Prohibited methods of operation 

Operational  security  of  the  Lubricus  Lubrication  System  is  only  guaranteed  if  it 

is  operated  in  accordance  with  the 

operating instructions

. The limit values stated in the technical data must not be exceeded under any circumstances. 

 

General risk reference 

All components of the system are designed in accordance with the prevailing regulations of the construction 
of technical machines, in regards to operational safety and accident prevention.  Operation outside of these 

constraints  can  lead  to  dangers  for  the  user  respectively  third  persons  or  other  technical  facilities.  The 
Lubricus  Lubrication  System  therefore  may  fulfil  only  in 

technically  fault-free  condition

  its  intended  use. 

This may only be carried out under compliance of the safety regulations and the attention of the operator's 

manual. 
Therefore please 

regularly inspect

 the pump and its attachments for possible 

damage

 or 

leaks

Transport and storage 

Use suitable lifting gear for transport. 
Do not throw or expose the Lubricus Lubrication System to strong shock loads. 

Store the Lubricus Lubrication System 

in a cool and dry place to avoid corrosion of the system’s individual parts.

 

 

Pay attention to the current safety- and accident prevention instructions during the transport. Wear suitable 

protection equipment if necessary! 
 

Installation instruction 

The following conditions have to be satisfied during the installation of this Lubricus Lubrication System, thus it 
can  be  assembled,  with  other  parts,  to  a  complete  machine  without  affecting  the  safety  and  health  of 
humans. 

 

The housing of Lubricus should not be exposed to direct sunlight and/or radiant heat preventing the 

formation of condensation. 

 

Electrical connection

 

 

Have the electric power supply connected only by a trained electrician! 

 

Connection and wiring of the electric components should be done by an expert trained in this field. 

 

Check the voltage details with the existing power supply voltage! 

 

Maintenance /repair

 

Disconnect the voltage feed, before starting with 

maintenance or repair.

 

Maintenance and repair

 work may only be done with the system shut down. 

Check the surface temperature  of  Lubricus Lubrication  System,  due to danger of burning by radiant heat. 
Always wear heat-resistance gloves! Protect the system from activation during maintenance and repair work! 

 

 

 

 

Содержание Lubricus LUB-D1

Страница 1: ...version 04 2013 User Guide Lubricus Lubrication System LUB D1 LUB D2 LUB D3 LUB D4 24 VDC...

Страница 2: ...4 General safety information 4 Transport and storage 6 Function Principle 7 Communication Interface Connector PIN assignment 7 Installation instruction Pulse signals details 8 Functional problems err...

Страница 3: ...ning Lubricus Lubrication System is designed for use in normal industrial environment indoor as well as outdoor but is not suitable for mounting on moving equipment for example trucks Only use origina...

Страница 4: ...on System Other uses or uses beyond those described above cannot be considered to be in accordance with the regulations Extent of warranty Warranties concerning operating safety reliability and capaci...

Страница 5: ...be protected from touching The protection on moving or rotating parts must not be removed In case of leakages of dangerous media proper disposal not endangering environment and people must be ensured...

Страница 6: ...oads Store the Lubricus Lubrication System in a cool and dry place to avoid corrosion of the system s individual parts Pay attention to the current safety and accident prevention instructions during t...

Страница 7: ...inued PIN 4 relays the operating condition Connector PIN assignment connection to Lubicus Type D Output signal in case of empty lubricant reservoir PIN 4 generates an alternating high and low signal s...

Страница 8: ...UB C 4 LUB C 1 1 Activate 1 1 Activate 1 1 1 2 outlets will be served alternately and dispense equal quantities from both outlets Activate 2 1 Activate 2 1 2 2 outlets will be served alternately and d...

Страница 9: ...5cm 1 5cm outlet 2 2 10 x 0 15cm 1 5cm Modell LUB D 1 1 outlet 1 1 20 x 0 15 cm 3 0 cm outlet 1 2 closed outlet 2 1 20 x 0 15 cm 3 0 cm outlet 2 2 closed Functional problems Error messages faults The...

Страница 10: ...move it 4 Remove the empty cartridge 5 Remove protection from the new cartridge 6 Lubricate O Ring of the new cartridge slightly 7 Place the cartridge on the inlet 8 Place the pump upright on flat sur...

Страница 11: ...ight without lubricant ca 1120g Integrated Control micro processor controlled Pressure monitoring integrated electronic monitoring backpressure Level monitoring integrated reedcontact Connector M12 x...

Страница 12: ...en disposing lubricant the waste disposal instructions of the lubricant manufacturer must be observed Disposal of Lubricus Lubrication System observe the regional valid laws and regulations The empty...

Отзывы: