4. Assembly and installation
4.1 Pump assembly
The pump is delivered with a mounting plate.
The mounting plate can be mounted vertically, e.g.
on a wall, or horizontally, e.g. on a tank. It takes just
a few quick steps to firmly secure the pump to the
mounting plate by means of a slot mechanism.
The pump can easily be released from the mounting
plate for maintenance.
4.1.1 Requirements
•
The mounting surface must be stable and must
not vibrate.
•
Dosing must flow upwards vertically.
4.1.2 Align and install mounting plate
•
Vertical installation:
Mounting plate slot
mechanism must be above.
•
Horizontal installation:
Mounting plate slot
mechanism must be opposite the dosing head.
•
The mounting plate can be used as a drill
template, please see fig. 3 for drill hole distances.
Fig. 4
Locate mounting plate
1. Indicate drill holes.
2. Drill holes.
3. Secure mounting plate using four screws,
diameter 5 mm, to the wall, on the bracket or the
tank.
4.1.3 Engage pump in mounting plate
1. Attach the pump to the mounting plate support
clamps and slide under slight pressure until it
engages.
Fig. 5
Engaging the pump
4.2 Hydraulic connection
Important information on installation
•
Observe suction lift and hose diameter,
see section
3.1 Technical data
.
•
Shorten hoses at right angles.
•
Ensure that there are no loops or kinks in the
hoses.
•
Keep suction line as short as possible.
•
Route suction line up towards the suction valve.
•
Installing a filter in the suction line protects the
entire installation against dirt and reduces the
risk of leakage.
Note
For use in Australia:
Installation of this product must
comply with AS/NZS3500!
Certificate of suitability number:
CS9431
c-tick number: N20683
Warning
Install the pump in such a way that the
plug can easily be reached by the
operator during operation! This will
enable the operator to separate the
pump from the mains quickly in case of
emergency!
TM0
4
1
1
62
01
10
Warning
Make sure that you do not damage any
cables and lines during installation!
T
M
0
4
1
1
59
01
10
Warning
Risk of chemical burns!
Wear protective clothing (gloves and
goggles) when working on the dosing
head, connections or lines!
Caution
The dosing head may contain water
from the factory check!
When dosing media which should not
come into contact with water, another
medium must be dosed beforehand!
Caution
Faultless function can only be
guaranteed in conjunction with lines
supplied by Grundfos!
Caution
The lines used must comply with the
pressure limits as per section