background image

En
gl

is

h (
G

B)

4

3. Service

3.1 Perform service

3.1.1 Dismantling the diaphragm and valves

3.1.2 Reassembling the diaphragm and valves

3.2 Diaphragm breakage

3.2.1 Dosing liquid in the pump housing

3.3 Operation with loose dosing head 

screws

3.4 Repairs

4. Disposal

The crossed-out wheelie bin symbol on 
a product means that it must be 
disposed of separately from household 
waste. When a product marked with this 
symbol reaches its end of life, take it to a 
collection point designated by the local 

waste disposal authorities. The separate collection 
and recycling of such products will help protect the 
environment and human health.

Warning
Risk of chemical burns!
When dosing dangerous media, observe 
the corresponding precautions in the 
safety data sheets!
Wear protective clothing (gloves and 
goggles) when working on the dosing 
head, connections or lines!
Do not allow any chemicals to leak from 
the pump. Collect and dispose of all 
chemicals correctly!

Caution

Before any work to the pump, the pump 
must be disconnected from the power 
supply. The system must be pressureless!

Warning
Danger of explosion, if dosing liquid has 
entered the pump housing!
If the diaphragm is possibly damaged or if 
the pump was operated with damaged or 
loose dosing head screws, don’t connect 
the pump to the power supply!

Caution

Cross-tighten the dosing head screws with 
a torque wrench once before 
commissioning and again after 2-5 
operating hours at 5.5 Nm (+ 0.5/- 0 Nm).

Warning
Danger of explosion, if dosing liquid has 
entered the pump housing!
Operation with damaged diaphragm can 
lead to dosing liquid entering the pump 
housing.
In case of diaphragm breakage, 
immediately separate the pump from the 
power supply!
Make sure the pump cannot be put back 
into operation by accident!
Dismantle the dosing head without 
connecting the pump to the power supply 
and make sure no dosing liquid has 
entered the pump housing.

Warning
Danger of explosion!
Immediately separate the pump from the 
power supply!
Make sure the pump cannot be put back 
into operation by accident!

Warning
Danger of explosion, if dosing liquid has 
entered the pump housing!
Operation with damaged or loose dosing 
head screws can lead to dosing liquid 
entering the pump housing.
If the pump was operated with damaged or 
loose dosing head screws, immediately 
separate the pump from the power supply!
Make sure the pump cannot be put back 
into operation by accident!
Dismantle the dosing head without 
connecting the pump to the power supply 
and make sure no dosing liquid has 
entered the pump housing.

Warning
The pump housing must only be opened 
by personnel authorised by Grundfos!
Repairs must only be carried out by 
authorised and qualified personnel!
Switch off the pump and disconnect it from 
the voltage supply before carrying out 
maintenance work and repairs!

Note

The replacement of the supply cable must 
be carried out by an authorised Grundfos 
service workshop.

Caution

The pump must be cleaned prior to 
dispatch!
If dosing liquid has possibly entered the 
pump housing, state that explicitly in the 
safety declaration!

Содержание DME AP

Страница 1: ...tion and operating instructions GRUNDFOS INSTRUCTIONS Installation and operating instructions DME B http net grundfos com qr i 99301275 Installation and operating instructions DME AR and AP http net grundfos com qr i 99301274 ...

Страница 2: ...rer s safety data sheets and safety instructions when handling chemicals Warning The pump must be equipped with a diaphragm leakage detection when used for crystallising media Caution A deaeration hose which is routed into a container e g a drip tray must be connected to the deaeration valve Caution The dosing medium must be in liquid aggregate state Observe the freezing and boiling points of the ...

Страница 3: ... number of seconds at maximum capacity The remaining number of seconds will appear in the display The maximum value is 300 seconds 2 2 Installation of pump 2 3 Electrical connection Warning Other applications or the operation of pumps in ambient and operating conditions which are not approved are considered improper and are not permitted Grundfos cannot be held liable for any damage resulting from...

Страница 4: ...5 5 Nm 0 5 0 Nm Warning Danger of explosion if dosing liquid has entered the pump housing Operation with damaged diaphragm can lead to dosing liquid entering the pump housing In case of diaphragm breakage immediately separate the pump from the power supply Make sure the pump cannot be put back into operation by accident Dismantle the dosing head without connecting the pump to the power supply and ...

Страница 5: ...error in brief We hereby declare that the pump has been cleaned and is completely free from chemical biological and radioactive substances _____________________________________ Date and signature _____________________________________ Company stamp Note Fill in this document using english or german language Product type nameplate Model number nameplate Dosing medium TM02 8957 0315 Dosing liquid has...

