Operation
GENO
-Multi BS
Order no. 004 523 950-gb Edited by: KONS-rjau-mrie G:\BA-523950-GB_KD-F.DOC
-CONFIDENTIAL-
F-9
2.4 Error memory
Code 245
The FIFO error memory covers the last 20 malfunctions including
the time stamp of how many operating hours ago the malfunction
occurred. The malfunction no. 20 lying furthest back is deleted
from the memory in each case when a new malfunction occurs.
Requirement: The control unit shows the basic display of irradi-
ance.
1.
Press keys + at the same time until the display
changes.
The installer level is active. The required menu must be selected
first. The numbers (000) flash.
These should be reset so that they
display the code for the menu to be edited.
The code for the level
required here is 245.
2.
Press key to count upwards until C.245 appears in the
display.
OR
Press key to count downwards until C.245 appears in
the display.
Hold down keys and so that the numbers run faster; press
the keys for fine adjustment.
3.
Press key to accept code 245.
Note:
In contrast to the Info level, it is possible in the error
memory to move backwards and forwards between the individual
parameters using keys and .
Index Parameter,
Unit
Note
1
1Ex
Latest error occurring (X hours ago)
Xh
2
2Ey
Second-latest error occurring (Y hours ago)
Yh
…
20 20Ez
Error occurring the longest time ago
(Z hours ago)
Zh
2.5 Displaying the software
version code 999
Display of the software version programmed into the control unit,
e.g. "u1.04".