In order to ensure the optimum protection of the MAGdrive motor, 
the motor protection should be set in accordance with the follow-
ing guidelines:
1. Set the overload protection to the rated full-load current (I

1/1

of the motor.

2. Start the pump and let it run for half an hour at the required 

duty point.

3. Measure the motor current. If not possible slowly grade down 

the scale indicator until the motor trip point is reached. 

4. The setting of the motor protection must be 5 % higher than 

this value.
The highest permissible setting of the motor protection is the 
rated full load current (I1/1) of the motor.

9. Start-up

Note: Do not start the pump until it has been filled with liquid and 
vented.
1. Open the isolating valve on the suction side of the pump.
2. Close the isolating valve on the discharge side of the pump.
3. Loosen the air vent screw in the pump head.
4. Slowly fill the pump with liquid.
5. Tighten the air vent screw when the pump has been com-

pletely filled with liquid.

6. Slowly open the isolating valve on the discharge side of the 

pump.

7. Start the pump.
8. Check the direction of rotation by means of the motor fan and 

the label on top of the fan cover.

9. After start-up, the pump should be vented again.

Slowly loosen the air vent screw in the pump head.

Warning: 

Pay attention to the direction of the vent hole to 

ensure that the escaping liquid does not cause injury to per-
sons or damage to the motor or other components.

10.When liquid starts running out, tighten the air vent screw 

securely.

10. Maintenance

The pump requires no maintenance if is has been installed 
according to the instructions.

11. Fault finding

See the installation and operating instructions of CR, CRI, CRN.

12. Service

If Grundfos is requested to service such a pump, we must be con-
tacted with details about the pumped liquid, etc. before the pump 
is returned for service. Otherwise we can refuse to accept the 
pump for service.
Possible costs of returning the pump are paid by the customer.

12.1 Other documentation

Service and other documentation for CR pumps can be found at 
www.grundfos.com > International website > WebCAPS - pump 
curves/catalogue/product finder.
If you have any questions, please contact the nearest Grundfos 
company or service workshop.

13. Disposal

This product or parts of it must be disposed of as described in the 
installation and operating instructions of CR, CRI, CRN.

The pump contains powerful magnets that may 
pose a risk of personal injury when servicing the 
pump. The pump should therefore only be dis-
mantled and assembled by authorized personnel.

Subject to alterations.

Grundfos.bk  Page 4  Tuesday, August 23, 2011  11:33 PM

Содержание CRN MAGdrive

Страница 1: ...GRUNDFOS INSTRUCTIONS CRN MAGdrive Installation and operating instructions ...

Страница 2: ...llow limit actions on how long implied warranties may last Therefore the above limitations or exclusions may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from jurisdiction to jurisdiction 2 Symbols used in this document 3 Permanent magnets 4 Product description Grundfos CRN MAGdrive are 100 leakage free sealless pumps The motor torque...

Страница 3: ... pump head 8 Electrical connection The pump must be installed as described in the installation and operating instructions of CR CRI CRN Pumps with motors of 25 and 30 Hp and 4 pole motors 1 5 Hp 1 1 kW and above must be started via a soft starter 8 1 Motor protection As minimum the motor must be connected to an effective elec tronic motor protection with instantaneous release when the max imum set...

Страница 4: ...the pump should be vented again Slowly loosen the air vent screw in the pump head Warning Pay attention to the direction of the vent hole to ensure that the escaping liquid does not cause injury to per sons or damage to the motor or other components 10 When liquid starts running out tighten the air vent screw securely 10 Maintenance The pump requires no maintenance if is has been installed accordi...

Страница 5: ...5 This page intentionally left blank ...

Страница 6: ...6 This page intentionally left blank ...

Страница 7: ...27 3400 Telefax 1 913 227 3500 Canada GRUNDFOS Canada Inc 2941 Brighton Road Oakville Ontario L6H 6C9 Phone 1 905 829 9533 Telefax 1 905 829 9512 México Bombas GRUNDFOS de México S A de C V Boulevard TLC No 15 Parque Industrial Stiva Aeropuerto Apodaca N L C P 66600 Phone 52 81 8144 4000 Telefax 52 81 8144 4010 ...

Страница 8: ...makes it possible Innovation is the essence The name Grundfos the Grundfos logo and the payoff Be Think Innovate are registrated trademarks owned by Grundfos Management A S or Grundfos A S Denmark All rights reserved worldwide 96464310 0811 L CRN TL 01 0811 US Repl 0609 ...

Отзывы: