9. Delivery, transport and storage
If the controller is not already mounted on the pump set, it is
delivered from the factory in an open wooden crate on a pallet.
In order to prevent damage to the controller, leave the control
cabinet in the packaging until installation.
Storage temperature: 0-40 °C.
Relative humidity:
95 %, not condensing.
10. Installation
10.1 Mechanical installation
The controller is only suitable for indoor installation. It must not be
exposed to direct sunlight and must be installed in a dry, well-
ventilated but frost-free room.
The controller must be placed as close to the pump as possible
and within view of the pump set. Ensure sufficient space for
installation and subsequent access to the controller and its
components, and make sure that the device is installed at the
correct height. Make sure there is sufficient air circulation for
cooling.
There are three mounting options:
1. mounting on the pump set
2. mounting on the wall
3. mounting on the floor.
Mounting on the wall or floor
Mount the control cabinet on the wall or floor near the pump set
by means of screws. Drill holes into the wall or floor according to
the drilling template on the back or pedestals of the control
cabinet, and use dowels and screws of adequate size.
Mounting on the pump set
Pump sets delivered by Grundfos have a special retainer for the
control cabinet. Mount the control cabinet in the retainer by
means of suitable screws and nuts.
10.2 Electrical connection
Carry out the electrical connection according to local regulations.
Check that the supply voltage and frequency correspond to the
values stated on the nameplate.
The electrical connection must be made in accordance with the
wiring diagram in the control cabinet.
10.2.1 Compact version
For the Compact version of the fire pump set, the controller is
mounted on the base frame and the electric motor is already
connected.
Procedure
• The connection to the mains supply must be fitted with a fuse
of the correct size, in accordance with local regulations, and
connected to the main switch in the control cabinet. PE must
be connected using the PE terminal block.
• Pressure switch 1 must be connected to terminals 6 and 7 in
the control cabinet, and pressure switch 2 to terminals 8
and 9.
• The additional pressure switch for the "Pump running"
indication is to be connected to terminals 12 and 13.
• If there is a level switch for measuring the filling level in the
priming tank, it must be connected to terminals 10 and 11.
• If status and alarm indications are to be transmitted to a
building management system, terminals 31 to 40 must be used
for this purpose.
10.2.2 Flex version
For the Flex version of the fire pump set, the controller cabinet
designed to be mounted on a wall is delivered separately.
In addition to the electric connections described in
section
, the electric motor cables in the
controller cabinet must be connected to terminals U1, V1, W1
and U2, V2, W2 of the terminal blocks.
Note
Check the controller carefully on delivery, and
transport and store it correctly before
installation.
Caution
The controller must only be transported in the
packaging. Use only suitable lifting equipment
that is in good condition.
Warning
The controller must be installed and connected in
accordance with local regulations and by
qualified personnel.
Warning
Installation and operation in a potentially
explosive environment are not permissible.
Warning
The control cabinet must be placed so that water
from the pump or pipework cannot pose any
danger.
Caution
Use only suitable lifting equipment that is in
good condition. Close the cabinet door before
transporting the control cabinet. Pinch hazard!
Warning
When drilling holes, make sure not to damage
any wires or water and gas pipes. Furthermore,
ensure safe installation.
Warning
During electrical installation, make sure that the
power supply cannot be accidentally switched
on.
Содержание EPC 300
Страница 1: ...GRUNDFOS INSTRUCTIONS Fire Control EN electric 55 kW Installation and operating instructions...
Страница 2: ...2...
Страница 23: ...BG 23 8 4 8 1 TM05 0744 1511 Test Test 1 2...
Страница 24: ...BG 24 8 2 Status 8 3 Alarms AR1 AR2 AR3 1 2 P1 P1 AR1 AR4 DI4 AR5...
Страница 26: ...BG 26 11 10 1 I 2 Test 3 4 Start 8 3 15 5 6 25 Nm 1 2 30 Nm 3 8 7 Stop 8 Auto 9...
Страница 27: ...BG 27 12 8 2 15 12 1 Auto I Auto Test Stop O I 1 2...
Страница 28: ...BG 28 12 2 1 I 2 Test 3 4 Start 15 1 Stop 2 Auto 3...
Страница 29: ...BG 29 12 3 1 Test 2 3 P1 4 Stop 5 P2 6 12 2...
Страница 30: ...BG 30 13 14 5 Grundfos 5 12 2 1 2 3 4 EN TM05 4262 2112...
Страница 32: ...BG 32 16 Grundfos Grundfos 17 18 1 2 Grundfos Grundfos Grundfos...