Страница 6: ... questa dichiarazione è conforme alle seguenti direttive del Consiglio riguardanti il riavvicinamento delle legislazioni degli Stati membri UE LT ES atitikties deklaracija Mes Grundfos su visa atsakomybe pareiškiame kad produktas DME kuriam skirta ši deklaracija atitinka žemiau nurodytas Tarybos Direktyvas dėl ES šalių narių įstatymų suderinimo LV ES atbilstības deklarācija Sabiedrība Grundfos ar ...

Страница 7: ...2015 EN 61000 3 3 2014 RoHS Directives 2011 65 EU and 2015 863 EU Standard used EN 50581 2012 This EU declaration of conformity is only valid when published as part of the Grundfos safety instructions publication numbers 99270841 Pfinztal 1 May 2019 Werner Baumann R D Manager Grundfos Water Treatment GmbH Reetzstr 85 D 76327 Pfinztal Germany Person authorised to compile technical file and empowere...

Страница 8: ...ʽ ˀ ˁ ϬϮϬ ϮϬϭϭ ˑ KAZ DME AR DME AP ɉɚɣɞɚɥɚɧɭ ɛɨɣɵɧɲɚ ɧԝɫԕɚɭɥɵԕ ʤ ಢ ಱ ದ ದ ದಱ ಱ ϭ ʿ ಱ ದ ದ Ϯ ʧ ಪ ದ ದಱ ౢಱ ಱ ದ ದ ౢಱ ಪ ದ ಪ ϯ ಪ ದ ದ ದ ಢ ಢ ದ ˁ ದ DME AR DME W ಢ ದ ಪ ದ ˀ ˁ ϬϬϰ ϮϬϭϭͿ ʺ ದ ದ ˀ ˁ ϬϭϬ ϮϬϭϭͿ ದ ಪ ˀ ˁ ϬϮϬ ϮϬϭϭͿ ʶ ʽ ಢ ಪ ದ ಪ KG DME AR DME AP ɉɚɣɞɚɥɚɧɭɭ ɛɨɸɧɱɚ ɤɨɥɞɨɧɦɨ ʤ ರ ರ ರ ϭ ʥ ರ ʿ 2 ʥ ರ ʿ ʿ ರ ರ ʧ ʪ ರ ಪ ϯ ʥ ರ ರ ˌ ರ DME AR DME W ರ ರ ರ ʥ ʥ ˀ ʥ ϬϬϰ ϮϬϭϭ ರ ˀ ʥ ϬϭϬ ϮϬϭϭ ʮ ರ ˀ ʥ ϬϮϬ ϮϬϭϭ ...

Страница 9: ...ʏʕ ɝɸʔ 3 ʖɼʉɼʆʏʙʀʌʏʙʍ ɸʗʖɸɻʗʋɸʍ ɸʋʔɸʀʕʂ ʕɼʗɸɹɼʗʌɸʃɵ ʍʎʕɸʅ ʔɸʗʛɸʕʏʗʋɸʍ ʑʂʖɸʆʂ ʕʗɸ ɨɼʉɼʆʏʙʀʌʏʙʍʍɼʗ ʇɸʕɸʔʖɸɺʗʋɸʍ ʋɸʔʂʍɵ DME AR DME AP ʖʂʑʂ ʑʏʋʑɼʗɿ ʔɼʗʖʂʝʂʆɸʘʕɸʅ ɼʍ ʇɸʋɸʈɸʌʍ ɝɸʛʔɸʌʂʍ ɝʂʏʙʀʌɸʍ ʖɼʄʍʂʆɸʆɸʍ ʆɸʍʏʍɸʆɸʗɺʂ ʑɸʇɸʍʒʍɼʗʂɵ ǺǸ Ǻǹ ɪɸʅʗɸʕʏʃʖ ʔɸʗʛɸʕʏʗʏʙʋʍɼʗʂ ʕɼʗɸɹɼʗʌɸʃª ǺǸ Ǻǹ ɝɼʛɼʍɸʍɼʗʂ ʞ ʔɸʗʛɸʕʏʗʏʙʋʍɼʗʂ ɸʍʕʖɸʍɺʏʙʀʌɸʍ ʕɼʗɸɹɼʗʌɸʃ ǺǸ Ǻǹ ɨɼʄʍʂʆɸʆɸʍ ʋʂʒʏʘʍɼʗʂ ɾʃɼʆʖʗɸʋɸɺʍʂʔɸʆɸʍ ʇɸʋɸʖɼʉɼʃʂʏʙʀʌɸʍ ʕɼʗɸɹɼʗʌɸʃ ...

