing

38. Assemble the upper and lower clamp ring 92a 

and 92b onto the housing / motor stool.
Use a soft hammer (mallet) to tap the clamp ring 
into place ensuring it sits properly in place over 
the flanges on the housing and motor stool.

39. Grease the tie bolt 93.

Recommend Klüberpaste UH1 96-402 or 
equivalent.
Tighten hexagon nut 94 and washer 94c onto tie 
bolt 93 to do this.
Torque: 
M10 - 26 lbf ft (35 Nm).

Fig. 53 

Closing clamp ring

40. Assemble coupling guard.

Use hexagon head screws 7a.

Fig. 54 

Coupling guard

  

 

  

   

 

  

 

Содержание FB 10/40

Страница 1: ...GRUNDFOS INSTRUCTIONS FB Installation and operating instructions...

Страница 2: ......

Страница 3: ...________________________________12 3 3 2 Minimum flow rate Qmin___________________________________________________12 3 3 3 Connections and pipelines ________________________________________________12...

Страница 4: ...__________________________ 26 6 4 3 Disassembly of the pump _________________________________________________ 27 6 4 4 Assembly of the pump ___________________________________________________ 30 6 5 T...

Страница 5: ...c sequence are numbered in the corresponding order Important information and helpful tips are identified with the index finger symbol Safety instructions The system used to identify safety instruction...

Страница 6: ...e for the pump must therefore read this manual before installing and starting the pump The operating manual must always be available at the site where the pump is being used Both safety instructions p...

Страница 7: ...ch has been switched off It must be ensured that the electricity supply cannot be accidentally switched on 2 4 Qualifications and training of personnel The employees operating maintaining inspecting a...

Страница 8: ...before next start up CAUTION Tripping hazard from electric power cable S Death serious bodily injury Z Route the electric power cable in such a way that no one can trip over it in case of portable pu...

Страница 9: ...izontally when it is lifted ATTENTION Incorrect lifting points S Damage to property Z Fasten the rope to suitable lifting points Z Never fasten a rope to the pump casing or suction discharge branch 2...

Страница 10: ...al protection means that all commercial enterprises must protect their employees the public at large and the environment from the harmful effects of hazardous materials Example of legal regulations on...

Страница 11: ...ard design Pumps of the standard design are typically used for systems and processes involved in the food product dairy and beverage industries Overview This section describes the pump and it s design...

Страница 12: ...necting elements to the pump must conform exactly to the design standard specification of the mating connector piece installed on the pump The suction line must be absolutely leak tight and laid in su...

Страница 13: ...surface finish E EPDM V FKM A o ring seal with enclosed spring enclosed spring seal required for 3 A compliance C o ring seal with open spring driver for non sanitary industrial applications only Q q...

Страница 14: ...ly injury damage to property Z Never exceed the specified operating temperatures 3 4 5 Maximum operating pressure WARNING Pressure overload S Damage to property Z Never exceed the specified maximum op...

Страница 15: ...ort the pipeline Z In addition to the general rules of machine building and plant construction also follow the instructions provided by the manufacturer of the connecting elements used e g flanges whe...

Страница 16: ...head of the system may not be greater than the head guaranteed by the pump Z The nominal pipeline diameters of the system should be equal to or greater than the DNS or DND connectors of the pump Z A f...

Страница 17: ...sure not to re absorb warm cooling air Consider other heat sources in the area Pay attention to motor power Keep the minimum distances Fig 6 Installation in the pipeline above gravity feed mode below...

Страница 18: ...tightness of connections 4 4 Electrical connections WARNING Electric shock S Death serious bodily injury Z The electrical connections must be made by a qualified electrician Z Specifications and any...

Страница 19: ...tion side 8 Close the control valve on the discharge side 9 Start the pump 10 Slowly open the control valve on discharge side CAUTION Overheating and pressure overloading S Damage to property Z Never...

Страница 20: ...w in the discharge pipe In case of a pressure surge the pressure is rised to many times of the max permitted pump pressure Shut down the pump in this way 1 Close the control valve on the discharge sid...

Страница 21: ...to the plant and pump Z Depressurize the pump before eliminating any breakdown WARNING Hot components S Death bodily injury or damage to the plant and pump Z Always allow to cool down before eliminat...

