Installation 

 

 

 

17 | 44 

B

A

_

T

D3

-A

K

0

0

0

en

_035

 

The installation location must be away from heat sources (e.g. 

washing machines, boilers and hot water pipes). 

The installation room must be provided with a floor drain. If none 
is available, an appropriate safety device has to be installed to 
avoid water damage. We recommend using a protectliQ:A. 

The installation site must be well accessible for maintenance 
purposes. 

4.2  Checking the scope of supply 

 

 

 

 

Item 

Designation 

Item 

Designation 

Water meter screw fittings 

Gaskets 

Fine filter pureliQ:K or pureliQ:KD 

Operation manual 

 

►  Check the scope of supply for completeness and possible 

damage. 

Содержание pureliQ:K

Страница 1: ...We understand water Filter Fine filter pureliQ K pureliQ KD Operation manual...

Страница 2: ...the copyright to this manual No part of this manual may be reproduced in any way without the written permission of Gr nbeck Wasseraufbereitung GmbH nor may any part be processed duplicated or dissemi...

Страница 3: ...components 14 3 3 Functional description 15 4 Installation 16 4 1 Requirements for the installation site 16 4 2 Checking the scope of supply 17 4 3 Installing the product 18 5 Start up 20 5 1 How to...

Страница 4: ...alist installers and owners users 1 3 Storage of documents Keep this manual and all other applicable documents so that they are available when needed Make sure that your specialist installer enters th...

Страница 5: ...sser V German Ordinance on General Conditions for the Supply of Water 1 5 Typographical conventions The following typographical conventions are used in this manual 1 5 1 Instructions Single step instr...

Страница 6: ...Lists List symbols used First list point level 1 First bullet point level 2 Second bullet point level 2 Second list point level 1 1 6 Validity of the manual This manual applies to the following produc...

Страница 7: ...er below in order to have the necessary data handy whenever necessary Item Designation Item Designation 1 Observe operation manual 2 SVGW mark of conformity registered 3 DVGW mark of conformity regist...

Страница 8: ...About this manual 8 44 BA_TD3 AK000en_035 Serial no ________________...

Страница 9: ...sequence may be water damage Only use genuine spare parts for maintenance or repair If unsuitable spare parts are used the warranty for your product will be void Comply with the hygiene instructions i...

Страница 10: ...oidance The following signal words are defined depending on the degree of danger and can be used in this document DANGER means that serious or fatal injuries will occur if the corresponding precaution...

Страница 11: ...g water for human consumption VDI 6023 Part 6 2 4 Responsibilities of the specialist installer Comply with the following instructions to ensure the proper and safe functioning of the product Only perf...

Страница 12: ...d in this manual Do not carry out any activities that are explicitly marked for a specialist installer Only use this product as intended Make sure that the required inspection and maintenance work is...

Страница 13: ...ure range The filters are not suitable for circulation water that is treated with chemicals They are neither suitable for oils greases solvents soaps and other lubricating media nor for the separation...

Страница 14: ...components Item Designation Item Designation 1 Water meter screw connection 2 Click connection flange 3 Pressure reducer handwheel 4 Month display 5 Pressure gauge 6 Support fabric 7 Filter element 8...

Страница 15: ...pure water outlet Thus foreign particles of 100 m in size are retained Depending on their size and weight the foreign particles either stick to the filter element or they fall straight down into the f...

Страница 16: ...806 2 and DIN 1988 200 in the cold water line downstream of the water meter and upstream of distribution lines or the devices to be protected Item Designation Item Designation 1 Shut off valve 4 1 Re...

Страница 17: ...available an appropriate safety device has to be installed to avoid water damage We recommend using a protectliQ A The installation site must be well accessible for maintenance purposes 4 2 Checking...

Страница 18: ...ding to DIN VDE 0100 540 Use suitable tools for assembly and be careful not to scratch the housing with your tool The transparent plastic film serves as transport and dirt protection We recommend leav...

Страница 19: ...ow direction given on site 3 Check the flow direction given on site 4 Rotate the click type connection flange to the position suitable for your flow direction marking on click type connection flange 5...

Страница 20: ...filter as far as it will go The filter is vented 3 Check the filter for leaks The filter is in operation 5 2 Setting the month display In order not to miss a maintenance date you can set the next date...

Страница 21: ...he pressure reducer is 4 bar You can change this value as follows 1 Open the withdrawal point 2 Set the desired after pressure on the handwheel for pressure reducer by turning it 3 Read off the measur...