Страница 10: ...Ϭ ϮϬϭϭ ˑ KAZ DME B ɉɚɣɞɚɥɚɧɭ ɛɨɣɵɧɲɚ ɧԝɫԕɚɭɥɵԕ ʤ ಢ ಱ ದ ದ ದಱ ಱ ϭ ʿ ಱ ದ ದ Ϯ ʧ ಪ ದ ದಱ ౢಱ ಱ ದ ದ ౢಱ ಪ ದ ಪ ϯ ಪ ದ ದ ದ ಢ ಢ ದ ˁ ದ DME B ಢ ದ ಪ ದ ˀ ˁ ϬϬϰ ϮϬϭϭͿ ʺ ದ ದ ˀ ˁ ϬϭϬ ϮϬϭϭͿ ದ ಪ ˀ ˁ ϬϮϬ ϮϬϭϭͿ ʶ ʽ ಢ ಪ ದ ಪ KG DME B ɉɚɣɞɚɥɚɧɭɭ ɛɨɸɧɱɚ ɤɨɥɞɨɧɦɨ ʤ ರ ರ ರ ϭ ʥ ರ ʿ 2 ʥ ರ ʿ ʿ ರ ರ ʧ ʪ ರ ಪ ϯ ʥ ರ ರ ˌ ರ DME B ರ ರ ರ ʥ ʥ ˀ ʥ ϬϬϰ ϮϬϭϭ ರ ˀ ʥ ϬϭϬ ϮϬϭϭ ʮ ರ ˀ ʥ ϬϮϬ ϮϬϭϭ ...

Страница 11: ...ʏʕ ɝɸʔ 3 ʖɼʉɼʆʏʙʀʌʏʙʍ ɸʗʖɸɻʗʋɸʍ ɸʋʔɸʀʕʂ ʕɼʗɸɹɼʗʌɸʃɵ ʍʎʕɸʅ ʔɸʗʛɸʕʏʗʋɸʍ ʑʂʖɸʆʂ ʕʗɸ ɨɼʉɼʆʏʙʀʌʏʙʍʍɼʗ ʇɸʕɸʔʖɸɺʗʋɸʍ ʋɸʔʂʍɵ DME B ʖʂʑʂ ʑʏʋʑɼʗɿ ʔɼʗʖʂʝʂʆɸʘʕɸʅ ɼʍ ʇɸʋɸʈɸʌʍ ɝɸʛʔɸʌʂʍ ɝʂʏʙʀʌɸʍ ʖɼʄʍʂʆɸʆɸʍ ʆɸʍʏʍɸʆɸʗɺʂ ʑɸʇɸʍʒʍɼʗʂɵ ǺǸ Ǻǹ ɪɸʅʗɸʕʏʃʖ ʔɸʗʛɸʕʏʗʏʙʋʍɼʗʂ ʕɼʗɸɹɼʗʌɸʃª ǺǸ Ǻǹ ɝɼʛɼʍɸʍɼʗʂ ʞ ʔɸʗʛɸʕʏʗʏʙʋʍɼʗʂ ɸʍʕʖɸʍɺʏʙʀʌɸʍ ʕɼʗɸɹɼʗʌɸʃ ǺǸ Ǻǹ ɨɼʄʍʂʆɸʆɸʍ ʋʂʒʏʘʍɼʗʂ ɾʃɼʆʖʗɸʋɸɺʍʂʔɸʆɸʍ ʇɸʋɸʖɼʉɼʃʂʏʙʀʌɸʍ ʕɼʗɸɹɼʗʌɸʃ ŚƚƚƉ ŶĞƚ...

Страница 12: ... 1 2913444 Telefax 57 1 8764586 Croatia GRUNDFOS CROATIA d o o Buzinski prilaz 38 Buzin HR 10010 Zagreb Phone 385 1 6595 400 Telefax 385 1 6595 499 www hr grundfos com GRUNDFOS Sales Czechia and Slovakia s r o Čapkovského 21 779 00 Olomouc Phone 420 585 716 111 Denmark GRUNDFOS DK A S Martin Bachs Vej 3 DK 8850 Bjerringbro Tlf 45 87 50 50 50 Telefax 45 87 50 51 51 E mail info_GDK grundfos com www ...

Страница 13: ...Beograd Phone 381 11 2258 740 Telefax 381 11 2281 769 www rs grundfos com Singapore GRUNDFOS Singapore Pte Ltd 25 Jalan Tukang Singapore 619264 Phone 65 6681 9688 Telefax 65 6681 9689 Slovakia GRUNDFOS s r o Prievozská 4D 821 09 BRATISLAVA Phona 421 2 5020 1426 sk grundfos com Slovenia GRUNDFOS LJUBLJANA d o o Leskoškova 9e 1122 Ljubljana Phone 386 0 1 568 06 10 Telefax 386 0 1 568 0619 E mail teh...

Страница 14: ...1656 Trademarks displayed in this material including but not limited to Grundfos the Grundfos logo and be think innovate are registered trademarks owned by The Grundfos Group All rights reserved 2019 Grundfos Holding A S all rights reserved ...

Отзывы: