6.5 Fitting impeller and pump housing
Fig. 13
Impeller and pump housing assembly and impeller clearance
1. Fit and lubricate the O-ring (37 or 39) on the pump housing
(50).
2. Fit the pump housing (50) and tighten the screws (184)
according to torques in the table in section
3. Fit spacer rings (49a) to the shaft.
4. Fit the key (9a) in the shaft.
5. Fit the impeller (49) on the shaft and tighten the nut (188)
according to torques in the table in section
6. Fit the inlet cover (189) to the pump housing and tighten the
screws (188a) according to torques in the table in section
7. Check the impeller clearance. See fig.
. The impeller
clearance must be between 0.3 and 0.5 mm. If the impeller
clearance is outside this range, dismantle the impeller and
add or remove spacer rings to obtain the right clearance. Then
check the clearance again.
8. Fit the inlet strainer or ring stand (84a) and tighten the screws
(35) according to torques in the table in section
TM
07
39
73
06
19
0.3 - 0.5 mm
Содержание DPK
Страница 1: ...DPK DPK 0 75 22 kW 50 60 Hz 1 3 Service instructions GRUNDFOS INSTRUCTIONS...
Страница 17: ...English GB 17 8 1 DPK 10 50 075 DPK 10 50 15 and DPK 10 80 22 TM04 4365 4214...
Страница 21: ...English GB 21 8 5 DPK V 65 80 15 2 and DPK V 65 80 22 2 TM06 5610 5215...
Страница 22: ...English GB 22 8 6 DPK V 80 80 37 2 TM06 5428 4915...
Страница 23: ...English GB 23 8 7 DPK V 80 80 55 2 and DPK V 80 80 75 2 TM06 5430 5215...
Страница 24: ...English GB 24 8 8 DPK V 65 80 15 4 and DPK V 65 80 22 4 TM06 5608 5215...
Страница 25: ...English GB 25 8 9 DPK V 80 80 37 4 DPK V 80 80 55 4 and DPK V 80 80 75 4 TM06 5609 5215...
Страница 26: ...26...