Страница 22: ...ort surfaces and other auxiliary materials must ensure that all parts of the pump can be assembled without damage e g scratches See chapter 6 7 CAUTION Frost S Damage to property Z When there is dange...

Страница 23: ...sassembly 6 4 1 Parts Overview See parts list on page 24 Fig 9 Overview FB K 0348V2 9 9c 10a 10b 11 51 310 151b 90a 90f 90b 90j 90h 6 67 66 67b 49 105 72a 92b 93 23d 28 92a 94c 94 76a 76 23 23d 7a 7 2...

Страница 24: ...elastomer individually packaged part see tab 3 line 7 10 seal kit see tab 4 line 1 and 3 1 72a O Ring elastomer individually packaged part see tab 3 line 7 10 1 76 name plate 2 76a round head grooved...

Страница 25: ...individually packaged FKM o ring Pos 72a 96942035 96942036 Tab 3 Service component kits Line Seal assemblies spring type enclosed spring open spring seal typea ASCE ASCV AQQE AQQV CSCE CSCV CQQE CQQV...

Страница 26: ...it in order to assemble the pump without damage and scratches Z To guarantee a good seal use only O ring seals with the original dimensions Z Never use grease which contains mineral oil when assemblin...

Страница 27: ...Remove clamp ring assembly 92a 92b Fig 13 Clamp ring 3 Unscrew the hexagon head screw 7a and remove the coupling guard 7 Fig 14 Coupling guard 4 Unscrew impeller nut 67 Use a socket wrench pos 4 or 5...

Страница 28: ...ies to an open spring mechanical seal only Fig 19 Seal spacer 9 Remove the O ring 109 out of the seal spacer 61 Fig 20 O ring 10 Remove the O ring 72a Fig 21 O ring 11 Remove rotary ring of the mechan...

Страница 29: ...quenched seal is fitted spray clean water on the shaft to assist the lip seal to slide along the shaft Remove the motor stool 2 from the motor Fig 24 Motor stool 14 Remove the lip seal 105c out of th...

Страница 30: ...ons and water rinses with the aid of one or more of a combination of brushes non metallic scouring pads and scrapers See page 37 for the optional assembly tools mentioned in the following description...

Страница 31: ...on the shaft The enclosed spring mechanical seal has the spacer built into the drive sleeve portion of the mechanical seal so this drive sleeve can be used in place of the spacer 61 when setting the...

Страница 32: ...nnection and assemble it again or use an appropriate tool to adjust soft mallet Fig 40 Sensing head 20 Spray clean water onto the pump shaft 51 to assist the seal assembly 21 Push the stationary ring...

Страница 33: ...impeller 66 impeller lock washers fine teeth facing outwards coarse teeth together 67 impeller nut 67b O ring 31 Grease the thread of the pump shaft 51 Recommend Kl berpaste UH1 96 402 or equivalent F...

Страница 34: ...it level Fig 52 Adjusting pump housing 38 Assemble the upper and lower clamp ring 92a and 92b onto the housing motor stool Use a soft hammer mallet to tap the clamp ring into place ensuring it sits pr...

Страница 35: ...ix the problem 2 Install the pump so that there is no stress on it Support the pipelines at fixed points 3 Set the operating point according to the data sheet 4 If it is acceptable for the performance...

Страница 36: ...ect and clean the rotating mechanical seal 4 Replace mechanical seal 5 Tighten the stuffing box packing add more packing or replace the packing 6 Replace the shaft or the shaft safety sleeve 7 Use an...

Страница 37: ...mp tool kit K 0390V1 Position Description Part no 1a Seal assembly sleeve 19mm 97513481 1b Seal assembly sleeve 28mm 97513482 2 Seal ring ejector tool 97513483 3 Kl berpaste UH1 96 402 97513484 4 32 x...

Страница 38: ...1 Certificate of cleanliness Fig 56 Certificate of cleanliness Overview This section gives information concerning the certificate of cleanliness In case of inspection or repairing send the pump inclu...

Страница 39: ...by the manufacturer of said products and not by Grundfos warranty Grundfos will not be liable for damage or wear to products caused by abnormal operating conditions accident abuse misuse unauthorized...

Страница 40: ...GRUNDFOS INSTRUCTIONS L FB TL 001 02 10 US 10 09 www grundfos com Being responsible is our foundation Thinking ahead makes it poss ble Innovation is the essence...