Страница 22: ...When handing over the product proceed as follows 1 Inform the owner user how the filter works 2 Hand over all documents to the owner user for keeping 3 Use the manual to brief the owner user and answ...

Страница 23: ...n and replacement of the filter element Inspection and maintenance of a filter is prescribed in the DIN EN 806 5 standard Regular maintenance ensures trouble free hygienic operation A maintenance cont...

Страница 24: ...ng maintenance Owner user or specialist installer 6 3 Inspection According to DIN EN 806 5 the owner user has to inspect the filters every 2 months Check the installation for leaks refer to chapter 5...

Страница 25: ...Cleaning inspection maintenance 25 44 BA_TD3 AK000en_035 6 Unscrew the filter bell by hand You have uncovered the used filter element and can change it as described below 1 2...

Страница 26: ...hygienic reasons the new filter element must not be touched with bare hands 5 Slide the filter element in the foil over the support fabric 6 Pull off the foil downwards without touching the filter ele...

Страница 27: ...sk of inadequate hygiene It is essential to discard used filter elements Designation Order no 100 m filter element 2x 101 272e 6 6 Wearing parts NOTE Danger of damaging the system if unsuitable wearin...

Страница 28: ...s 6 7 1 Service kits for fine filter pureliQ K Item Designation Item Designation 1 Support fabric O ring 2 Support fabric 3 Filter cylinder 4 Cylinder O ring Designation consisting of Order no Recomme...

Страница 29: ...ng 3 Support fabric 4 Filter cylinder 5 Cylinder O ring 6 Pressure reducer Designation consisting of Order no Recommended replacement interval Service kit III Set of seals Support fabric Pressure redu...

Страница 30: ...n maintenance 30 44 BA_TD3 AK000en_035 6 8 Spare parts NOTE Risk of damaging the system when unsuitable spare parts are used Risk of functional impairment malfunctions and loss of warranty Only use ge...

Страница 31: ...ment is dirty Change the filter element Taste of the treated water negatively affected Inappropriately long period of non use standstill Draw off water for a few minutes Change the filter element Soli...

Страница 32: ...sal Do not dispose of the packaging the product and or the accessories with the domestic waste Comply with the applicable national regulations for disposal Make sure that the packaging the product and...

Страница 33: ...imensions and weights A Installation height up to centre of connection mm 235 B Installation length with without screw connection mm 185 100 182 100 191 100 C Min distance to wall mm 50 D Installation...

Страница 34: ...h 6 5 8 5 9 1 Pore size m 100 Largest smallest pore size m 120 80 Nominal pressure PN 16 General Water temperature C 5 30 Ambient temperature C 5 40 DVGW registration number pending SVGW certificate n...

Страница 35: ...d weights A Installation height up to centre of connection mm 235 B Installation length with without screw connection mm 185 100 182 100 191 100 C Min distance to wall mm 50 D Installation depth up to...

Страница 36: ...m h Flow rate as per DIN EN 1567 m h 2 3 3 6 5 8 KV value m h Pore size m 100 Largest smallest pore size m 120 80 Nominal pressure PN 16 General Water temperature C 5 30 Ambient temperature C 5 40 DV...

Страница 37: ...ding does not exceed the maximum specified value whichever value is lower Upper filtration fineness the number indicates the particle size of a material in m which passes through the filter under test...

Страница 38: ...Operation log 38 44 BA_TD3 AK000en_035 11 Operation log Product designation Fine filter pureliQ ____ Order no 101 ___ Serial no ________________ Date Work performed Signature...

Страница 39: ...Notes 39 44 BA_TD3 AK000en_035 Notes...

Страница 40: ...Notes 40 44 BA_TD3 AK000en_035 Notes...

Страница 41: ...Notes 41 44 BA_TD3 AK000en_035 Notes...

Страница 42: ...r element14 15 25 26 27 31 33 35 37 Filtration 13 I Inspection 12 23 24 Installation 9 11 12 16 19 24 M Maintenance 4 9 11 12 20 23 24 26 Malfunction 31 P Pressure reducer 13 14 15 21 29 S Service kit...

Страница 43: ......

Страница 44: ...Gr nbeck Wasseraufbereitung GmbH Josef Gr nbeck Str 1 89420 Hoechstaedt Germany For more Information go to www gruenbeck com 49 9074 41 0 49 9074 41 100 info gruenbeck com www gruenbeck com...

Отзывы: