1. Limited warranty

Products manufactured by GRUNDFOS PUMPS CORPORATION 
(Grundfos) are warranted to the original user only to be free of 
defects in material and workmanship for a period of 24 months 
from date of installation, but not more than 30 months from date 
of manufacture. Grundfos' liability under this warranty shall be 
limited to repairing or replacing at Grundfos' option, without 
charge, F.O.B. Grundfos' factory or authorized service station, 
any product of Grundfos' manufacture. Grundfos will not be liable 
for any costs of removal, installation, transportation, or any other 
charges which may arise in connection with a warranty claim. 
Products which are sold but not manufactured by Grundfos are 
subject to the warranty provided by the manufacturer of said 
products and not by Grundfos' warranty. Grundfos will not be
liable for damage or wear to products caused by abnormal
operating conditions, accident, abuse, misuse, unauthorized 
alteration or repair, or if the product was not installed in
accordance with Grundfos' printed installation and operating 
instructions.
To obtain service under this warranty, the defective product must 
be returned to the distributor or dealer of Grundfos' products from 
which it was purchased together with proof of purchase and 
installation date, failure date, and supporting installation data. 
Unless otherwise provided, the distributor or dealer will contact 
Grundfos or an authorized service station for instructions. Any 
defective product to be returned to Grundfos or a service station 

must be sent freight prepaid; documentation supporting the
warranty claim and/or a Return Material Authorization must be 
included if so instructed.
GRUNDFOS WILL NOT BE LIABLE FOR ANY INCIDENTAL OR 
CONSEQUENTIAL DAMAGES, LOSSES, OR EXPENSES
ARISING FROM INSTALLATION, USE, OR ANY OTHER 
CAUSES. THERE ARE NO EXPRESS OR IMPLIED
WARRANTIES, INCLUDING MERCHANTABILITY OR FITNESS 
FOR A PARTICULAR PURPOSE, WHICH EXTEND BEYOND 
THOSE WARRANTIES DESCRIBED OR REFERRED TO 
ABOVE.
Some jurisdictions do not allow the exclusion or limitation of
incidental or consequential damages and some jurisdictions do 
not allow limit actions on how long implied warranties may last. 
Therefore, the above limitations or exclusions may not apply to 
you. This warranty gives you specific legal rights and you may 
also have other rights which vary from jurisdiction to jurisdiction.

2. Symbols used in this document

3. Permanent magnets

4. Product description

Grundfos CRN MAGdrive are 100 % leakage-free, sealless 
pumps. The motor torque is transmitted to the pump shaft by 
means of magnetic force.
Grundfos CRN MAGdrive pumps are suitable for the pumping of 
these liquids:
• Aggressive or corrosive liquids
• Toxic liquids
• Volatile liquids
• Obnoxious liquids
• Liquids without fibers and magnetic particles, as they may 

cause wear of the pump.

1.

Limited warranty

2

2.

Symbols used in this document

2

3.

Permanent magnets

2

4.

Product description

2

5.

Technical data

3

6.

Type key

3

7.

Mechanical installation

3

7.1

Installation of pump

3

7.2

Connection of sensor

3

8.

Electrical connection

3

8.1

Motor protection

3

9.

Start-up

4

10.

Maintenance

4

11.

Fault finding

4

12.

Service

4

12.1 Other documentation

4

13.

Disposal

4

Warning
Prior to installation, read these installation and 
operating instructions. Installation and operation 
must comply with local regulations and accepted 
codes of good practice.

Warning
The use of this product requires experience with 
and knowledge of the product.
Persons with reduced physical, sensory or mental 
capabilities must not use this product, unless 
they are under supervision or have been 
instructed in the use of the product by a person 
responsible for their safety.
Children must not use or play with this product.

Warning
If these safety instructions are not observed, it 
may result in personal injury!

Caution

If these safety instructions are not observed, it 
may result in malfunction or damage to the 
equipment!

Note

Note

Notes or instructions that make the job easier 
and ensure safe operation.

Persons with pacemaker or other magnet-sensi-
tive medical devices must not handle this pump. 
They must keep a distance of at least
3 feet from the MAGdrive, as there is a risk of 
influence from the magnetic fields of the pump.
Credit cards, computers, watches and other mag-
net-sensitive objects should not be kept close to 
the pump.

The pump contains powerful magnets that may 
pose a risk of personal injury when servicing the 
pump. The pump should therefore only be dis-
mantled and assembled by authorized personnel.

Grundfos.bk  Page 2  Tuesday, August 23, 2011  11:33 PM

Содержание CRN MAGdrive

Страница 1: ...GRUNDFOS INSTRUCTIONS CRN MAGdrive Installation and operating instructions ...

Страница 2: ...llow limit actions on how long implied warranties may last Therefore the above limitations or exclusions may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from jurisdiction to jurisdiction 2 Symbols used in this document 3 Permanent magnets 4 Product description Grundfos CRN MAGdrive are 100 leakage free sealless pumps The motor torque...

Страница 3: ... pump head 8 Electrical connection The pump must be installed as described in the installation and operating instructions of CR CRI CRN Pumps with motors of 25 and 30 Hp and 4 pole motors 1 5 Hp 1 1 kW and above must be started via a soft starter 8 1 Motor protection As minimum the motor must be connected to an effective elec tronic motor protection with instantaneous release when the max imum set...

Страница 4: ...the pump should be vented again Slowly loosen the air vent screw in the pump head Warning Pay attention to the direction of the vent hole to ensure that the escaping liquid does not cause injury to per sons or damage to the motor or other components 10 When liquid starts running out tighten the air vent screw securely 10 Maintenance The pump requires no maintenance if is has been installed accordi...

Страница 5: ...5 This page intentionally left blank ...

Страница 6: ...6 This page intentionally left blank ...

Страница 7: ...27 3400 Telefax 1 913 227 3500 Canada GRUNDFOS Canada Inc 2941 Brighton Road Oakville Ontario L6H 6C9 Phone 1 905 829 9533 Telefax 1 905 829 9512 México Bombas GRUNDFOS de México S A de C V Boulevard TLC No 15 Parque Industrial Stiva Aeropuerto Apodaca N L C P 66600 Phone 52 81 8144 4000 Telefax 52 81 8144 4010 ...

Страница 8: ...makes it possible Innovation is the essence The name Grundfos the Grundfos logo and the payoff Be Think Innovate are registrated trademarks owned by Grundfos Management A S or Grundfos A S Denmark All rights reserved worldwide 96464310 0811 L CRN TL 01 0811 US Repl 0609 ...

Отзывы: