Emptying
time
t
EZ
= 12
The emptying time t
EZ
of the
cartridge
is
12
months.
Number of lubrication strokes
C = 1
The number of lubrication strokes
is one (1) per outlet and per pump
cycle.
The default settings result in an emptying time t
EZ
(service life) for a full lubricant cartridge with
250 ml or 400 ml content of 12 months when using an LUB-V with one (1) outlet in the operating
mode empty time mode, provided that the LUB-V is permanently switched on and no special lu-
brication strokes were carried out, e.g. by the filling or quick check menu. The LUB-V calculates
a lubrication cycle time of approx. 5.2 hours when using a cartridge with 250 ml content and a
lubrication cycle time of approx. 3.3 hours when using a cartridge with 400 ml content. The lu-
brication cycle duration depends on the number of outlets of the present LUB-V and the selected
cartridge size.
If you use the LUB-V with one (1) lubricant outlet, a pump cycle of one lubrication stroke from
the one outlet is performed at the beginning of the lubrication cycle duration t
SZ
. If you use the
LUB-V with two (2) lubricant outlets, a pump cycle of one stroke per outlet is performed at the
beginning of the lubrication cycle duration. The lubrication cycle duration is doubled.
Determine whether the default settings are applicable to your application and whether the lu-
brication point is supplied with the correct amount of lubricant per time unit.
If this is the case, you can operate the LUB-V in the operating mode Empty time mode with the
default settings.
If this is
not
the case, change the value for the emptying time t
EZ
and/or the number of lubrication
strokes C per pump cycle PZ accordingly: This chapter explains how to make these changes.
To use the LUB-V, it must first be properly mounted and installed and then switched on. Moun-
ting is very simple and described in detail in Chap. 5; switching on is described in Chap. 6.3.1.
Definitions of the adjustable parameters for the emptying time t
EZ
and the number of lubrication
strokes C per pump cycle PZ and their respective permissible values:
t
EZ
:=
emptying time
in months (m).
The emptying time can be set between 1 | 2 | 3 | ... | 36 months.
C :=
number of lubrication strokes
during a pump cycle PZ.
The number of cycles c can be set between 1 | 2 | 3 | ... | 30 strokes.
Default settings Operating mode Empty time mode: