Electronics Diaphragm Breakage Sensor
7.1
Technical Data of the Electronics
Description
Model 230 V (+10% /-10%)
Model 115 V (+10% /-10%)
Contact load
250 V / 6 A, max. 550VA
Power consumption
1.15 VA
Degree of protection
IP 65
Permissible temperature range
0 - 40 °C
7.2
Dimensional Drawing (Electronics Enclosure)
130
113.5
63.
5
80
7.2
Function
7.2.1 Pumps prepared for a diaphragm breakage indication
❏
Special dosing head flange for inserting the optoelectronic sensor
❏
Optoelectronic sensor, contains
-
infrared sender
-
infrared receiver
In case of a leaking diaphragm:
❏
Dosing liquid penetrates the dosing head flange.
-
The light refraction will be changed.
❏
The sensor produces a signal.
-
The electronics switches two contacts which can be used e. g. for
triggering an alarm device or switching off the pump.